Software for Tomographic Image Reconstruction (STIR) is an open-source library for PET and SPECT image reconstruction, implementing iterative reconstruction as well as 2D- and 3D-filtered back projection. Quantitative reconstruction of PET data requires the knowledge of the scanner geometry. Typical scanners, clinical as well as pre-clinical ones, use a block-type geometry. Several rectangular blocks of crystals are arranged into regular polygons. Multiple of such polygons are arranged along the scanner axis. However, the geometrical representation of a scanner provided by STIR is a cylinder made of rings of individual crystals equally distributed in axial and transaxial directions. The data of realistic scanners are projected onto such virtual scanners prior to image reconstruction. This results in reduced quality of the reconstructed image. In this study, we implemented the above-described block geometry into the STIR library, permitting the image reconstruction without the interpolation step. In order to evaluate the difference in image quality, we performed Monte Carlo simulation studies of three different scanner designs: two scanners with multiple crystals per block and one with a single crystal per block. Simulated data were reconstructed using the standard STIR method and the newly implemented block geometry. Visual comparison between the images reconstructed by the two models for the block-type scanners shows that the new implementation enhances the image quality to the extent that the results before normalization correction are comparable with those after normalization correction. The simulation result of a uniform cylinder shows that the coefficient of variation decreases from 25.8% to 20.9% by using the new implementation in STIR. Spatial resolution is enhanced resulting in a lower partial loss of intensity in sources of small size, e.g., the spill-over ratio for spherical sources of 1.8 mm diameter is 0.19 in the block and 0.34 in the cylindrical model. Results indicate a significant improvement for the new model in comparison with the old one which mapped the polygonal geometry into a cylinder. The new implementation was tested and is available for use via the library of Swiss Federal Institute of Technology in Zurich (ETH).
24 January 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
The small animal fast insert for mRi (SAFIR) positron emission tomography insert was proposed for quantitative dynamic acquisition inside a preclinical 7T magnetic resonance imaging scanner to study kinetics of short-lived tracers. For this purpose, the SAFIR readout should be capable of handling high count rates and achieving excellent timing performance. We evaluated one of the available application specific integrated circuits (ASICs) for SiPM readout, namely SiPM timing chip (STiC) version 3.1. In this paper, we show the performances of the SAFIR PET detector with the STiC ASIC readout. The SAFIR PET detector consists of an 8 x 8 array of lutetium yttrium oxyorthosilicate 2.1 mm x 2.1 mm x 12 mm crystals coupled, with optical grease, to an 8 x 8 array of SiPMs with a 2.0 mm x 2.0 mm photo-sensitive area. Signals from the individual SiPM channels were digitized by the STiC ASIC. Hit's arrival time and time-over-threshold (TOT) were recorded into time stamps with 50.2-ps least significant bit. We obtained an average energy resolution of 18.5% full width at half maximum (FWHM) at 511-keV photopeak after TOT nonlinearity correction and an average coincidence resolving time resolution of 244-ps FWHM with time walk correction that satisfy our requirements specification on the detector performance.
18 March 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
The SAFIR collaboration is currently developing a high-rate positron emission tomography (PET) insert to study fast kinetic processes in small animals. Our insert is designed for simultaneous image acquisition with a preclinical 7T magnetic resonance (MR) imaging device. In contrast to existing preclinical PET scanners and inserts, our hardware is optimized for high-rate measurements with source activities up to 500MBq. As a first step, the SAFIR Prototype insert was constructed. This already incorporates the final components, but has a reduced axial field-of-view (35.6 mm). We use lutetium-yttrium oxyorthosilicate crystals (2.12 × 2.12 × 13 mm3) one-to-one coupled to silicon photomultipliers. All analogue signals are digitized within the insert. We use 49 MR-compatible DC-DC converters in the insert to provide the power to all readout electronics. After shimming, no degradation of the homogeneity of the static B0 field in the MR scanner was observed. During full operation we saw a minor reduction in the signal-to-noise ratio of theMRdata of 4.9%. With a low activity point source (22Na 0.65MBq) we obtained a coincidence energy resolution of 13.8% (FWHM) and a coincidence timing resolution of 194 ps (FWHM). First PET/MR rat brain and high-rate mouse cardiac images (84.9MBq) are shown in this work.
1 February 2017 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
The proposed SAFIR PET detector will measure positron electron annihilations at injected activities up to 500 MBq in a mouse or rat. The system is required to have the best possible timing resolution in order to remove accidental coincidences (randoms) and maximise the image quality for short time frames allowing the possibility of 4-D kinetic modelling of simultaneous PET and MRI for the first time. Two different ASICs, TOFPET and STiC, have been investigated with LYSO crystal scintillators coupled to SiPM detectors and using 18F sources up to 480 MBq. Timing responses are very encouraging with a coincidence time resolution of ~100 ps measured at low activities, degrading to 130 ps at the foreseen scanner maximum event rate. Sensitivities for single event rates and coincidences are measured and compared with Geant4 Monte Carlo simulations.
NeuroLF is a dedicated brain PET system with an octagonal prism shape housed in a scanner head that can be positioned around a patient’s head. Because it does not have MR or CT capabilities, attenuation correction based on an estimation of the attenuation map is a crucial feature. In this article, we demonstrate this method on [18F]FDG PET brain scans performed with a low-resolution proof of concept prototype of NeuroLF called BPET. We perform an affine registration of a template PET scan to the uncorrected emission image, and then apply the resulting transform to the corresponding template attenuation map. Using a whole-body PET/CT system as reference, we quantitively show that this method yields comparable image quality (0.893 average correlation to reference scan) to using the reference µ-map as obtained from the CT scan of the imaged patient (0.908 average correlation). We conclude from this initial study that attenuation correction using template registration instead of a patient CT delivers similar results and is an option for patients undergoing brain PET.