16 January 2024 in IEEE Journal of Selected Topics in Quantum Electronics
Albumin, a globular protein, is commonly used as an indicator of kidney damage when conducting invasive blood tests and non-invasive urine tests. Moreover, chemical methods that convert ultraviolet light to visible light require additional labeling steps to distinguish albumin from other proteins. In this study, to address labeling issue, a miniature colorimetric sensor (MCS) including the light source using a flip-chip (FC) ultraviolet C light emission diode (UVC-LED) and a green CsPbBr 3 quantum dot (QD) film emitting at 530 nm for converting the transmitting ultraviolet light through bovine serum albumin (BSA) and human serum albumin (HSA) to green fluorescence was developed. The proposed sensor detected BSA and HSA at a concentration range of 0.05 to 4.00 mg/mL, with coefficients of determination(R 2 ) of 0.9822 and 0.9850, limits of detection of 0.61 mg/mL and 0.56 mg/mL, and limits of quantitation of 2.02 mg/mL and 1.86 mg/mL, respectively. Additionally, the portable FC UVC-LEDs MCS offers reduced size and weight while maintaining detection linearity, compared to the conventional spectrometer. The fluorescence detection sensor using UVC-LED emitters and CsPbBr 3 QD film color convertors proposed herein provides an accurate, label-free, instantaneous and non-invasive real-time monitoring and quantification tool for albumin-associated disease diagnosis.
24 April 2024 in IEEE Photonics Journal
Glucose monitoring is critical for diabetes patients. However, invasive blood testing carries the risk of infection if wound care is not handled properly and non-invasive glucose testing devices are often bulky and not portable. Therefore, our study proposes the use of white light-emitting diode (LED) bulbs with different color temperatures as a light source. Additionally, ammonium metavanadate and sulfuric acid were used to prepare the detection solution instead of peroxidase to produce color, after which images were captured using a smartphone. The red, green, and blue (RGB) channels were then separated and converted into grayscale images. The average grayscale value changes in the images were analyzed to determine the linear relationship between glucose concentration and grayscale values, thus allowing for non-invasive quantitative glucose testing. When using a 3000K white LED bulb as the light source, the grayscale values of the RGB channels analyzed from the images exhibited a linear relationship with the glucose concentration at a 0.1–10 mM range. The regression equation for the red channel was y = −3.1184x+148.2, with a coefficient of determination (R 2 ) of 0.9165, a limit of detection (LOD) of 2.27 mM, and a limit of quantification (LOQ) of 6.88 mM. The proposed method of using white LED bulbs as a detection light source combined with image analysis can be used to determine whether glucose concentrations in blood, saliva, or tears are higher than normal, providing the advantages of rapid, highly sensitive, and non-invasive testing.
15 April 2024 in IEEE Sensors Journal
Detecting albumin levels quantitatively is challenging due to interference from other substances and lengthy reaction times. In this research, we proposed a lightweight paper sensor for real-time human serum albumin detection, utilizing imaging and spectroscopy techniques. By combining bromocresol green (BCG) with human serum albumin (HSA), we induced a structural change in BCG, resulting in protonation from C 21 H 14 Br 4 O 5 S to C 21 H 12 Br 4 O 5 2 -S, leading to a blue-green coloration. Subsequently, we applied this reagent to test paper for the reaction, utilized a smartphone camera for image detection, and performed spectrophotometric analyses. Our study presents a convenient, swift, and quantitative approach to measuring HSA concentration, initially accessible through a smartphone camera. Additionally, spectrophotometric analysis ensures precise quantification.