Jianmin Ye

Jianmin Ye


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2024 in Nano Today
Verified
Journal Article
Closed access
JYJianmin Ye
Jianmin Ye
YFYueyue Fan
Yueyue Fan
GNGaoli Niu
Gaoli Niu
BZBaoli Zhou
Baoli Zhou
YKYong Kang
Yong Kang
XJXiaoyuan Ji
Xiaoyuan Ji

14 December 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QGQi Guo
Qi Guo
JYJianmin Ye
Jianmin Ye
CWChao Wang
Chao Wang
XLXiao Liang
Xiao Liang
The sensitivity distribution of the Electromagnetic Tomography (EMT) system based on Tunneling Magneto Resistance (TMR) is quite different from the traditional coil measurement EMT system due to the change of detection sensor. The sensitivity of the TMRs-EMT system is higher only near the TMR sensors, but lower at other locations in the region of interest, which results in more serious ill-conditioned problem of image reconstruction. Focusing on the ill-conditioned problem, the Landweber algorithm is optimized by using an appropriate weight and an appropriate relaxation strategy in this paper. By verifying the consistency of variation of spectral radius of iterative matrix and variation of condition number for Landweber method, a new weight matrix is introduced for the general Landweber method to reduce the condition number. On this basis, an optimal relaxation factor is determined based on the principle of minimizing the spectral radius of the newly derived iterative matrix. By comparing the imaging results of the new method with the Landweber with a relaxation factor of 1, it can be seen that the average correlation coefficient with the new approach for the five models used in this paper is 0.8466, which is much higher than 0.7633 of the Landweber with a relaxation factor of 1. Meanwhile, the proposed method has a faster imaging speed. The convergence analysis of the two methods shows that the new relaxation factor determination strategy can overcome the semi-convergence problem of Landweber.

10 June 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CWChao Wang
Chao Wang
SZShuai Zhang
Shuai Zhang
YLYadong Li
Yadong Li
LJLin Jia
Lin Jia
JYJianmin Ye
Jianmin Ye
Electrostatic tomography (EST) has been widely used in gas-solids two-phase flows to measure particle velocity in many industrial processes. However, EST is a passive measurement technique and this results in rare independent measurements compared with other tomographic modalities. In this paper, an electrostatic direct velocity tomography (EDVT) method is proposed to increase the number of independent measurements and to improve the accuracy of velocity estimation. For a two-plane electrostatic sensor, the cross-correlation (CC) velocities between the electrodes from the two planes at different circumferential positions can represent the particle velocities in different regions. Firstly, the CC velocities between the electrodes on different planes are calculated and used as new measurements. In this way, the number of independent measurements of a 16-electrode EST sensor can be easily increased from 16 to 120. Secondly, by analyzing the relationship between the CC velocities and the particle charge and particle velocity distribution, a CC sensitivity matrix is established. Finally, a tomographic model to represent the velocity distribution of charged particles can be established based on the new measurements and CC sensitivity matrix. Simulation and experimental results show that the velocity distribution reconstructed by EDVT can represent the particle velocity distribution in the pipeline, and is promising to provide a method to study the mechanism of gas-solids two-phase flows.

10 June 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JYJianmin Ye
Jianmin Ye
WYWuqiang Yang
Wuqiang Yang
CWChao Wang
Chao Wang
Electrical capacitance tomography (ECT) has been developed for imaging permittivity distribution of two-phase flows in a pipe or vessel with high temporal resolution. The spatial resolution of ECT is relatively low due to its soft-field, ill-posed and ill-conditioned nature. So far, there is no comprehensive analysis on spatial resolution of ECT for complex two-phase flows. To systematically assess the merits of ECT, two-dimensional (2D) modeling is carried out based on fluid-field and electrostatic-field coupling simulation for liquid-solids two-phase flows. The real permittivity distribution and the corresponding capacitance measurements can be obtained simultaneously. The effect of the number of electrodes, the mesh used for reconstruction and the initialization method for Landweber iteration algorithm on image quality is investigated. In terms of the correlation coefficient between the reconstructed permittivity distribution and the real permittivity distribution obtained from the coupling simulation model, the accuracy and stability of reconstructed images are quantitatively evaluated. Furthermore, the sensitivity matrices and point spread functions (PSF) calculated without capacitance measurements are used to compare the performance of ECT sensors and validate the results with capacitance measurements from the coupling simulation. The two methods with and without capacitance measurements are used to evaluate the change in spatial resolution of ECT with different number of electrodes.

20 September 2016 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
MMMingxu Mao
Mingxu Mao
JYJianmin Ye
Jianmin Ye
HWHaigang Wang
Haigang Wang
JZJiaolong Zhang
Jiaolong Zhang
WYWuqiang Yang
Wuqiang Yang
Electrical capacitance tomography (ECT) is an imaging technique for measuring the permittivity change of materials. Using a multi-plane ECT sensor, three-dimensional (3D) distribution of permittivity may be represented. In this paper, three excitation strategies, including single-electrode excitation, dual-electrode excitation in the same plane, and dual-electrode excitation in different planes are investigated by numerical simulation and experiment for two three-plane ECT sensors with 12 electrodes in total. In one sensor, the electrodes on the middle plane are in line with the others. In the other sensor, they are rotated 45° with reference to the other two planes. A linear back projection algorithm is used to reconstruct the images and a correlation coefficient is used to evaluate the image quality. The capacitance data and sensitivity distribution with each measurement strategy and sensor model are analyzed. Based on simulation and experimental results using noise-free and noisy capacitance data, the performance of the three strategies is evaluated.

5 July 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SWShengnan Wang
Shengnan Wang
JYJianmin Ye
Jianmin Ye
YYYunjie Yang
Yunjie Yang
Measurement of oil-gas two-phase flow parameters such as Gas Void Fraction (GVF) and phase distribution plays a vital role in oil and gas industries. To quantitatively evaluate the performance of Electrical Capacitance Tomography (ECT) for measuring the complex dynamic oil-gas two-phase flows, a three-dimensional fluid dynamics-electrostatic field coupling model (3D-FECM) is proposed in this paper. Coupling simulation are carried out with a 12-electrode ECT sensor. Utilizing the 3D-FECM, the dynamic oil-gas two-phase flows and instantaneous ECT measurements are simultaneously obtained. Two GVF measurement approaches, i.e. the capacitance-based method and the image-based method, are used to calculate GVF. The permittivity distribution is reconstructed by using Linear Back Projection (LBP) and Landweber iteration. The capacitances with signal-noise ratios (SNRs) of 40 and 60 dB are generated for comparison and verification. Evaluation results show that the structural similarity between the ground truth and the reconstructed images using noise-free data by Landweber iteration are better than 0.765, while those by LBP are higher than 0.754, the noise with SNR of 60 dB has no obvious effect on the performance of image reconstruction, and the full-scale error of the image-based GVF prediction using 60 dB noisy data is within -0.82% to +6.09%, slightly better than that of the capacitance-based GVF results (i.e. −1.16% to +7.63%).