Woosub Song

Dr. Woosub Song


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLSeung Seok Lee
Seung Seok Lee
WSWoosub Song
Woosub Song
ECEun Seo Choi
Eun Seo Choi
We designed and fabricated a telecentric f-theta imaging lens (TFL) to improve the imaging performance of spectral domain optical coherence tomography (SD-OCT). By tailoring the field curvature aberration of the TFL, the flattened focal surface was well matched to the detector plane. Simulation results showed that the spot in the focal plane fitted well within a single pixel and the modulation transfer function at high spatial frequencies showed higher values compared with those of an achromatic doublet imaging lens, which are commonly used in SD-OCT spectrometers. The spectrometer using the TFL had an axial resolution of 7.8 μm, which was similar to the theoretical value of 6.2 μm. The spectrometer was constructed so that the achromatic doublet lens was replaced by the TFL. As a result, the SD-OCT imaging depth was improved by 13% (1.85 mm) on a 10 dB basis in the roll-off curve and showed better sensitivity at the same depth. The SD-OCT images of a multi-layered tape and a human palm proved that the TFL was able to achieve deeper imaging depth and better contrast. This feature was seen very clearly in the depth profile of the image. SD-OCT imaging performance can be improved simply by changing the spectrometer’s imaging lens. By optimizing the imaging lens, deeper SD-OCT imaging can be achieved with improved sensitivity.

2 December 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
YZYUCHEN ZHENG
YUCHEN ZHENG
MOMin-Hee Oh
Min-Hee Oh
WSWoosub Song
Woosub Song
KKKi-Hyun Kim
Ki-Hyun Kim
ISIn-Hee Shin
In-Hee Shin
JCJin-Hyoung Cho
Jin-Hyoung Cho
Enamel cracks generated in the anterior teeth not only affect the function but also the aesthetics of the teeth. Chair-side tooth enamel crack detection is essential for clinicians to formulate treatment plans and prevent related dental disease. This study aimed to develop a dental imaging system using a near-IR light source to detect enamel cracks and to investigate the relationship between anterior enamel cracks and age in vivo. A total of 68 subjects were divided into three groups according to their age: young, middle, and elderly. Near-infrared radiation of 850 nm was used to identify enamel cracks in anterior teeth. The results of the quantitative examination showed that the number of enamel cracks on the teeth increased considerably with age. For the qualitative examination, the results indicated that there was no significant relationship between the severity of the enamel cracks and age. So, it can be concluded that the prevalence of anterior cracked tooth increased significantly with age in the young and middle age. The length of the anterior enamel cracks tended to increase with age too; however, this result was not significant. The silicon charge-coupled device (CCD) with a wavelength of 850 nm has a good performance in the detection of enamel cracks and has very good clinical practicability.

26 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
H.M.S.S. HerathH.M.S.S. Herath
H.M.S.S. Herath
NVNuwan Madusanka Vithanage
Nuwan Madusanka Vithanage
ECEun Seo Choi
Eun Seo Choi
WSWoosub Song
Woosub Song
RCRYUNGKEE CHANG
RYUNGKEE CHANG
BLByeong-il Lee
Byeong-il Lee
This study introduces a framework for estimating the optical scattering properties of thin-film phantoms using a custom-built Spectral-Domain Dental Optical Coherence Tomography (DEN-OCT) system operating within the 780–900 nm spectral range. The purpose of this work was to assess the performance of this system. The system exhibited high depth-resolved imaging performance with an axial resolution of approximately 16.30 µm, a signal-to-noise ratio of about 32.4 dB, and a 6 dB sensitivity roll-off depth near 2 mm, yielding an effective imaging range of 2.5 mm. Thin-film phantoms with controlled optical characteristics were fabricated and analyzed using Beer–Lambert and diffusion approximation models to evaluate attenuation behavior. Samples representing different tissue analogs demonstrated distinct scattering responses: one sample showed strong scattering similar to hard tissues, while the others exhibited lower scattering and higher transmission, resembling soft-tissue properties. Spectrophotometric measurements at 840 nm supported these trends through characteristic transmittance and reflectance profiles. While homogeneous samples conformed to analytical models, the highly scattering sample deviated due to structural non-uniformity, requiring Monte Carlo simulation to accurately describe photon transport. OCT A-scan analyses fitted with exponential decay models produced attenuation coefficients consistent with spectrophotometric data, confirming the dominance of scattering over absorption. The integration of OCT imaging, optical modeling, and Monte Carlo simulation establishes a reliable methodology for quantitative scattering estimation and demonstrates the potential of the developed DEN-OCT system for advanced dental and biomedical imaging applications. The innovation of this work lies in the integration of phantom-based optical calibration, multi-model scattering analysis, and depth-resolved OCT signal modeling, providing a validated pathway for quantitative parameter extraction in dental OCT applications.

25 April 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TPThi-Ngot Pham
Thi-Ngot Pham
WSWoosub Song
Woosub Song
HKHyejin Kim
Hyejin Kim
JJJae Hyun Jung
Jae Hyun Jung
Suhyun ParkSuhyun Park
Suhyun Park
HKHyun Wook Kang
Hyun Wook Kang
Understanding the residual tattoo ink in skin after laser treatment is often critical for achieving good clinical outcomes. The current study aims to investigate the feasibility of a light-emitting diode (LED)-assisted CMOS camera to estimate the relative variations in tattoo contrast after the laser treatment. Asian mice were tattooed using two color inks (black and red). The LED illumination was a separate process from the laser tattoo treatment. Images of the ink tattoos in skin were acquired under the irradiation of three different LED colors (red, green, and blue) for pre- and post-treatment. The degree of contrast variation due to the treatment was calculated and compared with the residual tattoo distribution in the skin. The black tattoo demonstrated that the contrast consistently decreased after the laser treatment for all LED colors. However, the red tattoo showed that the red LED yielded an insignificant contrast whereas the green and blue LEDs induced a 30% (p < 0.001) and 26% (p < 0.01) contrast reduction between the treatment conditions, respectively. The proposed LED-assisted CMOS camera can estimate the relative variations in the image contrast before and after the laser tattoo treatment.