Background: The accuracy of the remote dielectric sensing (ReDSTM) system, which is a noninvasive electromagnetic-based technology to quantify lung fluid levels, particularly among those with small body size, remains uncertain. Methods: Hospitalized patients with and without heart failure underwent assessment of lung fluid levels with ReDS and successive chest computed tomography imaging. We performed a correlation analysis of the ReDS measurement, representing lung fluid levels, and computed tomography-derived high attenuation area percentage, which also provides a spatial quantification of lung fluid level. Results: A total of 46 patients (median 76 years old, 28 men), including 28 patients with heart failure, were included. The median ReDS value was 28% (interquartile: 23%, 33%), and the median percentage of high attenuation area was 21.6% (14.4%, 28.5%). ReDS values and percentage of high attenuation area were moderately correlated (r = 0.65, p < 0.001), irrespective of the existence of heart failure. ReDS value independently predicted the percentage of high attenuation area seen on computed tomography (p < 0.001). Conclusions: The ReDS system may be a promising, noninvasive tool to quantify fluid lung levels, as validated by comparison with chest computed tomography imaging. Further studies are warranted to validate the utility and applicability of this technology to a variety of clinical scenarios.
Background: Sodium–glucose cotransporter 2 inhibitors (SGLT2i) reduce mortality and morbidity in patients with heart failure (HF), but are discontinued in some patients. Such patients may not enjoy favorable benefits of SGLT2i therapy. We evaluated the risk factors for SGLT2i discontinuation in a real-world population with HF. Methods: We retrospectively included consecutive patients who were hospitalized for HF and administered SGLT2i during the index hospitalization between February 2016 and September 2021. We assessed the baseline clinical factors associated with post-discharge discontinuation of SGLT2i. Results: This study included a total of 159 patients (median age = 73 years, 57 women). Among baseline characteristics, a lower serum albumin level (odds ratio = 0.23, 95% confidence interval = 0.07–0.76, p = 0.016) and a higher dose of furosemide (odds ratio = 1.02, 95% confidence interval = 1.00–1.05, p = 0.046) were independently associated with the future discontinuation of SGLT2i following index discharge. Patients who terminated SGLT2i (n = 19) had a higher incidence of HF recurrence or cardiovascular death during the 1-year therapeutic period (32% versus 11%, p = 0.020). Conclusions: Among patients who initiated SGLT2i during hospitalization for HF, lower serum albumin levels and higher doses of loop diuretic at index discharge were associated with the discontinuation of SGLT2i following index discharge. We should pay special attention to patients with such characteristics during the initiation of SGLT2i and during SGLT2i therapy.
There is a consensus that overactivation of the cardiac sympathetic nervous system (CSN) proportionately increases the severity of heart failure and is accompanied by worse prognosis. Because it is unknown whether patients with aortic valve stenosis (AS) have similar CSN activation, we investigated the effect of transcatheter aortic valve implantation (TAVI).Methods and Results:We enrolled 31 consecutive patients with AS treated by TAVI. 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed at baseline and at 2 weeks after TAVI. At baseline, the early heart-mediastinum ratio (H/M) was within normal limits (3.0±0.5), but the delayed H/M was low (2.6±0.6) and the washout rate (WR) was high (34±13%). WR negatively correlated with aortic valve area (r=-0.389, P<0.01) and cardiac output (r=-0.595, P<0.01) and positively correlated with norepinephrine (r=0.519, P<0.01) and log NT-proBNP level (r=0.613, P<0.01). After TAVI, there were significant decreases in the norepinephrine level (366±179 ng/mL vs. 276±125 ng/mL, P<0.01) and WR (34±13 vs. 26±11%, P<0.01). The WR of MIBG was a useful marker of CSN activity and severity of AS. Immediate improvement of CSN activity after TAVI implied that AS hemodynamics per se enhanced CSN.
Background: Psoas muscle mass is a recently featured index of sarcopenia, which has a negative prognostic impact in patients with a variety of diseases. We investigated the prognostic impact of baseline psoas muscle mass in patients receiving a trans-catheter aortic valve replacement (TAVR). Methods: Patients who received TAVR at our center between 2015 and 2022 were included. Patients received computer tomography imaging upon admission as an institutional protocol, and psoas muscle mass was measured, which was indexed by body surface area. Patients were followed for four years or until January 2023. The prognostic impact of psoas muscle mass index on 4-year mortality following index discharge was evaluated. Results: A total of 322 patients (85 years, 95 male) were included. Median psoas muscle mass index at baseline was 10.9 (9.0, 13.5) × 10 cm3/m2. A lower psoas muscle mass index tended to be associated with several index of malnutrition and sarcopenia. A psoas muscle mass index was independently associated with 4-year mortality with an adjusted hazard ratio of 0.88 (95% confidence interval 0.79–0.99, p = 0.044). Patients with lower psoas muscle mass index (below the statistically calculated cutoff of 10.7 × 10 cm3/m2, N = 152) had significantly higher cumulative 4-year mortality compared with others (32% versus 13%, p = 0.008). Conclusions: A lower psoas muscle mass index, which is a recently featured objective marker of sarcopenia, was associated with mid-term mortality following TAVR in the elderly cohort with severe aortic stenosis. The measurement of psoas muscle mass index prior to TAVR could have clinical implications for shared decision-making among patients, their relatives, and clinicians.
Background: The six-minute walk test is a practical tool for assessing functional capacity in patients with a variety of etiologies including pulmonary disease and heart failure. Six-minute walk distance (6MWD) is associated with mortality and morbidity in patients with a variety of comorbidities. We aimed to assess the prognostic impact of baseline 6MWD in patients with severe aortic stenosis undergoing trans-catheter aortic valve replacement (TAVR). Methods: Patients with severe aortic stenosis who underwent a six-minute walk test after index admission and underwent TAVR between 2015 and 2022 were included in this retrospective study. Patients were followed up for two years or until November 2022 following TAVR. The impact of baseline 6MWD on the primary composite outcome, defined as all-cause death and all-cause readmission during the 2-year observation period following index discharge, was assessed. Results: A total of 299 patients (median age 86 years old, 85 men) were included. They received a 6-min walk test prior to TAVR, underwent successful TAVR procedures, and were discharged alive. The median baseline 6MWD was 204 (143, 282) meters. Shorter baseline 6MWD was associated with higher cumulative incidence of the primary outcome with an adjusted hazard ratio of 0.76 (95% confidence interval 0.58–1.01, p = 0.055) with a cutoff 6MWD of 178 m during the 2-year observation period after index discharge. Conclusions: Overall, functional capacity was impaired in the elderly patients with severe aortic stenosis prior to TAVR. Patients with severe aortic stenosis having shorter baseline 6MWD tended to have higher rates of morbidity and mortality after successful TAVR. The clinical implication of aggressive cardiac rehabilitation to improve patients’ functional capacity and 6MWD-guided optimal patient selection remain the future concerns.