Alina Duta

Dr. Alina Duta

University of Craiova, Craiova, Dolj, Romania
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Stelian-Mihai-Sever PetrescuStelian-Mihai-Sever Petrescu
Stelian-Mihai-Sever Petrescu
MȚMihaela Jana Țuculină
Mihaela Jana Țuculină
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
ADAlina Duta
Alina Duta
ASAlex Ioan Sălan
Alex Ioan Sălan
IDIonela Teodora Dascălu
Ionela Teodora Dascălu
Cone beam computed tomography (CBCT) is a modern imaging technique that uses X-rays to investigate the structures of the dento-maxillary apparatus and obtain detailed images of those structures. The aim of this study was to determine a functional mathematical model able to evaluate the elastic force intensity on each bracket and tube type element and the ways in which those components act on the orthodontic system being used. To analyze a real orthodontic system, we studied the case of a 13-year-old female patient. To transfer geometric information from tomographic images, we used the InVesalius software. This software can generate three-dimensional reconstructions based on sequences and files in the DICOM format and was purchased from CBCT equipment. We analyzed and processed the geometries of the converted tissues in InVesalius using the Geomagic software. After using the Geomagic software, we exported the resulting model to the SolidWorks software used in computer-aided design. In this software, the model is transformed into a virtual solid. After making the geometric model, we analyzed the model using the Ansys Workbench software, which incorporates finite element analysis techniques. Following the simulations, we obtained result maps, which showed the complete mechanical behavior of the analyzed structures.

27 April 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MKMahmoud KATTA Katta
Mahmoud KATTA Katta
Stelian-Mihai-Sever PetrescuStelian-Mihai-Sever Petrescu
Stelian-Mihai-Sever Petrescu
LDLucian Paul Dragomir
Lucian Paul Dragomir
MPMihai Raul Popescu
Mihai Raul Popescu
RGRuxandra Voinea Georgescu
Ruxandra Voinea Georgescu
IDIonela Teodora Dascălu
Ionela Teodora Dascălu
The finite element method (FEM) is a computational method that can solve all biomechanical problems, including the field of orthodontics. The purpose of this virtual experimental study is to determine the behavior of a real orthodontic system subjected to different systems of loads. To analyze the real orthodontic system, we studied the case of a 21-year-old female patient. We used the InVesalius program, which can transform a set of DICOM-type images taken from cone beam computed tomography (CBCT) into three-dimensional structures. These structures were edited, modified, completed, and analyzed from a geometric point of view with the help of the Geomagic software. The final result of these operations must be a three-dimensional model made up of perfectly closed surfaces so that they can be transformed into virtual solids. The model consisting of perfectly closed surfaces is loaded into computer-aided design (CAD) programs. Bracket and tube components, as well as orthodontic wires, can be added to these models, similar to the analyzed patient’s tissues. When the model is complete and geometrically correct, it is exported to a program that uses FEM, such as Ansys Workbench. The simulation was performed for the forces of 0.5, 0.6, 0.7, 0.8, 0.9, and 1 N. The intention was to determine the behavior of the entire orthodontic system for these force values. After running the simulations, result maps were obtained that were composed of displacement, strain, and stress diagrams. It was also found that, in addition to the known rigidity, the orthodontic system has some elasticity due to the orthodontic wires, as well as the periodontal ligaments. Thus, a virtual analysis study can be carried out starting from a real patient with pre-treatment CBCT images and the virtual models of the bracket and tube elements and of the orthodontic wires.

7 October 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Stelian-Mihai-Sever PetrescuStelian-Mihai-Sever Petrescu
Stelian-Mihai-Sever Petrescu
ARAnne-Marie Rauten
Anne-Marie Rauten
MPMihai Popescu
Mihai Popescu
MPMihai Raul Popescu
Mihai Raul Popescu
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
BGBUCIU GABRIEL
BUCIU GABRIEL
The development of the finite element method (FEM) combined block polynomial interpolation with the concepts of finite difference formats and the variation principle. Because of this combination, the FEM overcomes the shortcomings of traditional variation methods while maintaining the benefits of current variation methods and the flexibility of the finite difference method. As a result, the FEM is an advancement above the traditional variation methods. The purpose of this study is to experimentally highlight the thermal behavior of two stomatognathic systems, one a control and the other presenting orthodontic treatment by means of a fixed metallic orthodontic appliance, both being subjected to several thermal regimes. In order to sustain this experimental research, we examined the case of a female subject, who was diagnosed with Angle class I malocclusion. The patient underwent a bimaxillary CBCT investigation before initiating the orthodontic treatment. A three-dimensional model with fully closed surfaces was obtained by using the InVesalius and Geomagic programs. Like the tissues examined in the patient, bracket and tube-type elements as well as orthodontic wires can be included to the virtual models. Once it is finished and geometrically accurate, the model is exported to an FEM-using program, such as Ansys Workbench. The intention was to study the behavior of two stomatognathic systems (with and without a fixed metallic orthodontic appliance) subjected to very hot food (70 °C) and very cold food (−18 °C). From the analysis of the obtained data, it was concluded that, following the simulations carried out in the presence of the fixed metallic orthodontic appliance, significantly higher temperatures were generated in the dental pulp.
1

