Ismail Boudjemaa

Dr. Ismail Boudjemaa

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2025 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
TMTaieb Messaad
Taieb Messaad
ABAbdelghani Baltach
Abdelghani Baltach
MZMohammed El Sallah Zagane
Mohammed El Sallah Zagane
IBIsmail Boudjemaa
Ismail Boudjemaa
MMMokhtar Messaad
Mokhtar Messaad

3 February 2026 in Journal of Biomimetics, Biomaterials and Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
IBIsmail Boudjemaa
Ismail Boudjemaa
OKOmar Khatir
Omar Khatir
ABABDELKADER BENKHETTOU
ABDELKADER BENKHETTOU
SASAHLI Abderahmane
SAHLI Abderahmane
BBBel Abbes Bachir Bouiadjra
Bel Abbes Bachir Bouiadjra
SBSmail Benberk
Smail Benberk
The thickness of the residual limb’s soft tissue plays a crucial role in determining the mechanical behavior and stress distribution at the stump–prosthesis interface. Using finite element analysis (FEA), this study investigates the biomechanical effects of different soft tissue thicknesses (30 mm, 50 mm, and 70 mm) on stress distribution. A patient-specific finite element model of the residual limb was developed to simulate realistic anatomical and mechanical conditions. To replicate physiological loading, a static vertical load of 350 N was applied, and the interface between the residual limb and the prosthetic liner was modeled using appropriate contact mechanics. The results revealed that reducing the soft tissue thickness to 3 cm produced higher Von Mises stress concentrations (0.115 MPa) and contact pressure (0.0697 MPa), which may increase discomfort and the risk of tissue damage. Conversely, increasing the thickness to 70 mm reduced stress values (0.016 MPa) and contact pressure (0.0312 MPa) but led to excessive deformations (6.277 mm) that could compromise prosthetic stability. An optimal soft tissue thickness of 5 cm was identified, where Von Mises stress and contact pressure remained at moderate levels, offering a balance between stress distribution and mechanical stability. These findings provide valuable guidance for optimizing prosthetic socket design, as maintaining appropriate soft tissue thickness can enhance comfort, reduce pressure-related injuries, and improve the overall functionality of lower-limb prostheses.

13 August 2026 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
MBMohamed Babakhali
Mohamed Babakhali
LALaid Aminallah
Laid Aminallah
AMAli Merdji
Ali Merdji
IBIsmail Boudjemaa
Ismail Boudjemaa
HAHashem Alkhaldi
Hashem Alkhaldi
SRSandipan Roy
Sandipan Roy
The durability of implant-supported dental restorations depends heavily on the layer of cement that bonds the prosthetic crown to the framework. However, the influence of cement thickness on the distribution of mechanical stresses within the implant-prosthesis system remains poorly understood. The aim of this study is to evaluate the effect of cement layer thickness on the biomechanical behavior of a metal-ceramic implant-supported restoration. A three-dimensional finite element model of a mandibular segment, incorporating cortical and cancellous bone, a titanium implant and abutment, and a metal-ceramic crown, was developed using SolidWorks software. Three thicknesses of cement were considered: 20, 40, and 60 µm. Static loads were applied to the crown in three directions: axial (100 N), buccal-lingual (50 N), and mesio-distal (23.4 N). The equivalent Von Mises stresses were evaluated at the level of the peri-implant bone, the cement layer, the crown, and the implant-abutment-frame interfaces in order to analyze the influence of cement thickness on stress distribution. The increase in cement thickness led to a decrease in maximum stresses in the peri-implant bone, from 12.32 MPa (20 µm) to 10.49 MPa (60 µm) in cortical bone, and from 2.51 to 1.88 MPa in cancellous bone, as well as a reduction in stresses in the cement layer from 9.74 to 8.47 MPa under axial load. In contrast, stresses in the crown increased with cement thickness, reaching 65.24 MPa for 60 µm. No significant variation in stresses was observed at the implant-abutment-frame interface. The thickness of the cement layer significantly influences the distribution of stresses in implant-supported restorations. A greater thickness protects the peri-implant bone by dissipating loads, but increases the stresses in the crown. Optimizing the thickness of the cement is therefore a key parameter for improving the clinical longevity of implant restorations.

6 October 2026 in Polymers
Verified
Journal Article
Open access
PDF file
IBIsmail Boudjemaa
Ismail Boudjemaa
OKOmar Khatir
Omar Khatir
ABABDELKADER BENKHETTOU
ABDELKADER BENKHETTOU
BBBel Abbes Bachir Bouiadjra
Bel Abbes Bachir Bouiadjra
SASAHLI Abderahmane
SAHLI Abderahmane
MKMuhammet KALKISIM
Muhammet KALKISIM
This study investigates the influence of printing angle on the mechanical performance of 3D-printed prosthetic sockets through an integrated experimental and computational approach. Tensile tests were conducted on Acrylonitrile Butadiene Styrene (ABS), Polylactic Acid (PLA), and enhanced PLA (PLA+) specimens fabricated at four orientations (0°, 30°, 60°, and 90°). The results confirmed clear printing orientation dependence, with Young’s modulus and ultimate tensile strength varying across printing angles in a material-specific manner. The experimentally determined Young’s modulus for each material–orientation combination was implemented as an equivalent isotropic elastic input in a separate finite element simulation of a patient-specific transtibial socket under simplified quasi-static stance loading. The FE simulations revealed that PLA+ printed at 0° provided a balanced structural response: it maintained von Mises stress within the socket at 1.98 MPa, limited displacement to 0.29 mm, and kept interface contact pressure at 0.089 MPa. In contrast, the more compliant ABS, particularly at a 90° orientation, exhibited a higher displacement of approximately 0.37 mm, which may influence socket compliance. This research provides quantitative, data-driven guidelines for the additive manufacturing of load-bearing medical devices, demonstrating that precise control of print orientation and material selection is essential for engineering prosthetic sockets that balance structural support with patient-specific interface requirements.

27 October 2026 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
IBIsmail Boudjemaa
Ismail Boudjemaa
ABAbdelkader Benkhettou
Abdelkader Benkhettou
OKOmar Khatir
Omar Khatir
MYMURAT YAYLACI
MURAT YAYLACI
YAYamina Abdoune
Yamina Abdoune
RBRedouane Benzeguir
Redouane Benzeguir
This finite element study investigates the biomechanical design of a multi-layer orthopedic mattress, with particular focus on optimizing a specialized egg-crate foam top layer integrated within a tri-layer support system. While minimizing stress concentrations caused by surface protrusions was one key objective, the broader research aim was to develop a comprehensive mattress architecture where each layer – including a transition mid-layer and supportive base – serves distinct mechanical functions. The topographical surface geometry was carefully coupled with tuned hyperelastic properties to achieve dual objectives: reducing interface pressure peaks while maintaining system-level structural integrity and load distribution. Computational results demonstrate that the proposed multi-layer design demonstrates improved mechanical performance. The compliant egg-crate configuration reduced maximum principal logarithmic strain by 58%–62% and peak contact pressure to 0.024 MPa, while maintaining adequate support through optimized stress transfer to underlying layers. Importantly, the study identifies critical design thresholds beyond which surface texturing becomes counterproductive, providing valuable insights for therapeutic mattress engineering. This work establishes an integrated approach to patient support surface design, advancing beyond conventional single-layer optimization to address the complex biomechanical interactions in multi-layer mattress systems for pressure ulcer prevention.