Pierluigi Reali

Dr. Pierluigi Reali

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
Stefania CoelliStefania Coelli
Stefania Coelli
ACAlessandra Calcagno
Alessandra Calcagno
CCChiara Maria Cassani
Chiara Maria Cassani
FTFederico Temporiti
Federico Temporiti
PRPierluigi Reali
Pierluigi Reali
Anna Maria BianchiAnna Maria Bianchi
Anna Maria Bianchi

15 September 2021 in Brain-Computer Interfaces
Verified
Journal Article
Closed access
MKMichael Thomas Knierim
Michael Thomas Knierim
CBChristoph Berger
Christoph Berger
PRPierluigi Reali
Pierluigi Reali
Observing brain activity in real life offers exciting possibilities like the support of physical health, mental well-being, and thought-controlled interaction modalities. The development of such applications is, however, strongly impeded by low accessibility to research-grade neural data and a lack of easy-to-use and comfortable sensors. To overcome these challenges, we present the cost-effective adaptation of concealed around-the-ear EEG electrodes (cEEGrids) to the open-source OpenBCI EEG signal acquisition platform. The system combines publicly available electronic components with 3D-printed parts, forming an easily replicable recording system for prolonged use and flexible application development. To demonstrate the system’s feasibility, experimentally induced changes in visual stimulation and mental workload are replicated. Lastly, a novel application area is investigated, the observation of flow experiences through observation of temporal Alpha power changes. Support for a link between temporal Alpha power and flow is found, indicating an efficient engagement of verbal-analytic reasoning with intensified flow levels.

8 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MKMichael Thomas Knierim
Michael Thomas Knierim
MBMartin Bleichner
Martin Bleichner
PRPierluigi Reali
Pierluigi Reali
Wearable electroencephalography (EEG) has the potential to improve everyday life through brain–computer interfaces (BCI) for applications such as sleep improvement, adaptive hearing aids, or thought-based digital device control. To make these innovations more practical for everyday use, researchers are looking to miniaturized, concealed EEG systems that can still collect neural activity precisely. For example, researchers are using flexible EEG electrode arrays that can be attached around the ear (cEEGrids) to study neural activations in everyday life situations. However, the use of such concealed EEG approaches is limited by measurement challenges such as reduced signal amplitudes and high recording system costs. In this article, we compare the performance of a lower-cost open-source amplification system, the OpenBCI Cyton+Daisy boards, with a benchmark amplifier, the MBrainTrain Smarting Mobi. Our results show that the OpenBCI system is a viable alternative for concealed EEG research, with highly similar noise performance, but slightly lower timing precision. This system can be a great option for researchers with a smaller budget and can, therefore, contribute significantly to advancing concealed EEG research.

13 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
PRPierluigi Reali
Pierluigi Reali
RLRiccardo Lolatto
Riccardo Lolatto
Stefania CoelliStefania Coelli
Stefania Coelli
GTGabriella Tartaglia
Gabriella Tartaglia
Anna Maria BianchiAnna Maria Bianchi
Anna Maria Bianchi
The increasingly widespread diffusion of wearable devices makes possible the continuous monitoring of vital signs, such as heart rate (HR), heart rate variability (HRV), and breath signal. However, these devices usually do not record the “gold-standard” signals, namely the electrocardiography (ECG) and respiratory activity, but a single photoplethysmographic (PPG) signal, which can be exploited to estimate HR and respiratory activity. In addition, these devices employ low sampling rates to limit power consumption. Hence, proper methods should be adopted to compensate for the resulting increased discretization error, while diverse breath-extraction algorithms may be differently sensitive to PPG sampling rate. Here, we assessed the efficacy of parabola interpolation, cubic-spline, and linear regression methods to improve the accuracy of the inter-beat intervals (IBIs) extracted from PPG sampled at decreasing rates from 64 to 8 Hz. PPG-derived IBIs and HRV indices were compared with those extracted from a standard ECG. In addition, breath signals extracted from PPG using three different techniques were compared with the gold-standard signal from a thoracic belt. Signals were recorded from eight healthy volunteers during an experimental protocol comprising sitting and standing postures and a controlled respiration task. Parabola and cubic-spline interpolation significantly increased IBIs accuracy at 32, 16, and 8 Hz sampling rates. Concerning breath signal extraction, the method holding higher accuracy was based on PPG bandpass filtering. Our results support the efficacy of parabola and spline interpolations to improve the accuracy of the IBIs obtained from low-sampling rate PPG signals, and also indicate a robust method for breath signal extraction.

