Luis Adolfo Cervantes

Dr. Luis Adolfo Cervantes

Universidad Inca Garcilaso de la Vega, Lima, Peru
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
ACAnn Carrillo-Marcos
Ann Carrillo-Marcos
GSGiuliany Salazar-Correa
Giuliany Salazar-Correa
LCLeonor Castro-Ramirez
Leonor Castro-Ramirez
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
CLCarlos López-Gurreonero
Carlos López-Gurreonero
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
The aim of this study was to assess the microhardness and surface roughness of bulk-fill resin composites treated with and without the application of an oxygen-inhibited layer (OIL) and a polishing system. This in vitro experimental study consisted of 72 resin composite blocks divided into three groups: Tetric N-Ceram Bulk Fill, Opus Bulk Fill APS, and Filtek Bulk Fill. Each resin composite group was further divided into two subgroups: with and without OIL control. Subsequently, surface roughness and microhardness were measured before and after polishing. A t-test was used to compare independent and related measures. For the intergroup comparison of variation before and after polishing, the Kruskal–Wallis test with Bonferroni post hoc was used considering a significance level of p < 0.05. When comparing surface roughness, significant differences were observed between Opus Bulk Fill resin composite with and without OIL control (p = 0.003) before polishing. The same occurred when comparing Tetric N-Ceram resin composite with and without OIL control (p = 0.039) after polishing. In addition, the surface roughness of Filtek Bulk Fill, Opus Bulk Fill, and Tetric N-Ceram Bulk Fill resin composites, with and without OIL control, decreased significantly after polishing (p < 0.001), while surface microhardness significantly increased (p < 0.05), with the exception of Opus Bulk Fill resin with OIL control (p = 0.413). In conclusion, OIL control and polishing significantly improved the surface roughness and surface microhardness of Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites. However, in the case of Opus Bulk Fill resin composite, only its surface roughness was significantly improved.

26 June 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
AGAndrea Gaviria-Martinez
Andrea Gaviria-Martinez
LCLeonor Castro-Ramirez
Leonor Castro-Ramirez
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
Luis Adolfo CervantesLuis Adolfo Cervantes
Luis Adolfo Cervantes
HCHernán Cachay-Criado
Hernán Cachay-Criado
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
Background: It has been demonstrated that dental restorations with rough surfaces can have several disadvantages such as pigment retention or plaque accumulation, which can facilitate caries formation, color variation, loss of brightness, degradation of restoration, among others. The present study aimed to assess surface roughness in bulk fill and conventional nanohybrid resins with and without polishing, controlling the oxygen inhibited layer. Methods: This in vitro and longitudinal experimental study consisted of 120 resin blocks of 6 mm diameter and 4 mm depth, divided into two groups: Bulk Fill (Tetric® N-Ceram Bulk-fill, Opus Bulk Fill APS, Filtek™ Bulk Fill) and conventional nanohybrid (Tetric® N-Ceram, Opallis EA2, Filtek™ Z250 XT). Each resin group was divided into two equal parts, placing glycerin only on one of them, in order to control the oxygen inhibited layer. Subsequently, the surface roughness was measured before and after the polishing procedure with Sof-Lex discs. The data were analyzed with the T-test for related measures, and for comparison between groups before and after polishing, the non-parametric Kruskal Wallis test with the Bonferroni post hoc was used, considering a significance level of p < 0.05. Results: Before polishing, the resin composites with the lowest surface roughness were Opus Bulk Fill APS (0.383 ± 0.186 µm) and Opallis EA2 (0.430 ± 0. 177 µm) with and without oxygen inhibited layer control, respectively; while after polishing, those with the lowest surface roughness were Opus Bulk Fill APS (0.213 ± 0.214 µm) and Tetric N-Ceram (0.097 ± 0.099 µm), with and without oxygen inhibited layer control, respectively. Furthermore, before and after polishing, all resins significantly decreased their surface roughness (p < 0.05) except Opus Bulk Fill APS resin with oxygen inhibited layer control (p = 0.125). However, when comparing this decrease among all groups, no significant differences were observed (p < 0.05). Conclusion: The Opus Bulk Fill APS resin with oxygen inhibited layer control presented lower surface roughness both before and after polishing, being these values similar at both times. However, after polishing the other bulk fill and conventional nanohybrid resins with and without oxygen inhibited layer control, the surface roughness decreased significantly in all groups, being this decrease similar in all of them.

