Uneven foundation settlement is one of the common engineering problems in a collapsible loess area. In order to study the influence of uneven foundation settlement on the seismic performance of a structure, the incremental dynamic analysis (IDA) method is used to analyze the seismic vulnerability of the steel structure frame. The differences in the seismic response of the structure in relation to uneven foundation settlement are analyzed. The influences of uneven foundation settlement quantities and various areas of uneven settlement on the seismic response of the structure are discussed. On this basis, the relationship between ground motion intensity and structural failure probability is studied, by changing the magnitude of seismic acceleration peaks. Compared with the unsettled structure, the internal force redistribution of the structure caused by uneven foundation settlement is one of the causes of earthquake damage for some components. The uneven foundation settlement located at the corner of the plane of the structure is likely to cause more serious earthquake damage to the structure. Uneven settlement will cause an increase in storey drift. With the increase in settlement, the seismic damage of the superstructure will be aggravated.
The qualitative analysis for structural robustness study subjected to severe earthquakes is unable to meet engineering requirements, and a quantitative analysis method for structural robustness is needed to be proposed. The existing analysis methods, such as Incremental Dynamic Analysis Method and Pushover method, only study the response of the structure directly from the macroscopic view, rather than focusing on the response of a single component on the structure. Especially for the construction of isolated structure, the impact of accidental bearing failure on the isolated structure and the impact of progressive collapse cannot be considered. In this paper, based on the Alternative Load Path Method, the quantitative analysis method for structural robustness analysis under earthquake is proposed. The structural robustness of some different vertical irregular isolated structures under different earthquakes is studied.
The progressive collapse of the structure caused by the partial failure of the structure will cause severe consequences and massive losses, and structural progressive collapse resistance has always been a hot topic of current research. In order to study the progressive collapse mechanism of base-isolated structures, the test study and numerical simulation of the base-isolated structures were carried out based on the vertical Pushover method and analysis of the variation rule of the capacity of the remaining structure and influence mechanism. The isolation bearing failure position, the size of the beam of the seismic isolation layer, the type of the isolation bearing, and the horizontal stiffness of the seismic isolation layer on the capacity of the remaining structure were compared and analyzed. The results show that the non-uniformity of the beams and the concentrated loading at the nodes were easy to form a linear catenary mechanism, resulting in more severe beam end damage than mid-span damage. In the case of side isolation bearing failure, due to the lack of sufficient lateral restraint, the capacity was significantly lower than other conditions, which were more likely to cause partly collapse. Therefore, setting more transfer paths to improve the structure’s resistance to progressive collapses was necessary. Increasing the size of the beam of the seismic isolation layer could improve the capacity of the remaining structure of the alternate load path in the base-isolated structure. The changes in the horizontal stiffness of the seismic isolation layer and the type of the isolation bearing have little effect on the progressive collapse resistance capacity of the remaining structure.