The article focuses on the description of an innovative solution and application of active thermal protection of buildings using thermal insulation panels with active regulation of heat transfer in the form of a contact insulation system. The thermal insulation panels are part of a prefabricated lightweight outer shell, which together with the low-temperature heating and high-temperature cooling system creates an indoor environment. The energy source is usually renewable energy sources or technological waste heat. Research and development of an innovative facade system with active thermal protection is in the phase of computer simulations and preparation of laboratory measurements of thermal insulation panels with various combinations of energy functions. In the article we present theoretical assumptions, calculation procedure and parametric study of three basic design solutions of combined energy wall systems in the function of low-temperature radiant heating and high-temperature radiant cooling.
This article focuses on the investigation of the dynamic thermal barrier (TB) and dynamic thermal resistance (DTR) of the building envelope. The aim is to analyze the DTR as a function of the temperature change of the heat transfer medium supplied to the dynamic TB layer and to determine the energy potential of several materially different fragments of the building envelope. The functions of TB and DTR depend on the uniform and continuous maintenance of temperature in a given layer of the building structure. The methodology is based on the analysis and synthesis of thermal resistance calculation, wall heating, and computer simulation. The research results show that the relatively low mean temperature of the heat transfer medium of approximately θm = 17 °C delivered to the TB layer represents RDTR = up to 30 ((m2·K)/W) for an equivalent dynamic thermal insulation thickness of 1000 mm for a required standard resistance of RSTANDARD = 6.50 ((m2·K)/W) of the individual fragments analyzed with static thermal insulation of 65 to 210 mm. The energy potential of a thermal barrier (TB) represents an increase of approximately 500% in the thermal resistance and up to 1500% in the thickness of the dynamic thermal insulation. Further research on the dynamic thermal barrier and verification of the results of the parametric study will continue with comprehensive computer simulations and experimental measurements on the test cell.
Thermal engineering requirements for building structures are becoming more and more strict. Thermal barriers (TBs) are energy-active elements integrated into the building structure in which a heat transfer medium (water or air) flows. A survey of the scientific literature on the subject points to the fact that this is a very topical and promising area of research and, so far, most studies on TBs are based on calculations, computer simulations and experimental measurements. Few studies have focused on the economic and environmental aspects of TB use. Following the research results presented by authors from all over the world, as well as our contributions in this scientific field that are described in a European patent, three utility models and scientific articles, in this study we have focused on the evaluation of the TB in terms of energy performance, economic efficiency and environmental friendliness by comparing the use of a classical envelope wall with the required thickness of thermal insulation meeting the normative requirements for thermal resistance R ((m2K)/W) and a perimeter wall with an integrated TB significantly eliminating the thermal insulation thickness. We evaluate the use of the thermal barrier using: economic indicator one, where we compare the cost of heat delivered to the TB in a structure with significantly eliminated thermal insulation and the saved cost of thermal insulation at the standard thickness; economic indicator two, where we compare the cost of heat delivered to the TB in a structure with significantly eliminated thermal insulation with the potential gain from the sale of the useful area of the building gained compared to the area at the normative thickness of thermal insulation; and economic indicator three, where we compare the cost of heat delivered to the TB in a structure with significantly eliminated thermal insulation with the cost of grey energy at the normative thickness of thermal insulation. Based on a parametric study based on theoretical assumptions, it can be concluded that the thermal barrier shows a very promising and efficient solution in terms of the evaluation of economic indicators one to three, which are even more significant if we use heat for the TB from renewable energy sources (RES) or waste heat.
The integration of energy-active elements into the building envelope in the form of large-area heating/cooling, active thermal protection (ATP), thermal barriers (TB), and TABS represents a technical solution that is consistent with the principles of energy sustainability, resilience, and adaptability to climate change and ensures affordable and clean energy for all while protecting the climate in the context of the UN Sustainable Development Goals. The aim and innovation of our research is to develop energy multifunctional facades (EMFs) that are capable of performing a dual role, which includes the primary known energy functions of end elements and the additional innovative ability to serve as a source of heat/cooling/electricity. This new function of EMFs will facilitate heat dissipation from overheated facade surfaces, preheating of hot water, and electricity generation for the operation of building energy systems through integrated photovoltaic components. The theoretical assumptions and hypotheses presented in our previous research work must be verified by experimental measurements with predictions of the optimal operation of building energy systems. Most existing studies on thermal barriers are based on calculations. However, there are few empirical measurements that quantify the benefits of ATP in real operation and specify the conditions under which different types of ATP are feasible. In this article, we present the development, design, and implementation of an experimental prototype of a prefabricated building module with integrated energy-active elements. The aim is to fill the knowledge gaps by providing a comprehensive framework that includes the development, research, design, and implementation of combined energy systems for buildings. The design of energy systems will be developed in BIM. An important result of this research is the development of a technological process for the implementation of a contact insulation system with integrated ATP in modular and panel buildings with a lightweight envelope.
The research described in this study focuses on the innovation and optimization of building envelope panels with integrated energy-active elements in the thermal barrier function. It is closely related to developing and implementing the prototype prefabricated house IDA I with combined building-energy systems using renewable energy sources. We were inspired by the patented ®ISOMAX panel and system, which we have been researching and innovating for a long time. The thermal barrier has the function of eliminating heat loss/gain through the building envelope. By controlling the heat/cold transfer in the thermal barrier, it is possible to eliminate the thickness of the thermal insulation of the building envelope and thus achieve an equivalent thermal resistance of the building structure that is equal to the standard required value. The technical solution of the ISOMAX panel also brings, besides the use of the thermal barrier function, the function of heat/cold accumulation in the load-bearing part of the building envelope. Our research aimed to design and develop a panel for which the construction would be optimal in terms of thermal barrier operation and heat/cold accumulation. As the production panels in the lost formwork of expanded polystyrene (according to the patented system) proved to be too complicated and time consuming, and often showed shortcomings from a structural point of view, the next goal was to design a new, statically reliable panel construction with integrated energy-active elements and a time-saving, cost-effective, unified production directly in the panel factory. In order to develop and design an innovative panel with integrated energy-active elements, we analyzed the composition of the original panel and designed the composition of the innovative panel. We created mathematical–physical models of both panels and analyzed their energy potential. By induction and an analog form of formation, we designed the innovative panel. Based on the synthesis of the knowledge obtained from the scientific analysis and the transformation of this data, most of the building components and all the panels with integrated energy-active elements were manufactured directly in the prefabrication plant. Subsequently, the prototype of the prefabricated house IDA I was realized. The novelty of our innovative building envelope panel solution lies in the panel’s design, which has a heat loss/gain that is 2.6 times lower compared to the ISOMAX panel.