Nuwan Madusanka Vithanage

Dr. Nuwan Madusanka Vithanage

Pukyong National University, Busan, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
H.M.S.S. HerathH.M.S.S. Herath
H.M.S.S. Herath
HHH. M. K. K. M. B. Herath
H. M. K. K. M. B. Herath
NVNuwan Madusanka Vithanage
Nuwan Madusanka Vithanage
BLByeong-il Lee
Byeong-il Lee
Medical image quality assessment (MIQA) is vital in medical imaging and directly affects diagnosis, patient treatment, and general clinical results. Accurate and high-quality imaging is necessary to make accurate diagnoses, efficiently design treatments, and consistently monitor diseases. This review summarizes forty-two research studies on diverse MIQA approaches and their effects on performance in diagnostics, patient results, and efficiency in the process. It contrasts subjective (manual assessment) and objective (rule-driven) evaluation methods, underscores the growing promise of machine intelligence and machine learning (ML) in MIQA automation, and describes the existing MIQA challenges. AI-powered tools are revolutionizing MIQA with automated quality checks, noise reduction, and artifact removal, producing consistent and reliable imaging evaluation. Enhanced image quality is demonstrated in every examination to improve diagnostic precision and support decision making in the clinic. However, challenges still exist, such as variability in quality and variability in human ratings and small datasets hindering standardization. These must be addressed with better-quality data, low-cost labeling, and standardization. Ultimately, this paper reinforces the need for high-quality medical imaging and the potential of MIQA with the power of AI. It is crucial to advance research in this area to advance healthcare.

6 January 2020 in Current Medical Imaging
Verified
Journal Article
Closed access
BCBoo-Kyeong Choi
Boo-Kyeong Choi
NVNuwan Madusanka Vithanage
Nuwan Madusanka Vithanage
HCHeung-Kook Choi
Heung-Kook Choi
JSJae-Hong So
Jae-Hong So
CKCho-Hee Kim
Cho-Hee Kim
DPDeekshitha Prakash
Deekshitha Prakash
Background: In this study, we used a convolutional neural network (CNN) to classify Alzheimer’s disease (AD), mild cognitive impairment (MCI), and normal control (NC) subjects based on images of the hippocampus region extracted from magnetic resonance (MR) images of the brain. Materials and Methods: The datasets used in this study were obtained from the Alzheimer's Disease Neuroimaging Initiative (ADNI). To segment the hippocampal region automatically, the patient brain MR images were matched to the International Consortium for Brain Mapping template (ICBM) using 3D-Slicer software. Using prior knowledge and anatomical annotation label information, the hippocampal region was automatically extracted from the brain MR images. Results: The area of the hippocampus in each image was preprocessed using local entropy minimization with a bi-cubic spline model (LEMS) by an inhomogeneity intensity correction method. To train the CNN model, we separated the dataset into three groups, namely AD/NC, AD/MCI, and MCI/NC. The prediction model achieved an accuracy of 92.3% for AD/NC, 85.6% for AD/MCI, and 78.1% for MCI/NC. Conclusion: The results of this study were compared to those of previous studies, and summarized and analyzed to facilitate more flexible analyses based on additional experiments. The classification accuracy obtained by the proposed method is highly accurate. These findings suggest that this approach is efficient and may be a promising strategy to obtain good AD, MCI and NC classification performance using small patch images of hippocampus instead of whole slide images.

21 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
HMHADI SEDIGH MALEKROODI
HADI SEDIGH MALEKROODI
NVNuwan Madusanka Vithanage
Nuwan Madusanka Vithanage
BLByeong-il Lee
Byeong-il Lee
MYMyunggi Yi
Myunggi Yi
Speech impairments often emerge as one of the primary indicators of Parkinson’s disease (PD), albeit not readily apparent in its early stages. While previous studies focused predominantly on binary PD detection, this research explored the use of deep learning models to automatically classify sustained vowel recordings into healthy controls, mild PD, or severe PD based on motor symptom severity scores. Popular convolutional neural network (CNN) architectures, VGG and ResNet, as well as vision transformers, Swin, were fine-tuned on log mel spectrogram image representations of the segmented voice data. Furthermore, the research investigated the effects of audio segment lengths and specific vowel sounds on the performance of these models. The findings indicated that implementing longer segments yielded better performance. The models showed strong capability in distinguishing PD from healthy subjects, achieving over 95% precision. However, reliably discriminating between mild and severe PD cases remained challenging. The VGG16 achieved the best overall classification performance with 91.8% accuracy and the largest area under the ROC curve. Furthermore, focusing analysis on the vowel /u/ could further improve accuracy to 96%. Applying visualization techniques like Grad-CAM also highlighted how CNN models focused on localized spectrogram regions while transformers attended to more widespread patterns. Overall, this work showed the potential of deep learning for non-invasive screening and monitoring of PD progression from voice recordings, but larger multi-class labeled datasets are needed to further improve severity classification.

