Ieva Šakinytė-Urbikienė

Dr. Ieva Šakinytė-Urbikienė

Life Sciences Center, Vilnius University, Vilnius, Vilniaus Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

11 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Julija RazumieneJulija Razumiene
Julija Razumiene
VGVidute Gureviciene
Vidute Gureviciene
IŠIeva Šakinytė-Urbikienė
Ieva Šakinytė-Urbikienė
LRLaurynas Rimsevicius
Laurynas Rimsevicius
VLValdas Laurinavicius
Valdas Laurinavicius
Thermally reduced graphene oxide (TRGO) is a graphene-based nanomaterial that has been identified as promising for the development of amperometric biosensors. Urease, in combination with TRGO, allowed us to create a mediator-free amperometric biosensor with the intention of precise detection of urea in clinical trials. Beyond simplicity of the technology, the biosensor exhibited high sensitivity (2.3 ± 0.1 µA cm−2 mM−1), great operational and storage stabilities (up to seven months), and appropriate reproducibility (relative standard deviation (RSD) about 2%). The analytical recovery of the TRGO-based biosensor in urine of 101 ÷ 104% with RSD of 1.2 ÷ 1.7% and in blood of 92.7 ÷ 96.4%, RSD of 1.0 ÷ 2.5%, confirmed that the biosensor is acceptable and reliable. These properties allowed us to apply the biosensor in the monitoring of urea levels in samples of urine, blood, and spent dialysate collected during hemodialysis. Accuracy of the biosensor was validated by good correlation (R = 0.9898 and R = 0.9982) for dialysate and blood, utilizing approved methods. The advantages of the proposed biosensing technology could benefit the development of point-of-care and non-invasive medical instruments.

1 April 2015 in Applied Surface Science
Verified
Journal Article
Closed access
JRJ. Razumiene
J. Razumiene
IŠIeva Šakinytė-Urbikienė
Ieva Šakinytė-Urbikienė
Jurgis BarkauskasJurgis Barkauskas
Jurgis Barkauskas
RBR. Baronas
R. Baronas

25 July 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
Julija RazumieneJulija Razumiene
Julija Razumiene
Damiana LeoDamiana Leo
Damiana Leo
VGVidute Gureviciene
Vidute Gureviciene
DRDalius Ratautas
Dalius Ratautas
JUSTINA GAIDUKEVIČJUSTINA GAIDUKEVIČ
JUSTINA GAIDUKEVIČ
IŠIeva Šakinytė-Urbikienė
Ieva Šakinytė-Urbikienė
Investigations of L-glutamate release in living organisms can help to identify novel L-glutamate-related pathophysiological pathways, since abnormal transmission of L-glutamate can cause many neurological diseases. For the first time, a nitrogen-modified graphene oxide (GO) sample (RGO) is prepared through a simple and facile one-pot hydrothermal reduction of GO in the presence of 20 wt.% of the dye malachite green and is used for amperometric biosensing. The biosensor demonstrates adequate stability and is easy to prepare and calibrate. The biosensor detects the current generated during the electrooxidation of hydrogen peroxide released in the L-glutamate that is converted to the alpha-ketoglutarate catalyzed by L-glutamate oxidase. The biosensor consists of a semipermeable membrane, with L-glutamate oxidase (EC 1.4.3.11) immobilized in albumin and RGO and the working Pt electrode. First, the basic version of the L-glutamate biosensor is examined in PBS to investigate its sensitivity, reliability, and stability. To demonstrate the applicability of the L-glutamate biosensor in the analysis of complex real samples, quantification of L-glutamate in bovine brain extract is performed and the accuracy of the biosensor is confirmed by alternative methods. The enhanced version of the L-glutamate biosensor is applied for L-glutamate release investigations in a newly developed strain of rats (DAT-knockout, DAT-KO).

19 November 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
IŠIeva Šakinytė-Urbikienė
Ieva Šakinytė-Urbikienė
MBMarius Butkevičius
Marius Butkevičius
VGVidute Gureviciene
Vidute Gureviciene
JSJonita Stankeviciute
Jonita Stankeviciute
RMRolandas Meskys
Rolandas Meskys
Julija RazumieneJulija Razumiene
Julija Razumiene
As electrode nanomaterials, thermally reduced graphene oxide (TRGO) and modified gold nanoparticles (AuNPs) were used to design bioelectrocatalytic systems for reliable D-tagatose monitoring in a long-acting bioreactor where the valuable sweetener D-tagatose was enzymatically produced from a dairy by-product D-galactose. For this goal D-fructose dehydrogenase (FDH) from Gluconobacter industrius immobilized on these electrode nanomaterials by forming three amperometric biosensors: AuNPs coated with 4-mercaptobenzoic acid (AuNP/4-MBA/FDH) or AuNPs coated with 4-aminothiophenol (AuNP/PATP/FDH) monolayer, and a layer of TRGO on graphite (TRGO/FDH) were created. The immobilized FDH due to changes in conformation and spatial orientation onto proposed electrode surfaces catalyzes a direct D-tagatose oxidation reaction. The highest sensitivity for D-tagatose of 0.03 ± 0.002 μA mM−1cm−2 was achieved using TRGO/FDH. The TRGO/FDH was applied in a prototype bioreactor for the quantitative evaluation of bioconversion of D-galactose into D-tagatose by L-arabinose isomerase. The correlation coefficient between two independent analyses of the bioconversion mixture: spectrophotometric and by the biosensor was 0.9974. The investigation of selectivity showed that the biosensor was not active towards D-galactose as a substrate. Operational stability of the biosensor indicated that detection of D-tagatose could be performed during six hours without loss of sensitivity.

29 June 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
RBRima Budvytyte
Rima Budvytyte
AMAkvile Milasiute
Akvile Milasiute
DVDalius Vitkus
Dalius Vitkus
Kęstutis StrupasKęstutis Strupas
Kęstutis Strupas
AGAiste Gulla
Aiste Gulla
Julija RazumieneJulija Razumiene
Julija Razumiene
Extracellular heat shock proteins (HSPs) mediate immunological functions and are involved in pathologies such as infection, stress, and cancer. Here, we demonstrated the dependence of an amount of HSP70 and HSP90 in serum vs. severity of acute pancreatitis (AP) on a cohort of 49 patients. Tethered bilayer lipid membranes (tBLMs) have been developed to investigate HSPs’ interactions with tBLMs that can be probed by electrochemical impedance spectroscopy (EIS). The results revealed that HSP70 and HSP90 interact via different mechanisms. HSP70 shows the damage of the membrane, while HSP90 increases the insulation properties of tBLM. These findings provide evidence that EIS offers a novel approach for the study of the changes in membrane integrity induced by HSPs proteins. Herein, we present an alternative electrochemical technique, without any immunoprobes, that allows for the monitoring of HSPs on nanoscaled tBLM arrangement in biologics samples such us human urine. This study demonstrates the great potential of tBLM to be used as a membrane based biosensor for novel, simple, and non-invasive label-free analytical system for the prediction of AP severity.