Michal Porizka

Dr. Michal Porizka

Department of Anaesthesiology and Intensive Care Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, Prague 12808, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
JBJan Bláha
Jan Bláha
MMMiloš Mráz
Miloš Mráz
PKPetr Kopecký
Petr Kopecký
MSMartin Stříteský
Martin Stříteský
MLMichal Lipš
Michal Lipš
MHMartin Haluzík
Martin Haluzík
Tight glucose control (TGC) reduces morbidity and mortality in patients undergoing elective cardiac surgery, but only limited data about its optimal timing are available to date. The purpose of this article was to compare the effects of perioperative vs postoperative initiation of TGC on postoperative adverse events in cardiac surgery patients. This was a single center, single-blind, parallel-group, randomized controlled trial. The setting was an academic tertiary hospital. Participants were 2383 hemodynamically stable patients undergoing major cardiac surgery with expected postoperative intensive care unit treatment for at least 2 consecutive days. Intensive insulin therapy was initiated perioperatively or postoperatively with a target glucose range of 4.4 to 6.1 mmol/L. Adverse events from any cause during postoperative hospital stay were compared. In the whole cohort, perioperatively initiated TGC markedly reduced the number of postoperative complications (23.2% vs 34.1%, 95% confidence interval [CI], 0.60-0.78) despite only minimal improvement in glucose control (blood glucose, 6.6 ± 0.7 vs 6.7 ± 0.8 mmol/L, P < .001; time in target range, 39.3% ± 13.7% vs 37.3% ± 13.8%, P < .001). The positive effects of TGC on postoperative complications were driven by nondiabetic subjects (21.3% vs 33.7%, 95% CI, 0.54-0.74; blood glucose 6.5 ± 0.6 vs 6.6 ± 0.8 mmol/L, not significant; time in target range, 40.8% ± 13.6% vs 39.7% ± 13.8%, not significant), whereas no significant effect was seen in diabetic patients (29.4% vs 35.1%, 95% CI, 0.66-1.06) despite significantly better glucose control in the perioperative group (blood glucose, 6.9 ± 1.0 vs 7.1 ± 0.8 mmol/L, P < .001; time in target range, 34.3% ± 12.7% vs 30.8% ± 11.5%, P < .001). Perioperative initiation of intensive insulin therapy during cardiac surgery reduces postoperative morbidity in nondiabetic patients while having a minimal effect in diabetic subjects.

26 January 2022 in Current Atherosclerosis Reports
Verified
Journal Article
Closed access
PDF file
Jan MalikJan Malik
Jan Malik
LNLudmila Nováková
Ludmila Nováková
VAValerianova A.
Valerianova A.
CEChytilova E.
Chytilova E.
LVLejsek V.
Lejsek V.
Pavel MichalekPavel Michalek
Pavel Michalek

25 September 2014 in Perfusion
Verified
Journal Article
Closed access
FMF Mlejnsky
F Mlejnsky
AKA A Klein
A A Klein
JLJarosla Lindner
Jarosla Lindner
PMP Maruna
P Maruna
JKJ Kvasnicka
J Kvasnicka
JKJ Kunstyr
J Kunstyr
Objectives: There is some controversy as to whether there is a benefit from the use of a centrifugal pump compared with a roller pump during cardiopulmonary bypass to facilitate cardiac surgery. We compared the two pumps, with the primary aim of determining any difference in the effects on inflammation after pulmonary endarterectomy surgery which required prolonged cardiopulmonary bypass and deep hypothermic circulatory arrest. Methods: Between September 2010 and July 2013, 58 elective patients undergoing pulmonary endarterectomy were included in this prospective, randomised, controlled study; 30 patients were randomly allocated to the control group, which used a roller pump, and 28 patients to the treatment group, which used a centrifugal pump. Interleukin-6, procalcitonin, C-reactive protein, thromboelastographic parameters, P-selectin, international normalised ratio, activated prothrombin time, free haemoglobin, haematocrit, red blood cell count, white blood cell count, platelet count and protein S100β were recorded during and after the procedure. We also recorded the length of intensive care unit stay, blood loss and transfusion, neurological outcomes and respiratory and renal failure. Results: There was a significant difference in the primary outcome measure: Interleukin-6 was significantly higher in the roller pump group (587±38 ng·l-1 vs. 327±37 ng·l-1; p<0.001) 24 hours after surgery, which we interpreted as an increased inflammatory response. This was confirmed by a significant rise in the procalcitonin level in the roller pump group 48 hours following surgery (0.79 (0.08-25.25) ng·ml-1 vs. 0.36 (0.02-5.83) ng·ml-1; p<0.05). There were, however, no significant differences in clinical outcome data. Conclusions: We have shown that the use of a centrifugal pump during prolonged cardiopulmonary bypass and deep hypothermic circulatory arrest is associated with a reduced inflammatory response compared to the standard roller pump. Larger multi-centre trials in this area of practice are required.

