Petr Simonik

Dr. Petr Simonik

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MSMichaela Sidikova
Michaela Sidikova
Radek MartinekRadek Martinek
Radek Martinek
AKAleksandra Kawala-Sterniuk
Aleksandra Kawala-Sterniuk
MLMartina Ladrova
Martina Ladrova
RJRene Jaros
Rene Jaros
PSPetr Simonik
Petr Simonik
This paper focuses on a thorough summary of vital function measuring methods in vehicles. The focus of this paper is to summarize and compare already existing methods integrated into car seats with the implementation of inter alia capacitive electrocardiogram (cECG), mechanical motion analysis Ballistocardiography (BCG) and Seismocardiography (SCG). In addition, a comprehensive overview of other methods of vital sign monitoring, such as camera-based systems or steering wheel sensors, is also presented in this article. Furthermore, this work contains a very thorough background study on advanced signal processing methods and their potential application for the purpose of vital sign monitoring in cars, which is prone to various disturbances and artifacts occurrence that have to be eliminated.

19 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JBJan Baros
Jan Baros
Vojtech SotolaVojtech Sotola
Vojtech Sotola
PBPetr Bilík
Petr Bilík
Radek MartinekRadek Martinek
Radek Martinek
RJRene Jaros
Rene Jaros
PSPetr Simonik
Petr Simonik
The field of advanced digital signal processing methods is one of the fastest developing scientific and technical disciplines, and is important in the field of Shunt Active Power Filter control methods. Shunt active power filters are highly desirable to minimize losses due to the increase in the number of nonlinear loads (deformed power). Currently, there is rapid development in new adaptive, non-adaptive, and especially hybrid methods of digital signal processing. Nowadays, modern methods of digital signal processing maintain a key role in research and industrial applications. Many of the best practices that have been used to control shunt active power in industrial practice for decades are now being surpassed in favor of new progressive approaches. This systematic research review classifies the importance of using advanced signal processing methods in the field of shunt active power filter control methods and summarizes the extant harmonic extraction methods, from the conventional approach to new progressive methods using genetic algorithms, artificial intelligence, and machine learning. Synchronization techniques are described and compared as well.

29 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
MKMartin Kuchar
Martin Kuchar
PPPetr Palacky
Petr Palacky
PSPetr Simonik
Petr Simonik
Jan StrossaJan Strossa
Jan Strossa
This paper introduces a new solution for the speed and current sensor fault-tolerant direct field-oriented control of induction motor drives. Two self-adjusting observers derived from a modified current-based model reference adaptive system (CB-MRAS) are presented. Finally, the recursive least squares method was used to estimate the parameters of the used observers. The method, in the proposed solution, provides a very fast and accurate finding of the observer parameters while maintaining relative simplicity and ease of implementation. The presented algorithm eliminates the CB-MRAS observer dependence on the induction motor parameters and also compensates for the inaccuracies in the evaluation of the stator voltage vector. The proposed fault-tolerant control offers the drive operation while either a speed sensor or one/two current sensors fault occurs. The drive still works with the direct field-oriented control even when no current sensors are healthy. The proposed scheme was simulated in the MATLAB/Simulink software environment. Then the algorithm was implemented in a floating-point digital signal controller (DSC) TMS320F28335 and tested on an induction motor drive prototype of rated power of 2.2 kW to validate the proposed schemes.

1 September 2006
Verified
Conference Paper
Closed access
LOLukas Osmancik
Lukas Osmancik
MPMartin Polak
Martin Polak
PSPetr Simonik
Petr Simonik
LHLibor Hrdina
Libor Hrdina
PSPetr Skotnica
Petr Skotnica
PPPetr Palacky
Petr Palacky
This paper deals with the application of the signal processor TMS320F2812 in electric drives. An interface is described for a kit with this signal processor. This interface was created at the Department of Power Electronics and Electrical Drives. Further, we discuss two practical applications: the first is the drive of a four-quadrant current source rectifier, the second is the drive of an induction motor with a three-level inverter.

1 July 2010
Verified
Conference Paper
Closed access
PBPavel Brandstetter
Pavel Brandstetter
LHLibor Hrdina
Libor Hrdina
PSPetr Simonik
Petr Simonik
Direct torque control is one of modern methods of A.C. machines control. The direct torque control methods have been developed and experimentally tested at the Department of Electronics too. In the paper, important quantities are described which were measured on a real induction motor drive with different direct torque control methods. The basic properties of the methods are compared with the Takahashi method.

1 November 2018
Verified
Conference Paper
Closed access
PSPetr Simonik
Petr Simonik
TMTomas Mrovec
Tomas Mrovec
SPSamuel Przeczek
Samuel Przeczek
THTomas Harach
Tomas Harach
TKTomas Klein
Tomas Klein
This paper deals with the concept of the braking system by wire. It composes of three parts: an electro-hydraulic ABS unit with additional sensors and actuators controlled by a master control unit, an integrated emergency brake and the applied brake control algorithms. Implementation took place on a quad bike called "Democar". It is equipped with control units such as electric drive control unit, steering control unit, lighting control unit, energy management control unit, and central control unit. All of the control units communicate with each other via CAN bus. The emergency brake is used in the event of a power failure or failure of the service brake system.