ABDELKADER BENKHETTOU

Dr. ABDELKADER BENKHETTOU


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2026 in Journal of Biomimetics, Biomaterials and Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
IBIsmail Boudjemaa
Ismail Boudjemaa
OKOmar Khatir
Omar Khatir
ABABDELKADER BENKHETTOU
ABDELKADER BENKHETTOU
SASAHLI Abderahmane
SAHLI Abderahmane
BBBel Abbes Bachir Bouiadjra
Bel Abbes Bachir Bouiadjra
SBSmail Benberk
Smail Benberk
The thickness of the residual limb’s soft tissue plays a crucial role in determining the mechanical behavior and stress distribution at the stump–prosthesis interface. Using finite element analysis (FEA), this study investigates the biomechanical effects of different soft tissue thicknesses (30 mm, 50 mm, and 70 mm) on stress distribution. A patient-specific finite element model of the residual limb was developed to simulate realistic anatomical and mechanical conditions. To replicate physiological loading, a static vertical load of 350 N was applied, and the interface between the residual limb and the prosthetic liner was modeled using appropriate contact mechanics. The results revealed that reducing the soft tissue thickness to 3 cm produced higher Von Mises stress concentrations (0.115 MPa) and contact pressure (0.0697 MPa), which may increase discomfort and the risk of tissue damage. Conversely, increasing the thickness to 70 mm reduced stress values (0.016 MPa) and contact pressure (0.0312 MPa) but led to excessive deformations (6.277 mm) that could compromise prosthetic stability. An optimal soft tissue thickness of 5 cm was identified, where Von Mises stress and contact pressure remained at moderate levels, offering a balance between stress distribution and mechanical stability. These findings provide valuable guidance for optimizing prosthetic socket design, as maintaining appropriate soft tissue thickness can enhance comfort, reduce pressure-related injuries, and improve the overall functionality of lower-limb prostheses.

6 October 2026 in Polymers
Verified
Journal Article
Open access
PDF file
IBIsmail Boudjemaa
Ismail Boudjemaa
OKOmar Khatir
Omar Khatir
ABABDELKADER BENKHETTOU
ABDELKADER BENKHETTOU
BBBel Abbes Bachir Bouiadjra
Bel Abbes Bachir Bouiadjra
SASAHLI Abderahmane
SAHLI Abderahmane
MKMuhammet KALKISIM
Muhammet KALKISIM
This study investigates the influence of printing angle on the mechanical performance of 3D-printed prosthetic sockets through an integrated experimental and computational approach. Tensile tests were conducted on Acrylonitrile Butadiene Styrene (ABS), Polylactic Acid (PLA), and enhanced PLA (PLA+) specimens fabricated at four orientations (0°, 30°, 60°, and 90°). The results confirmed clear printing orientation dependence, with Young’s modulus and ultimate tensile strength varying across printing angles in a material-specific manner. The experimentally determined Young’s modulus for each material–orientation combination was implemented as an equivalent isotropic elastic input in a separate finite element simulation of a patient-specific transtibial socket under simplified quasi-static stance loading. The FE simulations revealed that PLA+ printed at 0° provided a balanced structural response: it maintained von Mises stress within the socket at 1.98 MPa, limited displacement to 0.29 mm, and kept interface contact pressure at 0.089 MPa. In contrast, the more compliant ABS, particularly at a 90° orientation, exhibited a higher displacement of approximately 0.37 mm, which may influence socket compliance. This research provides quantitative, data-driven guidelines for the additive manufacturing of load-bearing medical devices, demonstrating that precise control of print orientation and material selection is essential for engineering prosthetic sockets that balance structural support with patient-specific interface requirements.