Christoph Schukro

Prof. Dr. Christoph Schukro

Department of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2019 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Open access
PDF file
CSClemens Steinwender
Clemens Steinwender
PLP. Lercher
P. Lercher
CSChristoph Schukro
Christoph Schukro
HBHermann Blessberger
Hermann Blessberger
GPG. Prenner
G. Prenner
MSMarkus Stuehlinger
Markus Stuehlinger
Background: Cardiac pacing has been shown to improve quality of life and prognosis of patients with bradycardia for almost 60 years. The latest innovation in pacemaker therapy was miniaturization of generators to allow leadless pacing directly in the right ventricle. There is a long history and extensive experience of leadless ventricular pacing in Austria. However, no recommendations of national or international societies for indications and implantation of leadless opposed to transvenous pacing systems have been published so far. Results: A national expert panel of skilled implanters gives an overview on the two utilized leadless cardiac pacing systems and highlights clinical advantages as well as current knowledge of performance and complication rates of leadless pacing. Furthermore, a national consensus for Austria is presented, based on recent studies and current know-how, specifically including indications for leadless pacing, management of infection, suggestions for qualification, and training of the operators and technical standards. Conclusions: Leadless pacing systems can be implanted successfully with a low complication rate, if suggestions for indications and technical requirements are followed. Condensed An overview of the two utilized leadless cardiac pacing systems is given, specifically highlighting clinical advantages as well as current knowledge of performance and complication rates. Furthermore, a national consensus for Austria is presented, specifically including indications for leadless pacing, management of infection, and suggestions for qualification and technical standards.

1 September 2021 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Open access
ICIuliana Coti
Iuliana Coti
CSChristoph Schukro
Christoph Schukro
FDFitim Drevinja
Fitim Drevinja
THThomas Haberl
Thomas Haberl
AKAlexandra Kaider
Alexandra Kaider
MAMartin Andreas
Martin Andreas
The implantation of rapid-deployment aortic valves may interfere with the conduction system of the heart. This study evaluates the occurrence and predictive factors of conduction anomalies in patients undergoing surgical aortic valve replacement (SAVR) with a rapid-deployment balloon-expandable bioprosthesis in a single-center, real-world experience. Between May 2010 and April 2019, 700 consecutive patients were included in a prospective, ongoing database with a longitudinal follow-up preoperatively, at discharge, and at 3 months, 1 year, 3 years, and 5 years postoperatively. Thirty-seven patients (5.3%) had a permanent pacemaker at baseline and were excluded from further analysis, leaving 663 patients for analysis. Assessment of conduction anomalies was performed by electrocardiography (ECG) monitoring and repeated 12-lead ECG during the hospital stay and at postoperative follow-ups. Preoperatively, 126 patients (19.0%) presented with different conduction disturbances. New permanent pacemaker implantation (PPI) occurred in 61 patients during the first 14 days (cumulative incidence, 9.4%). The indication for PPI was complete atrioventricular block in 47 cases (77%). Preoperative conduction anomalies, such as right bundle branch block, as well as operative characteristics (concomitant procedures) were found to be independent predictors for new PPI. One-year survival was 98% in patients with new early PPI and 96% in those without new early PPI (P = .60). The PPI rate was in the range of previous reports for rapid-deployment prostheses. PPI did not have a significant influence on short- to intermediate-term survival. Case selection with exclusion of patients presenting with baseline conduction disturbances may decrease the rate of new PPIs after SAVR with rapid-deployment balloon-expandable bioprostheses.

1 September 2013 in International Journal of Cardiology
Verified
Journal Article
Closed access
CSChristoph Schukro
Christoph Schukro
LLLukas Leitner
Lukas Leitner
JSJohannes Siebermair
Johannes Siebermair
TPThomas Pezawas
Thomas Pezawas
GSGünter Stix
Günter Stix
HSHerwig Schmidinger
Herwig Schmidinger

1 October 2010 in International Journal of Cardiology
Verified
Journal Article
Closed access
CSChristoph Schukro
Christoph Schukro
TBThomas Berger
Thomas Berger
GSGünter Stix
Günter Stix
TPThomas Pezawas
Thomas Pezawas
JKJohannes Kastner
Johannes Kastner
HSHerwig Schmidinger
Herwig Schmidinger

1 September 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
CSChristoph Schukro
Christoph Schukro
SPStefan B. Puchner
Stefan B. Puchner

24 June 2015 in Clinical Research in Cardiology
Verified
Journal Article
Closed access
PDF file
TPThomas Pezawas
Thomas Pezawas
RRRobin Ristl
Robin Ristl
CSChristoph Schukro
Christoph Schukro
HSHerwig Schmidinger
Herwig Schmidinger