4 December 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
KHKaren K. Hernández-Caba
Karen K. Hernández-Caba
AAAna S. Aliaga-Mariñas
Ana S. Aliaga-Mariñas
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
Luis Adolfo CervantesLuis Adolfo Cervantes
Luis Adolfo Cervantes
Background: The contraction presented by resin composites causes an increase in stress at the tooth-resin interface, causing micro-gaps that allow microleakage. This study aims to evaluate the degree of in vitro marginal microleakage in class II restorations with two bulk fill resin composites compared to a conventional nanohybrid resin composite. Methods: The present study was an in vitro experimental design. A total of 30 standardized class II cavities were prepared in 15 human molars (mesially and distally). These cavities were later distributed in 3 groups according to the type of resin. Groups A and B were restored with bulk fill resin composites (Filtek—3 M/ESPE and Tetric N-Ceram—Ivoclar/Vivadent respectively) in a single increment of 4 mm. Group C was restored with the Filtek Z350 XT – 3 M/ESPE resin composite and two increments of 2 mm. Later, the restorations were subjected to 10,000 thermocycles between 5 °C to 55 °C and immersed in a silver nitrate solution (1 M for 24 h). The crowns were then sectioned mesiodistally and observed under the stereomicroscope to determine the degree of marginal microleakage at the occlusal and cervical areas. The results were analyzed with the Kruskal–Wallis and the Mann–Whitney U statistical tests. Results: There were no statistically significant differences regarding the degree of microleakage between the three types of resin composites in the occlusal and cervical areas (p > 0.05). Similarly, there were no significant differences after comparing each resin type in its occlusal and cervical area (p > 0.05). Conclusion: Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites showed no statistically significant differences with the conventional nanohybrid resin composite Filtek Z350XT at both occlusal and cervical areas.

22 December 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
JZJorge Zamudio-Santiago
Jorge Zamudio-Santiago
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
Flor Magaly SantanderFlor Magaly Santander
Flor Magaly Santander
CLCarlos López-Gurreonero
Carlos López-Gurreonero
ACAlberto Cornejo-Pinto
Alberto Cornejo-Pinto
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
Background: Activated charcoal is a nanocrystalline form of carbon with a large specific surface area and high porosity in the nanometer range, having consequently the capacity to absorb pigments, chromophores, and stains responsible for tooth color change, while carbamide peroxide is unstable and breaks down immediately upon contact with tissue and saliva, first dissociating into hydrogen peroxide and urea and subsequently into oxygen, water, and carbon dioxide. Therefore, the aim of the present study was to assess the effect of 16% carbamide peroxide and activated-charcoal-based whitening toothpaste on enamel surface roughness in bovine teeth. Materials and Methods: The present experimental in vitro, longitudinal, and prospective study consisted of 60 teeth randomly distributed in six groups: A: artificial saliva, B: conventional toothpaste (Colgate Maximum Protection), C: whitening toothpaste with activated charcoal (Oral-B 3D White Mineral Clear), D: 16% carbamide peroxide (Whiteness Perfect 16%), E: 16% carbamide peroxide plus conventional toothpaste (Whiteness Perfect 16% plus Colgate Maximum Protection), and F: 16% carbamide peroxide plus whitening toothpaste with activated charcoal (Whiteness Perfect 16% plus Oral-B 3D White Mineral Clear). Surface roughness was assessed with a digital roughness meter before and after each treatment. For the statistical analysis, Student’s t test for related samples was used, in addition to the ANOVA test for one intergroup factor, considering a significance level of p < 0.05. Results: The surface roughness variation of bovine tooth enamel, before and after application of bleaching agent, was higher in groups of whitening toothpaste with activated charcoal (0.200 µm, Confidence Interval (CI): 0.105; 0.296 µm) and 16% carbamide peroxide plus whitening toothpaste with activated charcoal (0.201 µm, (CI): 0.092; 0.309 µm). In addition, bovine teeth treated with conventional toothpaste (p = 0.041), whitening toothpaste with activated charcoal (p = 0.001), and 16% carbamide peroxide plus whitening toothpaste with activated charcoal (p = 0.002) significantly increased their surface roughness values. On the other hand, significant differences were observed when comparing the variation in surface roughness between the application of artificial saliva (control) and the whitening toothpaste with activated charcoal (p = 0.031), and the 16% carbamide peroxide plus whitening toothpaste with activated charcoal (p = 0.030). Conclusion: The use of whitening toothpaste with activated charcoal and in combination with 16% carbamide peroxide significantly increased enamel surface roughness in bovine teeth.