12 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
ADAlina Duta
Alina Duta
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
DVDaniela Doina Vintila
Daniela Doina Vintila
BGBUCIU GABRIEL
BUCIU GABRIEL
NDNicolae Adrian Dina
Nicolae Adrian Dina
DCDaniel Cosmin Calin
Daniel Cosmin Calin
(1) Introduction: The changes in the joint morphology inevitably lead to prosthesis, but the hip pathology is complex. The hip arthroplasty is a therapeutic solution and can be caused, most frequently, by primary and secondary coxarthrosis due to or followed by traumatic conditions. The main aim of this study was to find the method of revision hip prosthesis that preserves as much bone material as possible and has sufficiently good mechanical strength. (2) Materials and Methods: In this study, in a first step, the two revision prostheses were performed on bone components taken from an animal (cow), and then, they were tested on a mechanical testing machine until the prostheses physically failed, and the force causing their failure was determined. (3) Results: These prostheses were then modelled in a virtual environment and tested using the finite element method (FEM) in order to determine their behaviour under loading from normal human gait. Displacement, strain, and stress maps were obtained. (4) Discussion: Discussions on hip revision prostheses, method, and theory analysis are presented at the end of the paper. (5) Conclusions: Important conclusions are drawn based on comparative analyses. The main conclusion shows that the both orthopaedic prostheses provide a very good resistance.

11 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Stelian-Mihai-Sever PetrescuStelian-Mihai-Sever Petrescu
Stelian-Mihai-Sever Petrescu
MPMihai Popescu
Mihai Popescu
MPMihai Raul Popescu
Mihai Raul Popescu
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
DIDumitru Ilie
Dumitru Ilie
ARAnne-Marie Rauten
Anne-Marie Rauten
The development of the finite element method (FEM) combined block polynomial interpolation with the concepts of finite difference formats and the variation principle. Because of this combination, FEM overcomes the shortcomings of traditional variation methods while maintaining the benefits of current variation methods and the flexibility of the finite difference method. As a result, FEM is an advancement above the traditional variation methods. The aim of the study is to experimentally determine the thermal behavior of two stomatognathic systems, one control and the other presenting orthodontic treatment by means of a fixed metallic orthodontic appliance, both being subjected to several thermal regimes. In order to carry out this experimental study, we examined the case of a female subject, who was diagnosed with Angle class I malocclusion. The patient underwent a bimaxillary CBCT investigation before initiating the orthodontic treatment. A three-dimensional model with fully closed surfaces was obtained by using the InVesalius and Geomagic programs. Like the tissues examined in the patient, bracket and tube-like components, as well as orthodontic wires, can be included to these models. Once it is finished and geometrically accurate, the model is exported to a FEM-using program, such as Ansys Workbench. The intention was to study the behavior of two stomatognathic systems (with and without a fixed metallic orthodontic appliance) subjected to very hot food (70 ⁰C) and very cold food (-18 ⁰C). From the analysis of the obtained data, it was concluded that, following the simulations carried out in the presence of the fixed metallic orthodontic appliance, significantly higher temperatures were generated in the dental pulp.

25 May 2023
Verified
Book Chapter
Open access
PDF file
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
ADAlina Duta
Alina Duta
GBGabriel Buciu
Gabriel Buciu
Daniela TarnitaDaniela Tarnita
Daniela Tarnita
DVDaniela Vintila
Daniela Vintila
In order to obtain a personalized three-dimensional model of a patient based on CT images, the InVesalius program was initially used, which performs the initial conversion of the analyzed tissues into a specific engineering file composed of the so-called “point cloud”. This “point cloud” was imported into the Geomagic program, in which, using reverse engineering techniques, the “point cloud” was initially transformed into elementary triangular surfaces. These primary geometric structures have been edited, transformed, adapted so that, in the end, perfectly closed surfaces are obtained. It was done in this way, both for the bone structure of the head, but also for the dental structure. These complex geometries were loaded into SolidWorks, where they were originally transformed into virtual solids. These geometric structures were loaded and assembled into SolidWorks and interference solids were removed. Finally, a customized three-dimensional model was obtained on which different normal or pathological situations can be analyzed using kinematic simulations or using the finite element method.