Michael Thomas Knierim

Dr. Michael Thomas Knierim

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2017
Verified
Book Chapter
Closed access
PDF file
MKMichael Thomas Knierim
Michael Thomas Knierim
RRRaphael Rissler
Raphael Rissler
VDVerena Dorner
Verena Dorner
AMAlexander Maedche
Alexander Maedche
CWChristof Weinhardt
Christof Weinhardt

16 December 2020 in IEEE Transactions on Affective Computing
Verified
Journal Article
Closed access
RRRaphael Rissler
Raphael Rissler
MNMario Nadj
Mario Nadj
MLMaximilian Xiling Li
Maximilian Xiling Li
NLNico Loewe
Nico Loewe
MKMichael Thomas Knierim
Michael Thomas Knierim
AMAlexander Maedche
Alexander Maedche
The focal role of flow in promoting desirable outcomes in companies, such as increased employees' well-being and performance, led scholars to study flow in the context of work. However, current measurement approaches which assess flow via self-report scales after task execution are limited due to obtrusiveness and a lack of real-time support. Hence, new measurement approaches must be created to overcome these limitations. In this paper, we use cardiac features (heart rate variability; HRV) and a Random Forest classifier to distinguish high and low flow. Our results from a large-scale lab experiment with 158 participants and a field study with nine participants reveal, that with HRV features alone, flow-classifiers can be built with an accuracy of 68.5% (lab) and 70.6% (field). Our research contributes to the challenge of developing a less obtrusive, real-time measurement method of flow based on physiological features and to investigate flow from a physiological perspective. Our findings may serve as foundation for future work aiming to build physio-adaptive systems which can improve employee's performance. For instance, these systems could ensure that no notifications are forwarded to employees while the system is 'sensing' flow.

15 September 2021 in Brain-Computer Interfaces
Verified
Journal Article
Closed access
MKMichael Thomas Knierim
Michael Thomas Knierim
CBChristoph Berger
Christoph Berger
PRPierluigi Reali
Pierluigi Reali
Observing brain activity in real life offers exciting possibilities like the support of physical health, mental well-being, and thought-controlled interaction modalities. The development of such applications is, however, strongly impeded by low accessibility to research-grade neural data and a lack of easy-to-use and comfortable sensors. To overcome these challenges, we present the cost-effective adaptation of concealed around-the-ear EEG electrodes (cEEGrids) to the open-source OpenBCI EEG signal acquisition platform. The system combines publicly available electronic components with 3D-printed parts, forming an easily replicable recording system for prolonged use and flexible application development. To demonstrate the system’s feasibility, experimentally induced changes in visual stimulation and mental workload are replicated. Lastly, a novel application area is investigated, the observation of flow experiences through observation of temporal Alpha power changes. Support for a link between temporal Alpha power and flow is found, indicating an efficient engagement of verbal-analytic reasoning with intensified flow levels.

1 December 2023 in MIS Quarterly
Verified
Journal Article
Closed access
MNMario Nadj
Mario Nadj
RRRaphael Rissler
Raphael Rissler
MAMarc Adam
Marc Adam
MKMichael Thomas Knierim
Michael Thomas Knierim
MLMaximilian X. Li
Maximilian X. Li
RRRené Riedl
René Riedl
Flow, the holistic sensation people experience when they act with total involvement, is a known driver for desired work outcomes like task performance. However, the increasing ubiquity of IT at work can disrupt employees’ flow. Thus, the impact of IT-mediated interruptions on flow warrants more attention in research and practice. We conducted a NeuroIS laboratory experiment focusing on a typical office work task—an invoice matching task (i.e., matching customer payments to invoices). We manipulated interruption frequency (low, high) and content relevance (irrelevant, relevant) to study the impact of interruptions on self-reported flow, its dimensions, and high-frequency heart rate variability (HF-HRV; calculated from electrocardiography recordings) as a proxy for parasympathetic nervous system (PNS) activation. We found that content relevance moderated the relationship between interruption frequency and self-reported flow and that these results vary along flow dimensions. Content relevance also moderated the relationship between interruption frequency and PNS activation. Furthermore, self-reported flow was positively associated with both perceived and objective task performance, while PNS activation was not related to either performance measure. Lastly, we found no relationship between PNS activation (measured by HF-HRV) and self-reported flow, contributing to an important debate in the NeuroIS literature on whether physiological evidence constitutes an alternative or a complement to self-reports. Overall, our findings indicate that frequent interruptions are not harmful per se. Rather, considering content relevance is critical for a more comprehensive understanding of the effects on self-reported flow, its dimensions, and the underlying physiology.

8 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MKMichael Thomas Knierim
Michael Thomas Knierim
MBMartin Bleichner
Martin Bleichner
PRPierluigi Reali
Pierluigi Reali
Wearable electroencephalography (EEG) has the potential to improve everyday life through brain–computer interfaces (BCI) for applications such as sleep improvement, adaptive hearing aids, or thought-based digital device control. To make these innovations more practical for everyday use, researchers are looking to miniaturized, concealed EEG systems that can still collect neural activity precisely. For example, researchers are using flexible EEG electrode arrays that can be attached around the ear (cEEGrids) to study neural activations in everyday life situations. However, the use of such concealed EEG approaches is limited by measurement challenges such as reduced signal amplitudes and high recording system costs. In this article, we compare the performance of a lower-cost open-source amplification system, the OpenBCI Cyton+Daisy boards, with a benchmark amplifier, the MBrainTrain Smarting Mobi. Our results show that the OpenBCI system is a viable alternative for concealed EEG research, with highly similar noise performance, but slightly lower timing precision. This system can be a great option for researchers with a smaller budget and can, therefore, contribute significantly to advancing concealed EEG research.

3 March 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
MKMichael Thomas Knierim
Michael Thomas Knierim
CZChristian Zimny
Christian Zimny
GIGabriel Ivucic
Gabriel Ivucic
TRTobias Röddiger
Tobias Röddiger
By tracking changes in brain activity, researchers are constantly working to revolutionise human-technology interaction. Unfortunately, such brain-computer interfaces still face limitations in terms of wearability, making large-scale data collection difficult. While gel-based wearable solutions exist, validated dry electrode systems are needed for practical everyday use. In this article, two experiments with 50 participants and 146 recordings were conducted in laboratory and field settings to compare the wearability and performance of two dry-electrode EEG systems: the Open ExG headphones and the OpenBCI Ultracortex full-head EEG. Our results show that the headphone EEG is perceived as more wearable, has equal signal quality and recording reliability when set up by a trained experimenter in the lab, and shows reliable performance in a relevant application scenario: classification of cognitive load levels across four tasks. Field evaluations further validate these results through reliable load monitoring across recording sessions, after self-setup by study participants at home. While some limitations remain for wider field use of dry-electrode headphone EEG, we highlight necessary and achievable improvements for future system and study designs for real-world use.