Lasse Johannes Strudthoff

Mr. Lasse Johannes Strudthoff

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2024 in Analytica Chimica Acta
Verified
Journal Article
Open access
MHMarie-T. Hopp
Marie-T. Hopp
SVSonali M. Vaidya
Sonali M. Vaidya
KGKarina M. Grimmig
Karina M. Grimmig
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
JCJohanna C. Clauser
Johanna C. Clauser
Diana ImhofDiana Imhof
Diana Imhof
Intravascular hemolysis is associated with massive release of hemoglobin and consequently labile heme into the blood, resulting in prothrombotic and proinflammatory events in patients. Though heme is well-known to participate in these adverse effects, it is not monitored. Instead, haptoglobin and hemoglobin serve as clinical biomarkers. The quantification of labile heme together with hemoglobin, however, should be considered in clinical diagnosis as well, to obtain a complete picture of the hemolytic state in patients. So far, quantification techniques for labile heme were not yet systematically analyzed and compared for their clinical application potential, especially in the presence of hemoglobin. Two commercial assays (Heme Assay Kit®, Hemin Assay Kit®) and five common approaches (pyridine hemochromogen assay, apo-horseradish peroxidase-based assay, UV/Vis spectroscopy, HPLC, mass spectrometry) were analyzed concerning their linearity, accuracy, and precision, as well as their ability to distinguish between hemoglobin-bound heme and labile heme. Further, techniques for the quantification of hemoglobin (Harboe method, SLS method, Hemastix®) were included to study their selectivity for hemoglobin and potential interference by the presence of labile heme. Both, indirect and direct approaches were suitable for the determination of a wide concentration of heme (∼0.02-45 μM) and hemoglobin (∼0.002-17 μM). A clear distinction between hemoglobin-bound heme and labile heme with one method was not possible. Thus, a novel combined approach is presented and applied to human and porcine plasma samples for the determination of hemoglobin and labile heme. Our results demonstrate the need to develop improved techniques to differentiate labile and protein-bound heme for early detection of intravascular hemolysis. Here, we present a novel strategy by combining two spectroscopic methods, which is most reliable as an easy-to-use tool for the determination of hemoglobin and heme levels in plasma samples for the diagnosis of intravascular hemolysis and in basic biomedical research.

31 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
JFJannis Mathias Focke
Jannis Mathias Focke
FHFelix Hesselmann
Felix Hesselmann
AKAndreas Kaesler
Andreas Kaesler
ACAna Martins Costa
Ana Martins Costa
SJSebastian Victor Jansen
Sebastian Victor Jansen
The overall survival rate of extracorporeal life support (ECLS) remains at 60%. Research and development has been slow, in part due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator (“RatOx”) and presents preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performances over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199. At the maximum possible amount of effective fiber surface area and a blood flow of 100 mL/min, the oxygenator performance was tested to a maximum of 6.27 mL O2/min and 8.2 mL CO2/min, respectively. The priming volume for the largest fiber module is 5.4 mL, while the smallest possible configuration with a single fiber mat layer has a priming volume of 1.1 mL. The novel RatOx ECLS system has been evaluated in vitro and has demonstrated a high degree of compliance with all pre-defined functional criteria for rodent-sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.

22 January 2022 in Membranes
Verified
Journal Article
Open access
PDF file
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
HLHannah Lüken
Hannah Lüken
SJSebastian Victor Jansen
Sebastian Victor Jansen
JPJan Petran
Jan Petran
PSPeter C. Schlanstein
Peter C. Schlanstein
RKRüdger Kopp
Rüdger Kopp
Extracorporeal membrane oxygenation (ECMO) is an established rescue therapy for patients with chronic respiratory failure waiting for lung transplantation (LTx). The therapy inherent immobilization may result in fatigue, consecutive deteriorated prognosis, and even lost eligibility for transplantation. We conducted a feasibility study on a novel system designed for the deployment of a portable ECMO device, enabling the physical exercise of awake patients prior to LTx. The system comprises a novel oxygenator with a directly connected blood pump, a double-lumen cannula, gas blender and supply, as well as control and energy management. In vitro experiments included tests regarding performance, efficiency, and blood damage. A reduced system was tested in vivo for feasibility using a novel large animal model. Six anesthetized pigs were first positioned in supine position, followed by a 45° angle, simulating an upright position of the patients. We monitored performance and vital parameters. All in vitro experiments showed good performance for the respective subsystems and the integrated system. The acute in vivo trials of 8 h duration confirmed the results. The novel portable ECMO-system enables adequate oxygenation and decarboxylation sufficient for, e.g., the physical exercise of designated LTx-recipients. These results are promising and suggest further preclinical studies on safety and efficacy to facilitate translation into clinical application.

