The compositive passive control (CPC) method of “interlayer seismic isolation “plus “shock absorption between adjacent towers” was applied to a multi-tower building (MTB) with a large podium. The interaction between adjacent towers was used to reduce the structural response under seismic action. Based on the Clough–Penzien spectral seismic model, the extended state equation of random response of MTB was derived with the minimum total energy of structural vibration as the optimization control objective. By comparing the seismic scheme and interlayer seismic isolation scheme, the relationship between the control parameters of the connecting control device and the random response of the structure was discussed and analyzed, and the control effect of the composite passive control system under different control schemes was also studied from the perspective of seismic response time history and vibration cumulative energy time history. Through numerical analysis, it was proved that the damping coefficient of the Kelvin-Voigt model has a great influence on the mean square error of total vibration energy while the stiffness coefficient has a poor sensitivity to it. Under the optimization control objective, the connection control device was better arranged at the top of the structure. The control effect can reach 84.64% under the condition of random ground motion as input. The CPC method maintains the advantages of the interlayer seismic isolation scheme and reduces the defect of the response amplification caused by the interlayer isolation, which provides a reference for the follow-up study of the CPC method of MTB.
The qualitative analysis for structural robustness study subjected to severe earthquakes is unable to meet engineering requirements, and a quantitative analysis method for structural robustness is needed to be proposed. The existing analysis methods, such as Incremental Dynamic Analysis Method and Pushover method, only study the response of the structure directly from the macroscopic view, rather than focusing on the response of a single component on the structure. Especially for the construction of isolated structure, the impact of accidental bearing failure on the isolated structure and the impact of progressive collapse cannot be considered. In this paper, based on the Alternative Load Path Method, the quantitative analysis method for structural robustness analysis under earthquake is proposed. The structural robustness of some different vertical irregular isolated structures under different earthquakes is studied.
Study on seismic dissipation mechanism of inter-story isolation structure based on phase Owing to the existence of the isolation layer, a phase lag phenomenon occurs between the superstructure and substructure of a story isolation structure. This phenomenon causes a phase difference between the superstructure and substructure; furthermore, the generated phase difference has a significant impact on the structural damping effect. To study this effect, we established a two-mass model of an inter-story isolated structure, derived the phase difference formula, analysed the impact of the phase difference on the damping effect of the modelled inter-story isolated structure and obtained the optimal phase difference to achieve the best damping effect; in addition, we combined the principle of minimum base shear and optimal phase difference to optimise the damping of the structural isolation layer with different mass ratios. Based on the optimal damping, an energy balance equation was established from the viewpoint of energy. The energy transfer and consumption under different phase differences were analysed to further discuss the relationship between phase differences and the damping effect of the interstory isolated structure.