The onset of rotating stall and surge in compressors limits the operating range of aero-engines. Accurately predicting the key features during these events is critical in the engine design process. In this paper, a three-dimensional computational model for transient simulation of multi-stage axial compressors during stall is proposed. The kinetic equations describing the dynamic process of the compression system are constructed, with a 3D through-flow model for the compression part and a 1D gas collector model for the outlet part. The calculation of the source term is performed using the developed body-force model, which realizes the correlation between the deviation angle and the loss coefficient with the inlet parameters in various flow regions. Validated on a single-stage compressor and a single-rotor fan, the results show that the method is capable of capturing the stall and surge features correctly and that the three-dimensional structure of the stall cell can be captured. In addition, this model could be used for the analysis of the surge load, which is significant for the structural integrity of the compressor.
It is well known that variations in stagger angle between rotor blades affect compressor performance. In this paper, the stagger angle of blade No. 8 is increased or decreased by six degrees for non-uniformity, and the influence of rotor non-uniformity caused by the change in only one blade stagger angle on the performance and stability of the compressor is investigated. The experimental results show that whether the local rotor stagger angle increases or decreases, the compressor stability will deteriorate. If the stagger angle of blade No. 8 is reduced by six degrees, the flow coefficient at the stall point increases by 8.5%. If the stagger angle of blade No. 8 is increased by six degrees, the flow coefficient at the stall point increases by 1.5%. The reason for the deterioration of compressor stability caused by the local non-uniform rotor stagger angle is explored. When the stagger angle of rotor blade No. 8 deviates from the designed state, the load of blade No. 8 and the surrounding blades will change. The load on rotor blade No. 8 increases when the stagger angle decreases. In the near-stall condition, blade No. 8 becomes the “dangerous blade” that triggers the stall. As the stagger angle of rotor blade No. 8 increases, the load on blade No. 8 decreases. However, the load on blade No. 9 increases due to flow redistribution and blade No. 9 becomes a “dangerous blade” that triggers stall. The “dangerous blade” caused by the non-uniformity of stagger angle is the direct reason for the advance of the compressor rotating stall.
To make measurement of end-wall flow between blade rows in a compact multistage configuration possible, a miniature L-shaped five-hole probe was employed in this paper. This compact tip structure, realized by laser-printing instead of the conventional machining technique, reduces the blockage effect of this intrusive measurement on the flow and ensures high spatial resolution. The zonal method is introduced to extend the usable flow angle range up to 60 degrees. A local least-squares interpolation technique is utilized to acquire flow angle and static/total pressure. In order to improve accuracy for the points located at the sector boundary, the overlap region method is included in the interpolation. Additional test data indicate that the maximum error in flow angle is nearly within 1 degree, and the maximum errors of total pressure and static pressure are 0.56% and 1.9% respectively. The application in a low-speed multistage axial compressor indicates that the zonal method can decrease the number of points exceeding the measurable flow range and is of great significance for the end-wall flow measurement, especially for the near-stall condition. Compared with the traditional method, the proportion of available data for the near-stall state measurement was increased by 18% by using the zonal method.