It is critical for maintaining the safe operation of turbine blades to inspect the potential structural damages promptly. However, the industry still lacks efficient tools for inspection of the curved surface. In this respect, in this article, a new flexible probe with in-plane differential coils is proposed. With the sophisticated configuration, the probe has four channels, which complement each other in terms of sensitivity to defects of different orientations. The in-plane differential scheme nulls the background signal and reduces the noise resulting in high sensitivity to microdefects. The probe can be bent according to the curved surface due to its flexible configuration. A three-dimensional finite-element method model based on the cluster parallel computation is utilized to study the feasibility and performance of the probe, and a prototype probe is developed and tested by scanning defects on the curved surface of a turbine blade sample. Furthermore, a data fusion method is proposed to obtain a better signal-to-noise ratio so that defects with length*width*depth = 2.5 mm*0.1 mm*0.1 mm can be identified. Based on repeated experiments, it is observed that the probability of detection with the fusion of the multichannels is higher than that of every single channel demonstrating that the data fusion increases the reliability of the inspection.
This paper presents an eddy current probe with array tunnel magnetoresistance (TMR) sensors for inspection of steam generator tube of nuclear power plant. The TMR sensors are integrated on a circular printed circuit board (PCB) with the sensitive axis along the radius directions. The dimensions of each TMR sensor in the array are length (0.45 mm) * width (0.45 mm). Fine spatial resolution magnetic field imaging can be generated as the size of the sensor is small. The operating principle of the probe is based on Faraday’s law, where eddy current is induced in the tube wall by an excitation coil carrying AC current, and then the disturbance of the eddy current is monitored in terms of magnetic field measured by the TMR sensors. Thanks to the high sensitivity and fine spatial resolution of the TMR sensors, the probe is capable of detecting outer diameter (OD) defect with effective size 0.127 mm×0.436 mm. Moreover, when the probe scans in a defect-free area, the variation of lift-off of the probe to the inner surface of the tube wall does not bring in noises, which is important for maintaining a high signal-to-noise ratio in practical inspection. The operation principle of the probe was studied based on a finite element method (FEM) model, and then a prototype unit was developed and tested. Experimental results demonstrated the feasibility of the concept, and validated that the probe has excellent ability of detecting various defects.
26 July 2021 in IEEE Transactions on Instrumentation and Measurement
Inspection of defects in weld has both safety and economic significance in industries. However, it is still a challenging problem to be studied due to the interference of the uneven surface of the weld and nonuniformity of the material. This article proposes a new flexible eddy current testing (ECT) probe with differential multimodes for weld inspection. The probe is constructed based on a flexible printed circuit board (PCB). Consequently, it can be bended according to the uneven surface of a weld sample. The differences of pairs of coils are recoded as the outputs of the probe, in which the common mode noises and background signals are canceled. Considering the different orientations of the differential pair coils, the probe has four modes. Different modes complement each other in terms of sensitivity to different kinds of defects. The effect of the excitation frequency has been studied, and 1 MHz is chosen as the operating frequency of the probe. An image preprocessing algorithm called spatial domain filtering and gradient feature edge extraction (SDF-GFEE) is proposed for suppressing the noise of the experimental images. A target detection algorithm based on deep neural network named mask region convolution neutral network (Mask-RCNN) is utilized to identify defects from the images. Experimental results demonstrate that this method is capable of identifying the groove defect with dimensions 3 mm (length) ×0.1 mm (width) ×0.5 mm (depth) and flat bottom hole with dimensions Φ0.8 mm ×0.5 mm in a weld sample.
Tunnel magnetoresistance (TMR) is a kind of magnetic sensor with the advantages of low cost and high sensitivity. For ultra-weak and low-frequency magnetic field measurement, the TMR sensor is affected by the 1/f noise. This paper proposes an AC modulation method with impedance compensation to improve the performance. The DC and AC characteristics of the sensors were measured and are presented here. It was found that both the equivalent resistance and capacitor of the sensors are affected by the external magnetic field. The TMR sensors are connected as a push–pull bridge circuit to measure the magnetic field. To reduce the common-mode noise, two similar bridge circuits form a magnetic gradiometer. Experimental results show that the sensor’s sensitivity in the low-frequency range is obviously improved by the modulation and impedance compensation. The signal-to-noise ratio of the sensor at 1 Hz was increased about 25.3 dB by the AC modulation, impedance compensation, and gradiometer measurement setup. In addition, the sensitivity of the sensor was improved from 165.2 to 222.1 mV/V/mT. Ultra-weak magnetic signals, namely magnetocardiography signals of two human bodies, were measured by the sensor in an unshielded environment. It was seen that the R peak of MCG can be clearly visualized from the recorded signal.
Accurately measuring transformer DC bias current is crucial due to its significant impact on the operational stability of the power system. It is difficult for existing technologies to balance the requirements of high sensitivity, reliability and convenient installation. This paper presents a non-contact Direct Current (DC) bias current measurement probe using tunnel magnetoresistance (TMR) sensor arrays. The probe contains 16 sensors, which are divided into four arrays. The sensors are bare die chips diced from an 8-inch wafer and then wire bonded on a printed circuit board. The distance between two adjacent sensors in an array is only 0.5 mm, resulting in approximately uniform magnetic field gradient for the sensors simplifying the calculation of the output. The sensors are connected as a push-pull Wheatstone bridge to convert the change of resistances to a voltage signal and to enhance the sensitivity. The distribution of the magnetic field is calculated numerically and the Shannon entropy of the signals are estimated. Then the output signals are fused based on weights calculated according to the magnetic field distribution and the Shannon entropy. This method allows for a balanced integration of both the linear characteristics of the signal and its intrinsic properties. Experimental results demonstrate that the system achieves a relative linearity error less than 0.95% for measuring DC currents in the range from -3000mA to 3000mA. This method is an alternative approach that can be utilized in the power system to monitor the transformer DC bias current.