This article focuses on the investigation of the dynamic thermal barrier (TB) and dynamic thermal resistance (DTR) of the building envelope. The aim is to analyze the DTR as a function of the temperature change of the heat transfer medium supplied to the dynamic TB layer and to determine the energy potential of several materially different fragments of the building envelope. The functions of TB and DTR depend on the uniform and continuous maintenance of temperature in a given layer of the building structure. The methodology is based on the analysis and synthesis of thermal resistance calculation, wall heating, and computer simulation. The research results show that the relatively low mean temperature of the heat transfer medium of approximately θm = 17 °C delivered to the TB layer represents RDTR = up to 30 ((m2·K)/W) for an equivalent dynamic thermal insulation thickness of 1000 mm for a required standard resistance of RSTANDARD = 6.50 ((m2·K)/W) of the individual fragments analyzed with static thermal insulation of 65 to 210 mm. The energy potential of a thermal barrier (TB) represents an increase of approximately 500% in the thermal resistance and up to 1500% in the thickness of the dynamic thermal insulation. Further research on the dynamic thermal barrier and verification of the results of the parametric study will continue with comprehensive computer simulations and experimental measurements on the test cell.
Thermal engineering requirements for building structures are becoming more and more strict. Thermal barriers (TBs) are energy-active elements integrated into the building structure in which a heat transfer medium (water or air) flows. A survey of the scientific literature on the subject points to the fact that this is a very topical and promising area of research and, so far, most studies on TBs are based on calculations, computer simulations and experimental measurements. Few studies have focused on the economic and environmental aspects of TB use. Following the research results presented by authors from all over the world, as well as our contributions in this scientific field that are described in a European patent, three utility models and scientific articles, in this study we have focused on the evaluation of the TB in terms of energy performance, economic efficiency and environmental friendliness by comparing the use of a classical envelope wall with the required thickness of thermal insulation meeting the normative requirements for thermal resistance R ((m2K)/W) and a perimeter wall with an integrated TB significantly eliminating the thermal insulation thickness. We evaluate the use of the thermal barrier using: economic indicator one, where we compare the cost of heat delivered to the TB in a structure with significantly eliminated thermal insulation and the saved cost of thermal insulation at the standard thickness; economic indicator two, where we compare the cost of heat delivered to the TB in a structure with significantly eliminated thermal insulation with the potential gain from the sale of the useful area of the building gained compared to the area at the normative thickness of thermal insulation; and economic indicator three, where we compare the cost of heat delivered to the TB in a structure with significantly eliminated thermal insulation with the cost of grey energy at the normative thickness of thermal insulation. Based on a parametric study based on theoretical assumptions, it can be concluded that the thermal barrier shows a very promising and efficient solution in terms of the evaluation of economic indicators one to three, which are even more significant if we use heat for the TB from renewable energy sources (RES) or waste heat.
The research described in this study focuses on the innovation and optimization of building envelope panels with integrated energy-active elements in the thermal barrier function. It is closely related to developing and implementing the prototype prefabricated house IDA I with combined building-energy systems using renewable energy sources. We were inspired by the patented ®ISOMAX panel and system, which we have been researching and innovating for a long time. The thermal barrier has the function of eliminating heat loss/gain through the building envelope. By controlling the heat/cold transfer in the thermal barrier, it is possible to eliminate the thickness of the thermal insulation of the building envelope and thus achieve an equivalent thermal resistance of the building structure that is equal to the standard required value. The technical solution of the ISOMAX panel also brings, besides the use of the thermal barrier function, the function of heat/cold accumulation in the load-bearing part of the building envelope. Our research aimed to design and develop a panel for which the construction would be optimal in terms of thermal barrier operation and heat/cold accumulation. As the production panels in the lost formwork of expanded polystyrene (according to the patented system) proved to be too complicated and time consuming, and often showed shortcomings from a structural point of view, the next goal was to design a new, statically reliable panel construction with integrated energy-active elements and a time-saving, cost-effective, unified production directly in the panel factory. In order to develop and design an innovative panel with integrated energy-active elements, we analyzed the composition of the original panel and designed the composition of the innovative panel. We created mathematical–physical models of both panels and analyzed their energy potential. By induction and an analog form of formation, we designed the innovative panel. Based on the synthesis of the knowledge obtained from the scientific analysis and the transformation of this data, most of the building components and all the panels with integrated energy-active elements were manufactured directly in the prefabrication plant. Subsequently, the prototype of the prefabricated house IDA I was realized. The novelty of our innovative building envelope panel solution lies in the panel’s design, which has a heat loss/gain that is 2.6 times lower compared to the ISOMAX panel.
This study describes our experience in researching and designing an innovative way of operating combined building–energy systems using renewable energy sources. We used the concepts of the ISOMAX integrated building–energy system’s patented technical solution, which we have long been exploring and have developed various novel and original solutions, as inspiration for our research. A consistent peak heat/cooling supply is a key component of the patented ISOMAX system, which has also been proven in its use in many buildings. Energy systems are no longer dependent on unreliable, unpredictable, and hard-to-forecast geothermal and solar energy because of the peak energy source. We had to improve the original design to guarantee the efficient, comfortable, and dependable operation of all the energy systems in the building. We increased the capacity of the ventilation system by including a peak heat/cooling source, a short-term heat/cooling storage tank, and the option of using an air handling unit with heat recovery or a water/air heat exchanger. The addition of terminal elements for heating, cooling, and ventilation systems was also made, along with including a solar system, a wind turbine, and the potential for waste heat recovery. Our study led to the creation of a unique operating model that, with the building management system, optimizes all of the energy systems and heating/cooling sources. The utility model SK 5749 Y1 analyzes the various alternatives in great detail.
31 May 2019 in Periodica Polytechnica Mechanical Engineering
The aim of this study is to design industrial ventilation in the production hall. With respect to the many parameters which influence the appropriate proposal of industrial ventilation that need to be considered, there is a good chance for miscalculations when design the industrial ventilation. Especially when the heat loads from technology threaten the stability of construction of the building. There are two different ways of solution of aeration in the aluminium plant. There is only a natural ventilation using outside air in case of melting of aluminium and an adiabatic cooling for air inlet combined with natural ventilation. The results and practice has shown, that to use only an outside air is not sufficient and the temperature in the hall is really very high. Adiabatic cooling decreases the air inlet temperature in the production hall and improves the working conditions. A thermovision mapping of the technology was used prior to start the CFD modelling. The simulation emphasize the important effect of design and location of different elements on the functionality of ventilation proposal.
Research Area: Building components with integrated energy-active elements (BCEAE) are generally referred to as combined building-energy systems (CBES). Aim: Research on the application of energy (solar) roofs (ESR), ground heat storage (GHS), active thermal protection (ATP), and their cooperation in different modes of operation of energy systems with an emphasis on the use of renewable energy sources (RES) and waste heat. Methodology: The analysis and synthesis of the state of the art in the field, the inductive and analogical form of the creation of an innovative method of operation of combined building-energy systems, the development of an innovative solution of the envelope panel with integrated energy-active elements, the synthesis of the knowledge obtained from the scientific analysis and the transformation of the data into the design and implementation of the prototype of the prefabricated house IDA I and the experimental house EB2020. Results: The theoretical analysis of building structures with active thermal protection results in the determination of their energy potential and functionality, e.g., thermal barrier, heating/cooling, heat storage, etc. New technical solutions for envelopes with controlled heat transfer were proposed based on the implementation of experimental buildings. Conclusions: The novelty of our research lies in the design of different variants of the way of operation of energy systems using RES and in upgrading building envelope panels with integrated energy-active elements.