Background: Remote dielectric sensing (ReDS™) is an electromagnetic-based technology used to noninvasively measure lung fluid levels. The association between ReDS values and invasively measured hemodynamics, particularly among those with small physics, remains unknown. Methods: Consecutive patients with chronic heart failure who were admitted to our institute and underwent invasive right heart catheterization as well as simultaneous ReDS measurement at clinically stable conditions between September and November 2021 were prospectively included. The colinearity between ReDS values and pulmonary capillary wedge pressure was studied. Results: In total, 30 patients (median 79 (73, 84) years old, 13 men) were included. Median ReDS value was 26% (22%, 28%). ReDS values had a moderate collinearity with pulmonary capillary wedge pressure (r = 0.698, p < 0.001), even among those with a body height < 155 cm. ReDS values with a cutoff of 28% predicted a pulmonary capillary wedge pressure > 15 mmHg with sensitivity 0.70 and specificity 0.75. Conclusions: An electromagnetic-based engineering ReDS might be a potential tool to estimate cardiac pressure in patients with heart failure, including those with small physics.
Background: The accuracy of the remote dielectric sensing (ReDSTM) system, which is a noninvasive electromagnetic-based technology to quantify lung fluid levels, particularly among those with small body size, remains uncertain. Methods: Hospitalized patients with and without heart failure underwent assessment of lung fluid levels with ReDS and successive chest computed tomography imaging. We performed a correlation analysis of the ReDS measurement, representing lung fluid levels, and computed tomography-derived high attenuation area percentage, which also provides a spatial quantification of lung fluid level. Results: A total of 46 patients (median 76 years old, 28 men), including 28 patients with heart failure, were included. The median ReDS value was 28% (interquartile: 23%, 33%), and the median percentage of high attenuation area was 21.6% (14.4%, 28.5%). ReDS values and percentage of high attenuation area were moderately correlated (r = 0.65, p < 0.001), irrespective of the existence of heart failure. ReDS value independently predicted the percentage of high attenuation area seen on computed tomography (p < 0.001). Conclusions: The ReDS system may be a promising, noninvasive tool to quantify fluid lung levels, as validated by comparison with chest computed tomography imaging. Further studies are warranted to validate the utility and applicability of this technology to a variety of clinical scenarios.
Background: Impella is a percutaneous transcatheter left ventricular assist device. Device-related hemolysis is a serious complication that is sometimes encountered depending on the device position, device speed, and support duration. However, the impact of hemodynamics on the occurrence of hemolysis remains unknown. In this study, we aimed to clarify the relationships between hemodynamics, especially right ventricular function, and the occurrence of hemolysis during Impella-incorporated mechanical circulatory support. Methods: Consecutive patients who received Impella (2.5, CP, and 5.0) support at our institute between March 2018 and July 2021 were retrospectively included. The relationships between the pulmonary artery pulsatility index (PAPi) immediately after Impella insertion and the occurrence of hemolysis were investigated. Results: Forty-two patients (median 71 years old, 60% men) were included. Hemolysis occurred in 20 patients (48%). A cutoff of PAPi to predict hemolysis was calculated as 1.3, with 80.0% sensitivity and 72.7% specificity. Lower PAPi (<1.3) significantly correlated with the occurrence of hemolysis with an odds ratio of 11.65 (95% confidence interval 1.58–85.98, p = 0.017), adjusted for other potential confounders. Survival discharge was significantly lower in patients with lower PAPi (<1.3) (50% vs. 86%, p = 0.019). Conclusions: The results of this study suggest that patients with right ventricular impairment indicated by lower PAPi following the initiation of Impella-incorporated mechanical circulatory support have a higher risk of hemolysis.
Background: Sodium–glucose cotransporter 2 inhibitors (SGLT2i) reduce mortality and morbidity in patients with heart failure (HF), but are discontinued in some patients. Such patients may not enjoy favorable benefits of SGLT2i therapy. We evaluated the risk factors for SGLT2i discontinuation in a real-world population with HF. Methods: We retrospectively included consecutive patients who were hospitalized for HF and administered SGLT2i during the index hospitalization between February 2016 and September 2021. We assessed the baseline clinical factors associated with post-discharge discontinuation of SGLT2i. Results: This study included a total of 159 patients (median age = 73 years, 57 women). Among baseline characteristics, a lower serum albumin level (odds ratio = 0.23, 95% confidence interval = 0.07–0.76, p = 0.016) and a higher dose of furosemide (odds ratio = 1.02, 95% confidence interval = 1.00–1.05, p = 0.046) were independently associated with the future discontinuation of SGLT2i following index discharge. Patients who terminated SGLT2i (n = 19) had a higher incidence of HF recurrence or cardiovascular death during the 1-year therapeutic period (32% versus 11%, p = 0.020). Conclusions: Among patients who initiated SGLT2i during hospitalization for HF, lower serum albumin levels and higher doses of loop diuretic at index discharge were associated with the discontinuation of SGLT2i following index discharge. We should pay special attention to patients with such characteristics during the initiation of SGLT2i and during SGLT2i therapy.