1 March 2022 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
PDF file
EYEnrique Yarasca-Berrocal
Enrique Yarasca-Berrocal
JEJose Luis Huamani Echaccaya
Jose Luis Huamani Echaccaya
RTRita Tolmos-Valdivia
Rita Tolmos-Valdivia
LTLuis Tolmos-Regal
Luis Tolmos-Regal
CLCarlos López-Gurreonero
Carlos López-Gurreonero
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
Aim: The aim of this study was to evaluate the predictability and accuracy of the Short-Form Fonseca Anamnestic Index (SFAI) in relation to the modified Helkimo Index for the diagnosis of temporomandibular disorders (TMDs). Materials and Methods: A cross-sectional, prospective, and analytical predictive study was conducted in 240 students of a public institute of higher technological education in Ica, Peru during the months of February to May 2018. The SFAI of 10 closed questions and the Helkimo Index modified by Maglione (gold standard) were used as instruments to diagnose TMDs. For the analysis of concordance between both instruments, Cohen’s Kappa Index was applied. To evaluate the association according to gender and age group, Pearson’s chi-square test was used. For validity of the SFAI in relation to accuracy, sensitivity and specificity were calculated, and they were verified by receiver operating characteristics (ROC) to determine the best cutoff points (area under the curve [AUC]) considering a P value < 0.05. Regarding the predictability of the SFAI, the positive and negative predictive value was calculated by applying Bayes’ theorem. Results: The SFAI was highly significantly associated with the modified Helkimo Index according to gender (P < 0.001), age group (P < 0.001), and overall (P < 0.001) moderate overall agreement (k = 0.416; 95% confidence interval [CI] = 0.287–0.545); better concordance was obtained in individuals older than 20 years (k = 0.490, CI = 0.302–0.679) and women (k = 0.565, CI = 0.371–0.759). The ROC curve analysis of the SFAI showed good accuracy (0.852, CI = 0.800–0.905) and was highly significant (P < 0.001), with an optimal cutoff point of 17.5 and good sensitivity (80.10%) and specificity (74.36%). In addition, a very good positive predictive value (PPV) (94.15%) and a fair negative predictive value (NPV) (42.02%) were obtained. Conclusions: Although there was moderate concordance between the SFAI and the modified Helkimo Index for the diagnosis of TMDs, the SFAI obtained good accuracy in the overall analysis of sensitivity and specificity. In addition, it demonstrated a high predictive efficacy for detecting positive TMD cases, whereas its ability to rule out positive cases was fair.

7 January 2022 in European Journal of Dental Education
Verified
Journal Article
Open access
PDF file
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
LSLilliam Soto‐Castro
Lilliam Soto‐Castro
MCManuel Castro‐Mena
Manuel Castro‐Mena
SMSara Medrano‐Colmenares
Sara Medrano‐Colmenares
CLCarlos López‐Gurreonero
Carlos López‐Gurreonero
Luis Adolfo CervantesLuis Adolfo Cervantes
Luis Adolfo Cervantes
Background: Metalloproteinases are proteolytic enzymes that degrade dentin and periodontal collagen; therefore, it is of special interest that dental students know its mechanism of action and how its effects can be inhibited. Therefore, the aim of this research was to evaluate the level of knowledge about metalloproteinases in dental students close to graduate from three universities in Peruvian capital city.Materials and methods: In this analytical, observational, cross‐sectional and prospective study, 223 dental students close to graduate in three Peruvian universities were evaluated from September to November 2020. A questionnaire of 20 closed questions with three answers was validated and used to measure the level of general and dental knowledge about metalloproteinases. A logit model was used to evaluate the influence of the following variables: “gender” (X1), “type of university” (X2), “marital status” (X3) and “age group” (X4), in the knowledge levels of the students, considering a p‐value <.05.Results: Of the 223 dentistry students, it was obtained that the level of knowledge about metalloproteinases was predominantly low with 82.1%, (95% confidence interval (CI): 77.1%–87.1%) of the total. According to multivariate logistic regression analysis, "type of university" was the only variable that proved to have a significant influence (p = .022) on the level of knowledge about metalloproteinases with an odds ratio of (OR = 0.44; CI: 0.21–0.89), whilst the other variables "age group" (p > .05), "gender" (p = .058) and "marital status" (p = .114) were not considered influential factors.Conclusion: The majority of final year dental students in three Peruvian universities presented a low level of overall knowledge about metalloproteinases. In addition, private university students were 56% less likely to pass the subject knowledge test. On contrary, gender, age group and marital status did not significantly influence the level of knowledge of the students.