18 October 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
JKJan Korte
Jan Korte
Tobias LauwigiTobias Lauwigi
Tobias Lauwigi
LHLisa Herzog
Lisa Herzog
ATAlexander Theißen
Alexander Theißen
KSKai Suchorski
Kai Suchorski
PWPatrick Winnersbach
Patrick Winnersbach
Blood clot formation inside the membrane oxygenator (MO) remains a risk in extracorporeal membrane oxygenation (ECMO). It is associated with thromboembolic complications and normally detectable only at an advanced stage. Established clinical monitoring techniques lack predictive capabilities, emphasizing the need for refinement in MO monitoring towards an early warning system. In this study, an MO was modified by integrating four sensor fibers in the middle of the hollow fiber mat bundle, allowing for bioimpedance measurement within the MO. The modified MO was perfused with human blood in an in vitro test circuit until fulminant clot formation. The optical analysis of clot residues on the extracted hollow fibers showed a clot deposition area of 51.88% ± 14.25%. This was detectable via an increased bioimpedance signal with a significant increase 5 min in advance to fulminant clot formation inside the MO, which was monitored by the clinical gold standard (pressure difference across the MO (dp-MO)). This study demonstrates the feasibility of detecting clot growth early and effectively by measuring bioimpedance within an MO using integrated sensor fibers. Thus, bioimpedance may even outperform the clinical gold standard of dp-MO as a monitoring method by providing earlier clot detection.

27 February 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
JFJannis Mathias Focke
Jannis Mathias Focke
FHFelix Hesselmann
Felix Hesselmann
AKAndreas Kaesler
Andreas Kaesler
ACAna Martins Costa
Ana Martins Costa
SJSebastian Victor Jansen
Sebastian Victor Jansen
The survival rate of extracorporeal life support (ECLS) remains overall at 60 %. Research and development is slow, partly due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator (“RatOx”) and shows preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performance over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199.At the maximum possible amount of effective fiber surface and a blood flow of 100 ml/min, the oxygenator performance has been tested to a maximum of 6.27 ml O2/min and 8.2 ml CO2/min, respectively. The priming volume for this the largest fiber module is 5.4 ml, while the smallest possible configuration with a single fiber mat layer has 1.1 ml of priming volume. The novel RatOx ECLS system has been evaluated in-vitro to comply to a high degree with all predefined functionality criteria for rodent sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.

15 November 2023 in Animals
Verified
Journal Article
Open access
PDF file
MDMatthias Manfred Deininger
Matthias Manfred Deininger
CBCarl-Friedrich Benner
Carl-Friedrich Benner
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
CBChristian Simon Bruells
Christian Simon Bruells
TBThomas Breuer
Thomas Breuer
The development of biomedical soft- or hardware frequently includes testing in animals. However, large efforts have been made to reduce the number of animal experiments, according to the 3Rs principle. Simultaneously, a significant number of surplus animals are euthanized without scientific necessity. The primary aim of this study was to establish a post-mortem rat perfusion model using extracorporeal membrane oxygenation (ECMO) in surplus rat cadavers and generate first post vivo results concerning the oxygenation performance of a recently developed ECMO membrane oxygenator. Four rats were euthanized and connected post-mortem to a venous–arterial ECMO circulation for up to eight hours. Angiographic perfusion proofs, blood gas analyses and blood oxygenation calculations were performed. The mean preparation time for the ECMO system was 791 ± 29 s and sufficient organ perfusion could be maintained for 463 ± 26 min, proofed via angiographic imaging and a mean femoral arterial pressure of 43 ± 17 mmHg. A stable partial oxygen pressure, a 73% rise in arterial oxygen concentration and an exponentially increasing oxygen extraction ratio up to 4.75 times were shown. Considering the 3Rs, the established post-mortal ECMO perfusion rat model using surplus animals represents a promising alternative to models using live animals. Given the preserved organ perfusion, its use could be conceivable for various biomedical device testing.