21 June 2021 in Bio-Design and Manufacturing
Verified
Journal Article
Open access
PDF file
FHFelix Hesselmann
Felix Hesselmann
JFJannis Mathias Focke
Jannis Mathias Focke
PSPeter C. Schlanstein
Peter C. Schlanstein
NSNiklas Steuer
Niklas Steuer
AKAndreas Kaesler
Andreas Kaesler
Jutta ArensJutta Arens
Jutta Arens
Currently, artificial-membrane lungs consist of thousands of hollow fiber membranes where blood flows around the fibers and gas flows inside the fibers, achieving diffusive gas exchange. At both ends of the fibers, the interspaces between the hollow fiber membranes and the plastic housing are filled with glue to separate the gas from the blood phase. During a uniaxial centrifugation process, the glue forms the “potting.” The shape of the cured potting is then determined by the centrifugation process, limiting design possibilities and leading to unfavorable stagnation zones associated with blood clotting. In this study, a new multiaxial centrifugation process was developed, expanding the possible shapes of the potting and allowing for completely new module designs with potentially superior blood flow guidance within the potting margins. Two-phase simulations of the process in conceptual artificial lungs were performed to explore the possibilities of a biaxial centrifugation process and determine suitable parameter sets. A corresponding biaxial centrifugation setup was built to prove feasibility and experimentally validate four conceptual designs, resulting in good agreement with the simulations. In summary, this study shows the feasibility of a multiaxial centrifugation process allowing greater variety in potting shapes, eliminating inefficient stagnation zones and more favorable blood flow conditions in artificial lungs. Graphic abstract

31 July 2024 in Journal of Membrane Science
Verified
Journal Article
Open access
JFJannis Mathias Focke
Jannis Mathias Focke
PBPaul-Luca Bonke
Paul-Luca Bonke
NGNicolas Gendron
Nicolas Gendron
TCTobias Call
Tobias Call
USUlrich Steinseifer
Ulrich Steinseifer
MNMichael Neidlin
Michael Neidlin

31 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
JFJannis Mathias Focke
Jannis Mathias Focke
FHFelix Hesselmann
Felix Hesselmann
AKAndreas Kaesler
Andreas Kaesler
ACAna Martins Costa
Ana Martins Costa
SJSebastian Victor Jansen
Sebastian Victor Jansen
The overall survival rate of extracorporeal life support (ECLS) remains at 60%. Research and development has been slow, in part due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator (“RatOx”) and presents preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performances over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199. At the maximum possible amount of effective fiber surface area and a blood flow of 100 mL/min, the oxygenator performance was tested to a maximum of 6.27 mL O2/min and 8.2 mL CO2/min, respectively. The priming volume for the largest fiber module is 5.4 mL, while the smallest possible configuration with a single fiber mat layer has a priming volume of 1.1 mL. The novel RatOx ECLS system has been evaluated in vitro and has demonstrated a high degree of compliance with all pre-defined functional criteria for rodent-sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.

18 October 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
JKJan Korte
Jan Korte
Tobias LauwigiTobias Lauwigi
Tobias Lauwigi
LHLisa Herzog
Lisa Herzog
ATAlexander Theißen
Alexander Theißen
KSKai Suchorski
Kai Suchorski
PWPatrick Winnersbach
Patrick Winnersbach
Blood clot formation inside the membrane oxygenator (MO) remains a risk in extracorporeal membrane oxygenation (ECMO). It is associated with thromboembolic complications and normally detectable only at an advanced stage. Established clinical monitoring techniques lack predictive capabilities, emphasizing the need for refinement in MO monitoring towards an early warning system. In this study, an MO was modified by integrating four sensor fibers in the middle of the hollow fiber mat bundle, allowing for bioimpedance measurement within the MO. The modified MO was perfused with human blood in an in vitro test circuit until fulminant clot formation. The optical analysis of clot residues on the extracted hollow fibers showed a clot deposition area of 51.88% ± 14.25%. This was detectable via an increased bioimpedance signal with a significant increase 5 min in advance to fulminant clot formation inside the MO, which was monitored by the clinical gold standard (pressure difference across the MO (dp-MO)). This study demonstrates the feasibility of detecting clot growth early and effectively by measuring bioimpedance within an MO using integrated sensor fibers. Thus, bioimpedance may even outperform the clinical gold standard of dp-MO as a monitoring method by providing earlier clot detection.

27 February 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
JFJannis Mathias Focke
Jannis Mathias Focke
FHFelix Hesselmann
Felix Hesselmann
AKAndreas Kaesler
Andreas Kaesler
ACAna Martins Costa
Ana Martins Costa
SJSebastian Victor Jansen
Sebastian Victor Jansen
The survival rate of extracorporeal life support (ECLS) remains overall at 60 %. Research and development is slow, partly due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator (“RatOx”) and shows preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performance over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199.At the maximum possible amount of effective fiber surface and a blood flow of 100 ml/min, the oxygenator performance has been tested to a maximum of 6.27 ml O2/min and 8.2 ml CO2/min, respectively. The priming volume for this the largest fiber module is 5.4 ml, while the smallest possible configuration with a single fiber mat layer has 1.1 ml of priming volume. The novel RatOx ECLS system has been evaluated in-vitro to comply to a high degree with all predefined functionality criteria for rodent sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.

11 January 2026 in Journal of Membrane Science
Verified
Journal Article
Open access
JFJannis Mathias Focke
Jannis Mathias Focke
KBKai P. Barbian
Kai P. Barbian
PBPaul-Luca Bonke
Paul-Luca Bonke
USUlrich Steinseifer
Ulrich Steinseifer
Jutta ArensJutta Arens
Jutta Arens
MNMichael Neidlin
Michael Neidlin