Ekaterina Mikhaylova

Dr. Ekaterina Mikhaylova


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MJMarkus Jehl
Markus Jehl
EMEkaterina Mikhaylova
Ekaterina Mikhaylova
VTValerie Treyer
Valerie Treyer
MHMarlena Hofbauer
Marlena Hofbauer
MHMartin W Huellner
Martin W Huellner
JFJannis Fischer
Jannis Fischer
NeuroLF is a dedicated brain PET system with an octagonal prism shape housed in a scanner head that can be positioned around a patient’s head. Because it does not have MR or CT capabilities, attenuation correction based on an estimation of the attenuation map is a crucial feature. In this article, we demonstrate this method on [18F]FDG PET brain scans performed with a low-resolution proof of concept prototype of NeuroLF called BPET. We perform an affine registration of a template PET scan to the uncorrected emission image, and then apply the resulting transform to the corresponding template attenuation map. Using a whole-body PET/CT system as reference, we quantitively show that this method yields comparable image quality (0.893 average correlation to reference scan) to using the reference µ-map as obtained from the CT scan of the imaged patient (0.908 average correlation). We conclude from this initial study that attenuation correction using template registration instead of a patient CT delivers similar results and is an option for patients undergoing brain PET.

18 June 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
VDViet Dao
Viet Dao
EMEkaterina Mikhaylova
Ekaterina Mikhaylova
MAMax Ludwig Ahnen
Max Ludwig Ahnen
JFJannis Fischer
Jannis Fischer
KTKris Thielemans
Kris Thielemans
CTCharalampos Tsoumpas
Charalampos Tsoumpas
Software for Tomographic Image Reconstruction (STIR) is an open source C++ library used to reconstruct single photon emission tomography and positron emission tomography (PET) data. STIR has an experimental scanner geometry modelling feature to accurately model detector placement. In this study, we test and improve this new feature using several types of data: Monte Carlo simulations and measured phantom data acquired from a dedicated brain PET prototype scanner. The results show that the new geometry class applied to non-cylindrical PET scanners improved spatial resolution, uniformity, and image contrast. These are directly observed in the reconstructions of small features in the test quality phantom. Overall, we conclude that the revised “BlocksOnCylindrical” class will be a valuable addition to the next STIR software release with adjustments of existing features (Single Scatter Simulation, forward projection, attenuation corrections) to “BlocksOnCylindrical”.

28 August 2025 in Research Square
Verified
Preprint
Open access
PDF file
EMEkaterina Mikhaylova
Ekaterina Mikhaylova
MAMax Ludwig Ahnen
Max Ludwig Ahnen
HBHenryk Barthel
Henryk Barthel
JDJan Debus
Jan Debus
JFJannis Fischer
Jannis Fischer
ISIlaria Sacco
Ilaria Sacco
Background: This work presents the NEMA NU2 2018 performance evaluation of the NeuroLF Basic, a compact and fully integrated brain positron emission tomography (PET) system based on 10-mm-long LYSO crystals. The evaluation includes measurements and simulations of spatial resolution, scatter fraction, noise equivalent count rate (NECR), accuracy of corrections, image quality, and sensitivity, following standardized protocols to ensure reliable and reproducible results. Results: The average filtered-back-projection spatial resolution, measured at 1 cm and 10 cm radial offsets, was found to be 2.56 mm and 3.82 mm, respectively, highlighting the system’s ability to capture details essential for neuroimaging applications. The scatter fraction was determined to be 24.2% at the peak NECR, reflecting the system’s capability to minimize unwanted scattered events. The peak NECR was measured at 55.3 kcps at an activity concentration of 8.1 kBq/mL, demonstrating the system’s efficiency in handling typical neuroimaging count rates with optimal signal-to-noise characteristics. NeuroLF shows excellent accuracy of corrections at 3.7% and good image contrast for hot vials in a warm background in the adapted image quality procedure with the ACR Esser phantom, achieving values of 87.5%, 77%, 60%, and 35.8% for 25-, 16-, 12-, and 8-mm-diameter vials, respectively, with a maximum background variability of 10% for the 8-mm-diameter vial. Sensitivity, evaluated using a 70-cm-long line source, was measured at 5.85 cps/kBq at the center of the field of view and 8.08 cps/kBq at a 10 cm radial offset, confirming the system’s good capability to detect 511 keV gamma photons. The measured NEMA NU2 2018 results show good agreement with Monte Carlo simulation results, validating the accuracy of the simulated NeuroLF model for future research and system optimization. Conclusions: These results demonstrate the NeuroLF’s potential to deliver high-quality images, good detection efficiency, and robust quantitative performance, making it a valuable tool for clinical applications in neuroimaging. The comprehensive NEMA NU2 2018 evaluation demonstrates NeuroLF’s performance.