Magnetic field imaging (MFI) is widely used in electromagnetic nondestructive evaluation (ENDE). This paper presents a high-density, large-scale tunneling magnetoresistance (TMR) sensor array for MFI applied in ENDE. The TMR array consists of 180 sensing elements with the distance of 0.5 mm between any pair of TMR sensors adjacent to each other, which enables to acquire an image with high spatial resolution. With a total length of 90 mm, the TMR array is capable of imaging a rectangular area as wide as 90 mm in a single scan resulting in a fast inspection speed for the evaluation of structure with a large surface area. The proposed TMR sensor array has high sensitivity to the magnetic field in a wide frequency range. Therefore, it can be used for the detection of deeply embedded defects in multilayer riveted structures with excitation currents at ultralow frequencies. Experimental results show that machined notches under fasteners head at a distance of 8 mm from the top surface of a multilayer riveted aluminum structure can be detected with a proper fusion of the magnetic field images at 100 and 1000 Hz. Furthermore, surface notch with dimension 300 μ m x 300 μ m x 400 μ m on an aluminum sample can be detected from the obtained magnetic field image with excitation current frequency 20 kHz.
28 April 2020 in IEEE Transactions on Industrial Electronics
Three-axis components of magnetocardiography (MCG) signals are measured with a high sensitivity tunnel magnetoresistance (TMR) sensor in this paper. From the measurement result, the R-wave and QRS-complex of MCG associated with the cardiac cycle are clearly observable without need of averaging. The T-wave is at the noise level and the weaker P-wave is drowned in noise. It is a great progress comparing with previous MCG measurement with TMR sensor, where averaging was required to reliably detect R-wave. The amplitude of R-peak observed by the TMR sensor in x direction is 200 pT, which is consistent with the measurement of superconducting quantum interference device (SQUID) considering the effect of distance from the observation point to the magnetic field source. The y and z components R-peak are about 550 pT. As the TMR sensor can measure MCG at room temperature, potentially it is a promising alternative to cryogenically-cooled superconducting devices to make inexpensive MCG instrumentation for extensive clinical applications.
14 January 2021 in IEEE Transactions on Industrial Electronics
It is critical for maintaining the safe operation of turbine blades to inspect the potential structural damages promptly. However, the industry still lacks efficient tools for inspection of the curved surface. In this respect, in this article, a new flexible probe with in-plane differential coils is proposed. With the sophisticated configuration, the probe has four channels, which complement each other in terms of sensitivity to defects of different orientations. The in-plane differential scheme nulls the background signal and reduces the noise resulting in high sensitivity to microdefects. The probe can be bent according to the curved surface due to its flexible configuration. A three-dimensional finite-element method model based on the cluster parallel computation is utilized to study the feasibility and performance of the probe, and a prototype probe is developed and tested by scanning defects on the curved surface of a turbine blade sample. Furthermore, a data fusion method is proposed to obtain a better signal-to-noise ratio so that defects with length*width*depth = 2.5 mm*0.1 mm*0.1 mm can be identified. Based on repeated experiments, it is observed that the probability of detection with the fusion of the multichannels is higher than that of every single channel demonstrating that the data fusion increases the reliability of the inspection.
Array eddy current testing (AECT) sensor is capable of inspecting a large area in a single probe pass resulting in a C-scan image, which is beneficial for customizing the profile of the part being inspected. This paper presents a novel AECT sensor with three-phase excitation. The sensor has two rows of excitation coils and a row of pickup coils. The excitation coils are driven by three-phase currents that are 120° apart in phase. The induced eddy current in the conductive sample shifts electrically along the phase variation direction of the excitation currents. As a result, the sensor does not need multiplexer resulting in advantages of lower cost, less noise and faster inspection speed. The background signal measured by the sensor is small if there is no defect in the sample. Therefore, the sensor has high relative sensitivity to the presence of defect. A 3D finite element method (FEM) model is utilized to study the operating principle of the sensor. A prototype sensor has been developed and tested, with which aluminum sample and carbon fiber reinforced polymer (CFRP) sample with machined defects are inspected. The experiment results demonstrate the feasibility of the sensor for fast imaging of conductive materials.
6 April 2021 in IEEE Transactions on Antennas and Propagation
In this work, a new technique to characterize a microwave orbital angular momentum (OAM) beam applying a single-sensor compressive imaging (SSCI) strategy is reported, which is much more time-efficient, cost-effective, and compact than traditional near-field scanning methods. A microwave spatial wave modulator (MSWM) realized by a programmable metasurface is applied to generate random mask patterns and modulate an OAM beam under test. The modulated fields are collected by a single-sensor detector. Two different algorithms can be used to reconstruct phase and magnitude profiles of the OAM beam, with the first one demands both amplitude and phase measurement while the second one only perceives the amplitude or intensity. Simulations are first carried out to investigate the effects of several parameters of the random mask patterns on the quality of reconstruction. Proof-of-concept experiments are then performed to characterize a microwave OAM beam, and obtained results show high-quality reconstructed phase and magnitude distributions of the OAM beam under test, which corroborates the effectiveness of the proposed SSCI technique. This work establishes an alternative paradigm for fast and economic measurement of microwave and millimeter-wave OAM beams. It may also facilitate OAM-based communication applications.