4 December 2019 in Cancers
Verified
Journal Article
Open access
PDF file
Subrata BhattacharjeeSubrata Bhattacharjee
Subrata Bhattacharjee
CKCho-Hee Kim
Cho-Hee Kim
HPHyeon-Gyun Park
Hyeon-Gyun Park
DPDeekshitha Prakash
Deekshitha Prakash
NVNuwan Madusanka Vithanage
Nuwan Madusanka Vithanage
HCHeung-Kook Choi
Heung-Kook Choi
Microscopic biopsy images are coloured in nature because pathologists use the haematoxylin and eosin chemical colour dyes for biopsy examinations. In this study, biopsy images are used for histological grading and the analysis of benign and malignant prostate tissues. The following PCa grades are analysed in the present study: benign, grade 3, grade 4, and grade 5. Biopsy imaging has become increasingly important for the clinical assessment of PCa. In order to analyse and classify the histological grades of prostate carcinomas, pixel-based colour moment descriptor (PCMD) and gray-level co-occurrence matrix (GLCM) methods were used to extract the most significant features for multilayer perceptron (MLP) neural network classification. Haar wavelet transformation was carried out to extract GLCM texture features, and colour features were extracted from RGB (red/green/blue) colour images of prostate tissues. The MANOVA statistical test was performed to select significant features based on F-values and P-values using the R programming language. We obtained an average highest accuracy of 92.7% using level-1 wavelet texture and colour features. The MLP classifier performed well, and our study shows promising results based on multi-feature classification of histological sections of prostate carcinomas.

24 July 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Subrata BhattacharjeeSubrata Bhattacharjee
Subrata Bhattacharjee
HPHyeon-Gyun Park
Hyeon-Gyun Park
CKCho-Hee Kim
Cho-Hee Kim
DPDeekshitha Prakash
Deekshitha Prakash
NVNuwan Madusanka Vithanage
Nuwan Madusanka Vithanage
HCHeung-Kook Choi
Heung-Kook Choi
An adenocarcinoma is a type of malignant cancerous tissue that forms from a glandular structure in epithelial tissue. Analyzed stained microscopic biopsy images were used to perform image manipulation and extract significant features for support vector machine (SVM) classification, to predict the Gleason grading of prostate cancer (PCa) based on the morphological features of the cell nucleus and lumen. Histopathology biopsy tissue images were used and categorized into four Gleason grade groups, namely Grade 3, Grade 4, Grade 5, and benign. The first three grades are considered malignant. K-means and watershed algorithms were used for color-based segmentation and separation of overlapping cell nuclei, respectively. In total, 400 images, divided equally among the four groups, were collected for SVM classification. To classify the proposed morphological features, SVM classification based on binary learning was performed using linear and Gaussian classifiers. The prediction model yielded an accuracy of 88.7% for malignant vs. benign, 85.0% for Grade 3 vs. Grade 4, 5, and 92.5% for Grade 4 vs. Grade 5. The SVM, based on biopsy-derived image features, consistently and accurately classified the Gleason grading of prostate cancer. All results are comparatively better than those reported in the literature.

17 August 2023 in Cancers
Verified
Journal Article
Open access
PDF file
NVNuwan Madusanka Vithanage
Nuwan Madusanka Vithanage
PJPramudini Jayalath
Pramudini Jayalath
DFDileepa Fernando
Dileepa Fernando
LYLasith Yasakethu
Lasith Yasakethu
BLByeong-il Lee
Byeong-il Lee
Accurate classification of cancer images plays a crucial role in diagnosis and treatment planning. Deep learning (DL) models have shown promise in achieving high accuracy, but their performance can be influenced by variations in Hematoxylin and Eosin (H&E) staining techniques. In this study, we investigate the impact of H&E stain normalization on the performance of DL models in cancer image classification. We evaluate the performance of VGG19, VGG16, ResNet50, MobileNet, Xception, and InceptionV3 on a dataset of H&E-stained cancer images. Our findings reveal that while VGG16 exhibits strong performance, VGG19 and ResNet50 demonstrate limitations in this context. Notably, stain normalization techniques significantly improve the performance of less complex models such as MobileNet and Xception. These models emerge as competitive alternatives with lower computational complexity and resource requirements and high computational efficiency. The results highlight the importance of optimizing less complex models through stain normalization to achieve accurate and reliable cancer image classification. This research holds tremendous potential for advancing the development of computationally efficient cancer classification systems, ultimately benefiting cancer diagnosis and treatment.