Pre-service teacher training offers various opportunities for trainees to become aware of and understand the qualities of good teaching. Towards the end of their training they should be able to identify clearly the criteria for measuring their readiness for teaching profession as well as identify their own strong and weak areas
This article focuses on the investigation of the dynamic thermal barrier (TB) and dynamic thermal resistance (DTR) of the building envelope. The aim is to analyze the DTR as a function of the temperature change of the heat transfer medium supplied to the dynamic TB layer and to determine the energy potential of several materially different fragments of the building envelope. The functions of TB and DTR depend on the uniform and continuous maintenance of temperature in a given layer of the building structure. The methodology is based on the analysis and synthesis of thermal resistance calculation, wall heating, and computer simulation. The research results show that the relatively low mean temperature of the heat transfer medium of approximately θm = 17 °C delivered to the TB layer represents RDTR = up to 30 ((m2·K)/W) for an equivalent dynamic thermal insulation thickness of 1000 mm for a required standard resistance of RSTANDARD = 6.50 ((m2·K)/W) of the individual fragments analyzed with static thermal insulation of 65 to 210 mm. The energy potential of a thermal barrier (TB) represents an increase of approximately 500% in the thermal resistance and up to 1500% in the thickness of the dynamic thermal insulation. Further research on the dynamic thermal barrier and verification of the results of the parametric study will continue with comprehensive computer simulations and experimental measurements on the test cell.
The integration of energy-active elements into the building envelope in the form of large-area heating/cooling, active thermal protection (ATP), thermal barriers (TB), and TABS represents a technical solution that is consistent with the principles of energy sustainability, resilience, and adaptability to climate change and ensures affordable and clean energy for all while protecting the climate in the context of the UN Sustainable Development Goals. The aim and innovation of our research is to develop energy multifunctional facades (EMFs) that are capable of performing a dual role, which includes the primary known energy functions of end elements and the additional innovative ability to serve as a source of heat/cooling/electricity. This new function of EMFs will facilitate heat dissipation from overheated facade surfaces, preheating of hot water, and electricity generation for the operation of building energy systems through integrated photovoltaic components. The theoretical assumptions and hypotheses presented in our previous research work must be verified by experimental measurements with predictions of the optimal operation of building energy systems. Most existing studies on thermal barriers are based on calculations. However, there are few empirical measurements that quantify the benefits of ATP in real operation and specify the conditions under which different types of ATP are feasible. In this article, we present the development, design, and implementation of an experimental prototype of a prefabricated building module with integrated energy-active elements. The aim is to fill the knowledge gaps by providing a comprehensive framework that includes the development, research, design, and implementation of combined energy systems for buildings. The design of energy systems will be developed in BIM. An important result of this research is the development of a technological process for the implementation of a contact insulation system with integrated ATP in modular and panel buildings with a lightweight envelope.
2 September 2025 in Journal of Thermal Analysis and Calorimetry
In this thesis, we present alternative ventilation solutions with heat recovery to reduce energy consumption in apartment buildings: decentralised ventilation compared to local ventilation. The aim is to analyse, evaluate, and optimise the operation of mechanical ventilation. The parametric study of energy, economic, and environmental calculations focuses first on a single apartment and then on the entire apartment building. Local heat recovery units have been designed for the ventilation of the apartment building. The share of heat loss through ventilation is 45% of the total design heat output for heating the building. Considering the UN Sustainable Development Goals, particularly Goal 7 (affordable and clean energy), we evaluated an alternative using decentralised heat recovery units with enthalpy heat exchangers. This approach achieved significant thermal energy savings, covered heat losses due to ventilation, and provided improved air and environmental quality in the apartment building. In this case, the share of ventilation heat losses in the apartment building is only 13% of the total design heat output of the building. The total heat output of the heat source was reduced by almost 78.78 kW, and the energy savings of the decentralised units amounted to 151.30 MWh, a reduction of 44% compared to the local ventilation units. Although the initial investment cost is about 45% higher than for the local units, the return on investment is achieved within 6 years of operation. The proposed solution represents a 58% saving in primary energy for ventilation and an 81% reduction in CO 2 emissions.
The thermal energy consumption for heating objects is one of the main parameters deciding their technical and structural solution. Reducing energy consumption is realized in various ways. The most used method is passive thermal protection, that is, increasing the thermal insulation parameters of the envelope constructions and optimizing the operation of the technical equipment of the buildings. There are also methods of active thermal protection to reduce heat leakage through non-transparent parts of the building envelope. Active thermal protection (ATP) is a dynamic process that applies primarily to building structures with integrated energetically active elements that fulfill one or more functions in mutually exclusive operating modes of energy systems and heat sources, such as thermal barriers (TB), large-scale heating/cooling, long-term heat/cool storage, capturing solar energy, and energy from the surroundings or even recovering heat in the cold season or cold in the warm season and other combinations. The research area focuses on analyzing active thermal protection’s energy potential. The methodology is based on a parametric study of dynamic thermal resistance (DTR), and heat flows to the interior and exterior from ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks. Such constructions generally show a consistently high DTR of 11.8 to 30.8 ((m2·K)/W) at a low mean heat transfer temperature of 10 to 16 °C, corresponding to the thermal insulation of 300 to 1000 mm. In the case of ATP storage heating with an average temperature of the heat-carrying substance of 30 °C, the heat flow into the interior of the investigated structure would be only 2.31 W/m2. Therefore, they are only suitable for a thermal barrier and heat/cold accumulation. Based on the synthesis and induction of analogical forms of the results of previous research into recommendations for the design of individual energy functions of ATP for perimeter structures of buildings, we present heat flows to the interior/exterior when changing the material of the layers towards the interior from ATP and describe possible variants of the development of building structures with integrated energetically active elements.
1 March 2023 in Slovak Journal of Civil Engineering
The case study analyses a specifically described situation from the present and a summary of events from the past, finds alternative solutions, and decides on one of them. The target of such a detailed analysis was a concrete apartment building, which was still in the project phase; the efforts to change its proposed air conditioning system to a more energy-efficient one are the subject of the case study. Apartment buildings with modern technology installed in terms of sanitary equipment, heating, and simple methods of ventilation and cooling do not constitute part of the project. Through a detailed analysis of the calculation of the heat losses through ventilation in the case of local and decentralised ventilation applied to one apartment unit, this failure to address modern solutions is remedied.