Wen Tsung Ho

Mr. Wen Tsung Ho

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
WFWen-Shuang Fan
Wen-Shuang Fan
SHShuan-Yu Huang
Shuan-Yu Huang
Hong-Thai NguyenHong-Thai Nguyen
Hong-Thai Nguyen
WHWen Tsung Ho
Wen Tsung Ho
WCWen-Hung Chao
Wen-Hung Chao
Hsiang-Chen WangHsiang-Chen Wang
Hsiang-Chen Wang
With the rapid development of display technology, related diseases of the human eye are also increasing day by day. Eye floaters are one of the diseases that affect humans. Herein, we present a functional ophthalmic dressing that can permeate the skin tissues of the eyes through oxygen and hydrogen to improve the symptoms of floaters. In clinical tests, the symptoms of sensory floaters improved in 28 patients, and the recovery rates of mild, moderate, and severe floaters were about 70%, 66.7%, and 83.3%, respectively.

24 April 2024 in IEEE Photonics Journal
Verified
Journal Article
Open access
Zhi Ting YeZhi Ting Ye
Zhi Ting Ye
STShen Fu Tseng
Shen Fu Tseng
STShang Xuan Tsou
Shang Xuan Tsou
WHWen Tsung Ho
Wen Tsung Ho
Glucose monitoring is critical for diabetes patients. However, invasive blood testing carries the risk of infection if wound care is not handled properly and non-invasive glucose testing devices are often bulky and not portable. Therefore, our study proposes the use of white light-emitting diode (LED) bulbs with different color temperatures as a light source. Additionally, ammonium metavanadate and sulfuric acid were used to prepare the detection solution instead of peroxidase to produce color, after which images were captured using a smartphone. The red, green, and blue (RGB) channels were then separated and converted into grayscale images. The average grayscale value changes in the images were analyzed to determine the linear relationship between glucose concentration and grayscale values, thus allowing for non-invasive quantitative glucose testing. When using a 3000K white LED bulb as the light source, the grayscale values of the RGB channels analyzed from the images exhibited a linear relationship with the glucose concentration at a 0.1–10 mM range. The regression equation for the red channel was y = −3.1184x+148.2, with a coefficient of determination (R 2 ) of 0.9165, a limit of detection (LOD) of 2.27 mM, and a limit of quantification (LOQ) of 6.88 mM. The proposed method of using white LED bulbs as a detection light source combined with image analysis can be used to determine whether glucose concentrations in blood, saliva, or tears are higher than normal, providing the advantages of rapid, highly sensitive, and non-invasive testing.

9 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WHWen Tsung Ho
Wen Tsung Ho
TYTsung-Hsun Yu
Tsung-Hsun Yu
WCWen-Hung Chao
Wen-Hung Chao
BWBao-Yen Wang
Bao-Yen Wang
YKYu-Yeh Kuo
Yu-Yeh Kuo
SYSkye Hsin-Hsien Yeh
Skye Hsin-Hsien Yeh
Hydrogen/oxygen-generating biomaterials, a new trend in regenerative medicine, generate and supply hydrogen/oxygen to increase the local levels of hydrogen/oxygen to support tissue healing and regeneration. In this study, we carefully defined a strategic plan to develop a gas-permeable layer suitable for use in sanitary products that is capable of supplying hydrogen or oxygen in situ using calcium hydroxides as chemical oxygen sources. In vitro physicochemical evaluations of hydrogen- and oxygen-generation efficiency were performed to determine the amount of hydrogen and oxygen produced. An in vivo permeation study was conducted to assess biological parameters, including blood oxygen (O2) and hydrogen (H+) levels. The stress hormone corticosterone and inflammation marker interleukin 6 (IL-6) were also quantified. The hydrogen/oxygen-generating patch (HOGP) continuously generated H+ or O2 for up to 12 h after activation by water. An in vivo evaluation showed blood H+ peaked at 2 h after application of the HOGP and then progressively decreased until the end of study (24 h), whereas oxygen content (O2(ct)) and oxygen saturation (SO2(SAT)) continuously increased up to 6 h. Hematological and electrolyte parameters did not significantly change compared to baseline. Wearing the stretch fabric used to secure the patch did not significantly increase serum corticosterone or interleukin 6 (IL-6) in the animals. This novel design of a hydrogen/oxygen-generating biomaterial for supplying topical H+/O2 may hold potential for increasing in situ or circulating H+/O2 levels to improve healthcare outcomes.