Jose Luis Colon Quintana

Dr. Jose Luis Colon Quintana

University of Maine, Orono, Maine, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Jose Luis Colon QuintanaJose Luis Colon Quintana
Jose Luis Colon Quintana
LSLucinda Slattery
Lucinda Slattery
JPJon Pinkham
Jon Pinkham
JKJoanna Keaton
Joanna Keaton
Roberto A Lopez-AnidoRoberto A Lopez-Anido
Roberto A Lopez-Anido
KSKeith Sharp
Keith Sharp
Large format polymer extrusion-based additive manufacturing has been studied recently due to its capacity for high throughput, customizable bead size and geometry, and ability to manufacture large parts. Samples from three fiber-filled amorphous thermoplastic materials 3D printed using a Masterprint 3X machine from Ingersoll Machine Tools were studied, along with their neat counterparts. Characterization techniques included thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and thermo-mechanical analysis (TMA). TGA results showed that the fillers decreased the degradation temperature for most of the materials investigated, with a 30 °C decrease for polycarbonate (PC) and a 12 °C decrease for polyethylene terephthalate glycol (PETG). For all the materials used, heat capacity increases with increasing temperature. Moreover, results show that a highly conductive filler increases the heat capacity. In contrast, a material with a lower conductivity decreases the heat capacity indicated in the 15.2% and 2.54% increase for acrylonitrile butadiene styrene (ABS) and PC and a 27.68% decrease for PETG. The TMA data show that the printed bead exhibits directional properties consistent with an orthotropic material. Smaller strains and coefficient of thermal expansion (CTE) were measured along the bead direction and across the bead compared to the through bead thickness showing that fillers are predominantly oriented in the bead direction, which is consistent with the literature. CTE values through bead thickness and neat material are similar in magnitude, which corresponds to the CTE of the matrix material. The experimental results serve to characterize the effect of fiber filler on the part thermal strains in three principal directions and two-part locations during the extrusion and bead deposition of large-format polymer extrusion-based additive manufacturing technologies.

17 October 2018 in Polymer Composites
Verified
Journal Article
Closed access
PDF file
Jose Luis Colon QuintanaJose Luis Colon Quintana
Jose Luis Colon Quintana
THTobias Heckner
Tobias Heckner
ACAchim Chrupala
Achim Chrupala
JPJesse Pollock
Jesse Pollock
SGSebastian Goris
Sebastian Goris
Tim OsswaldTim Osswald
Tim Osswald

1 August 2019 in Polymer Testing
Verified
Journal Article
Closed access
JPJohn Puentes
John Puentes
Jose Luis Colon QuintanaJose Luis Colon Quintana
Jose Luis Colon Quintana
ACAlexander Chaloupka
Alexander Chaloupka
NRNatalie Rudolph
Natalie Rudolph
TOTim A. Osswald
Tim A. Osswald

30 September 2024 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
Jose Luis Colon QuintanaJose Luis Colon Quintana
Jose Luis Colon Quintana
STScott Tomlinson
Scott Tomlinson
Roberto A Lopez-AnidoRoberto A Lopez-Anido
Roberto A Lopez-Anido
The thermomechanical and viscoelastic properties of a glass fiber polyethylene terephthalate glycol (GF/PETG) continuous unidirectional (UD) tape were investigated using differential scanning calorimetry (DSC), thermomechanical analysis (TMA), and dynamic mechanical analysis (DMA). This study identified five operational conditions based on the Army Regulation 70-38 Standard. The DSC results revealed a glass transition temperature of 78.0 ± 0.3 °C, guiding the selection of temperatures for TMA and DMA tests. TMA provided the coefficient of thermal expansion in three principal directions, consistent with known values for PETG and GF materials. DMA tests, including strain sweep, temperature ramp, frequency sweep, creep, and stress relaxation, defined the material’s linear viscoelastic region and temperature-dependent properties. The frequency sweep indicated an increased modulus with rising frequency, identifying several natural frequency modes. Creep and stress relaxation tests showed time-dependent behavior, with strain increasing under higher loads and stress decreasing over time for all tested input values. Viscoelastic models fitted to the data yielded R2 values of 0.99, demonstrating good agreement. The study successfully measured thermomechanical and viscoelastic properties across various conditions, providing insights into how temperature influences the material’s mechanical response under extreme conditions.

25 February 2022 in International Polymer Processing
Verified
Journal Article
Closed access
Jose Luis Colon QuintanaJose Luis Colon Quintana
Jose Luis Colon Quintana
TOTim Osswald
Tim Osswald
The work explores the fundamentals of the softening process for amorphous materials expanding on the work presented by Stammers and Beek (Stammers, E. and Beek, W.J. (1969). The melting of a polymer on a hot surface. Polym. Eng. Sci. 9). The pressure induced melt removal process was studied in detail. The process, although fundamental, allows for an understanding of the phase transition of materials during the fused filament fabrication (FFF) process. Experimental results were analyzed using state-of-the-art equipment. A total of four materials were tested. PVC and PC are amorphous materials, and PA6 and PP are semi-crystalline materials. A setup was built to allow the application of a constant force. The resulting melt film was analyzed using computed tomography technology. The experimental results were compared with numerical simulation results originating from COMSOL Multiphysics and the analytical solution derived by Stammers and Beek. Rheological and thermo-mechanical tests were used to find the softening temperature of amorphous materials. Results showed a straightforward transition for the melting temperature of semi-crystalline materials and softening temperature of amorphous materials. It is suggested that for amorphous materials, the glass transition temperature can be used as the softening temperature (T s = T g ). When comparing all three results (experimental, analytical, and numerical), values are within the same range and magnitude. A good approximation was achieved for PA6 and PVC, which have semi-crystalline and amorphous structures, respectively. Results provide insights into the phase transition process and phase change mechanisms during the extrusion of materials in the fused filament fabrication process.

28 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Jose Luis Colon QuintanaJose Luis Colon Quintana
Jose Luis Colon Quintana
STScott Tomlinson
Scott Tomlinson
Roberto A Lopez-AnidoRoberto A Lopez-Anido
Roberto A Lopez-Anido
The thermomechanical and viscoelastic properties of a glass fiber polyethylene terephthalate glycol (GF/PETG) continuous unidirectional (UD) tape were investigated using differential scanning calorimetry (DSC), thermo-mechanical analysis (TMA), and dynamic mechanical analysis (DMA). The study identified five operational conditions based on Army Regulation 70-38 Standard. The DSC results revealed a glass transition temperature of 78.0 ± 0.3°C, guiding the selection of temperatures for TMA and DMA tests. TMA provided the coefficient of thermal expansion in three principal directions, consistent with known values for PETG and GF materials. DMA tests, including strain sweep, temperature ramp, frequency sweep, creep, and stress relaxation, defined the linear viscoelastic region and temperature-dependent properties of the material. The frequency sweep indicated an increase in modulus with rising frequency, identifying several natural frequency modes. Creep and stress relaxation tests showed time-dependent behavior, with strain increasing under higher loads and stress decreasing over time for all tested input values. Viscoelastic models fitted to the data yielded R² values of 0.99, demonstrating good agreement. The study successfully measured thermo-mechanical and viscoelastic properties across various conditions, providing insights into how temperature influences the material's mechanical response under extreme conditions.