24 January 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GTGiulia Tacchino
Giulia Tacchino
Stefania CoelliStefania Coelli
Stefania Coelli
PRPierluigi Reali
Pierluigi Reali
MGManuela Galli
Manuela Galli
Anna Maria BianchiAnna Maria Bianchi
Anna Maria Bianchi
Objective: In the electroencephalogram (EEG) the quadratic phase coupling (QPC) phenomenon indicates the presence of non-linear interactions among brain rhythms that could affect the interpretation of their physiological meaning. We propose the use of the bicoherence as a QPC quantification method to understand the nature of brain rhythm interplay. Methods: We firstly provide a simulation study to show under which condition of signal to noise ratio (SNR) the bicoherence is a reliable QPC quantifier and how to interpret the results. Secondly, in the light of the simulation results, we applied the bicoherence analysis to real EEG data acquired on thirteen volunteers during a cue-paced reaching motor task to quantify coupling and decoupling between mu and beta rhythms. An inter-trial averaging procedure was adopted in order to allow the correct calculation of the bicoherence during a motor task. Results: Simulations demonstrated that SNR has a strong impact on the correct quantification of bicoherence and that a reliable detection of QPC is possible when the SNR is favorable (>-5 dB). Results from EEG data demonstrated a QPC between mu and beta rhythms during the resting state and its fading during movement planning and execution, providing valuable information for the interpretation of their dynamics. Conclusion: The bicoherence was proven to be an effective tool for the investigation of coupling between the sensorimotor rhythms during all the phases of a motor task. This was assessed in relation to the physiological changing of the SNR characterizing the frequency components of interest.

1 August 2021 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
PRPierluigi Reali
Pierluigi Reali
CPCaterina Piazza
Caterina Piazza
GTGiulia Tacchino
Giulia Tacchino
LSLetizia Songia
Letizia Songia
Sarah NazzariSarah Nazzari
Sarah Nazzari
Anna Maria BianchiAnna Maria Bianchi
Anna Maria Bianchi
Objective. The respiratory sinus arrhythmia (RSA) is a well-known marker of vagal activity that can be exploited to measure stress changes. RSA is usually estimated from heart rate variability (HRV). This study aims to compare the RSA obtained with three widely adopted methods showing their strengths and potential pitfalls. Approach. The three methods are tested on 69 healthy preschoolers undergoing a stressful protocol, the strange situation procedure (SSP). We compare the RSA estimated by the Porges method, the univariate autoregressive (AR) spectral analysis of the HRV signal, and the bivariate AR spectral analysis of HRV and respirogram signals. We examine RSA differences detected across the SSP episodes and correlation between the estimates provided by each method. Main results. The Porges and the bivariate AR approaches both detected significant differences (i.e. stress variations) in the RSA measured across the SSP. However, the latter method showed higher sensitivity to stress changes induced by the procedure, with the mean RSA variation between baseline and first separation from the mother (the most stressful condition) being significantly different among methods: Porges, −17.5%; univariate AR, −18.3%; bivariate AR, −23.7%. Moreover, the performances of the Porges algorithm were found strictly dependent on the applied preprocessing. Significance. Our findings confirm the bivariate AR analysis of the HRV and respiratory signals as a robust stress assessment tool that does not require any population-specific preprocessing of the signals and warn about using RSA estimates that neglect breath information in more natural experiments, such as those involving children, in which respiratory frequency changes are extremely likely.