1 September 2021 in The Journal of Thoracic and Cardiovascular Surgery
The implantation of rapid-deployment aortic valves may interfere with the conduction system of the heart. This study evaluates the occurrence and predictive factors of conduction anomalies in patients undergoing surgical aortic valve replacement (SAVR) with a rapid-deployment balloon-expandable bioprosthesis in a single-center, real-world experience. Between May 2010 and April 2019, 700 consecutive patients were included in a prospective, ongoing database with a longitudinal follow-up preoperatively, at discharge, and at 3 months, 1 year, 3 years, and 5 years postoperatively. Thirty-seven patients (5.3%) had a permanent pacemaker at baseline and were excluded from further analysis, leaving 663 patients for analysis. Assessment of conduction anomalies was performed by electrocardiography (ECG) monitoring and repeated 12-lead ECG during the hospital stay and at postoperative follow-ups. Preoperatively, 126 patients (19.0%) presented with different conduction disturbances. New permanent pacemaker implantation (PPI) occurred in 61 patients during the first 14 days (cumulative incidence, 9.4%). The indication for PPI was complete atrioventricular block in 47 cases (77%). Preoperative conduction anomalies, such as right bundle branch block, as well as operative characteristics (concomitant procedures) were found to be independent predictors for new PPI. One-year survival was 98% in patients with new early PPI and 96% in those without new early PPI (P = .60). The PPI rate was in the range of previous reports for rapid-deployment prostheses. PPI did not have a significant influence on short- to intermediate-term survival. Case selection with exclusion of patients presenting with baseline conduction disturbances may decrease the rate of new PPIs after SAVR with rapid-deployment balloon-expandable bioprostheses.
22 May 2020 in Transplant International
Background The aim was to evaluate the association of molecular‐level human leukocyte antigen (HLA) mismatching with post‐transplant graft survival, rejection and cardiac allograft vasculopathy (CAV). Methods We retrospectively analysed all primary cardiac transplant recipients between 01/1984‐06/2016. 1,167 patients fulfilled inclusion criteria and had HLA typing information available. In 312 donor‐recipient pairs, typing at serological split antigen level was available. We used the Epitope MisMatch Algorithm to calculate the number of amino acid differences in antibody‐verified HLA eplets (amino acid mismatch‐load (AAMM)) between donor and recipient. Results Patients with a higher HLA‐DR AAMM load had inferior 1‐year graft survival (hazard ratio [HR], 1.14; 95% confidence interval [CI], 1.01‐1.28). The HLA‐AB AAMM load showed no impact on graft survival. In the subgroup with available split‐level information, we observed an inferior graft survival for a higher HLA‐DR AAMM load 3 months after transplantation (HR, 1.22; 95% CI, 1.04‐1.44) and a higher risk for rejection for an increasing HLA‐AB (HR, 1.70; 95% CI, 1.29‐2.24) and HLA‐DR (HR, 1.32; 95% CI, 1.09‐1.61) AAMM load. No impact on the development of CAV was found. Conclusions Molecular‐level HLA mismatch analysis could serve as a tool for risk stratification after heart transplantation and might take us one step further into precision medicine.
24 February 2018 in Indian Journal of Thoracic and Cardiovascular Surgery
The era of intracorporal continuous flow pumps has initiated significant success of left ventricular assist device (LVAD) surgery. However, median sternotomy has been the only surgical approach for implantation over many years. During the last decade, less-invasive access ways gained popularity. Within this review, we describe our own clinical experience in minimally invasive ventricular assist device (VAD) surgery and summarize the current scientific literature on this topic.
1 January 2017 in The Thoracic and Cardiovascular Surgeon
Objectives: Micro-emboli are detectable as high intensity transient signals (HITS) with Doppler ultrasound in different clinical conditions including patients with left ventricular assist devices (LVAD). In LVAD patients HITS represent micro-emboli of mostly gaseous nature. The cause of their formation, however, has not been determined. Methods: From June 2014 to September 2016 LVAD patients were systematically screed for HITS in the LVAD outflow graft by transthoracic echocardiography. The occurrence of HITS was then correlated with pump thrombus formation (PT) and non-thrombotic outflow graft occlusion. Results: HITS were detected in the outflow graft of 20 LVAD patients (Thoratec Heartmate II n = 12, Heartware HVAD n = 8). HITS correlated with PT in 14 patients (Heartmate II n = 7, HVAD n = 7) and non-thrombotic outflow graft stenosis in 6 patients (Heartmate II n = 5, HVAD n = 1). Patients with PT either underwent thrombolysis (n = 7), pump exchange (n = 2), LVAD weaning (n = 1) or no treatment if no hard clinical treatment indication was present (n = 5). In PT patients HITS disappeared after successful thrombolysis or pump exchange. Of note, pump thrombus formation or non-thrombotic outflow graft stenosis could be macroscopically assured at the time of transplant in the remaining patients. Conclusion: HITS detection by transthoracic echocardiography identifies patients with pump thrombus formation and non-thrombotic outflow graft occlusion and might develop as a very sensitive screening tool for pump pathology and hypocoagulation monitoring.
23 January 2013 in The Thoracic and Cardiovascular Surgeon
Objective: A median sternotomy is the standard incision for left ventricular assist device (LVAD) implantation. There are some theoretical advantages of avoiding a median sternotomy in LVAD patients including better right ventricular protection, improved pulmonary function and faster recovery. The present study was designed to evaluate a novel, minimally invasive sternotomy sparing technique for LVAD implantation. Methods: From February 2012 to September 2012 10 patients (mean age 55.5 ± 11.1yrs., 90% male, ischemic heart disease 70%, prior cardiac surgery 10%) with terminal heart failure (Intermacs level 1: 30%, level 2 10%, level 3 40%, level 4 – 7 20%) underwent minimally invasive isolated sternotomy sparing LVAD implantation (Heartware® HVAD n = 9, Thoratect® HMII n = 1). Surgical access was established by a left minithoracotomy directly over the apex, the outflow graft was tunneled to the aorta intrapericardially in all but redo cases. The aortic outflow anastomosis was performed via a right minithoracotomy in the 2nd intercostal space. Circulatory support for LVAD implantation was performed using CPB or ECMO. Results: Sternotomy sparing LVAD implantation was feasible in all patients with no need for conversions. Thirty-day and in-hospital mortality was 0%. Median time on respirator was 2.2 ± 3.4 days, overall in-hospital stay was 32.6 ± 8.5 days. One patient (10%) died during follow-up from pump thrombus formation. One patient underwent surgical revision for postoperative bleeding (retroperitoneal haematoma). We observed no permanent neurological deficits and relevant infections. Conclusion: Minimally invasive sternotomy sparing left ventricular assist device implantation is feasible and safe. The very encouraging results obtained in this initial series justify a broad application of this technique.