20 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JSJan Soltes
Jan Soltes
MSMichal Skribuckij
Michal Skribuckij
HŘHynek Říha
Hynek Říha
Michal LipšMichal Lipš
Michal Lipš
Pavel MichalekPavel Michalek
Pavel Michalek
MPMichal Porizka
Michal Porizka
The use of extracorporeal membrane oxygenation (ECMO) has recently increased exponentially. ECMO has become the preferred mode of organ support in refractory respiratory or circulatory failure. The fragile balance of haemostasis physiology is massively altered by the patient’s critical condition and specifically the aetiology of the underlying disease. Furthermore, an application of ECMO conveys another disturbance of haemostasis due to blood-circuit interaction and the presence of an oxygenator. The purpose of this review is to summarise current knowledge on the anticoagulation management in patients undergoing ECMO therapy. The unfractionated heparin modality with monitoring of activated partial thromboplastin tests is considered to be a gold standard for anticoagulation in this specific subgroup of intensive care patients. However, alternative modalities with other agents are comprehensively discussed. Furthermore, other ways of monitoring can represent the actual state of coagulation in a more complex fashion, such as thromboelastometric/graphic methods, and might become more frequent. In conclusion, the coagulation system of patients with ECMO is altered by multiple variables, and there is a significant lack of evidence in this area. Therefore, a highly individualised approach is the best solution today.

9 December 2018 in Physiological Research
Verified
Journal Article
Open access
ZMZ. Matloch
Z. Matloch
HKH. Kratochvílová
H. Kratochvílová
ACA. Cinkajzlová
A. Cinkajzlová
MLM. Lipš
M. Lipš
PKP. Kopecký
P. Kopecký
MHMartin Haluzík
Martin Haluzík
Omentin is a protein produced by numerous tissues including adipose tissue. Its concentrations are decreased in patients with obesity, type 2 diabetes mellitus (DM) and coronary artery disease (CAD). Experimental studies suggest that omentin may have anti-inflammatory and insulin-sensitizing properties. In the present study, we measured circulating omentin levels and its mRNA expression in epicardial and subcutaneous fat, intercostal and heart muscle before and after elective cardiac surgery in patients with CAD (CAD+, DM-, n=18), combination of CAD and DM (CAD+, DM+, n=9) or with none of these conditions (CAD-, DM-, n=11). The groups did not differ in baseline anthropometric and biochemical characteristics with the exception of higher blood glucose and HBA(1c) in CAD+, DM+ group. Baseline circulating omentin levels tended to be lower in CAD+, DM- and CAD+, DM+ groups as compared to CAD-, DM- group and cardiac surgery increased its concentration only in CAD-, DM- group. The change in serum omentin levels during surgery inversely correlated with epicardial fat thickness. While baseline omentin mRNA expression did not differ among the groups in any of the studied tissues, its increase after surgery was present only in subcutaneous fat in CAD-, DM- and CAD+, DM- groups, but not in CAD+, DM+ group. Intercostal muscle omentin mRNA expression increased after surgery only in CAD-, DM- group. In conclusion, cardiac surgery differentially affects omentin levels and subcutaneous fat and skeletal muscle mRNA expression in patients without coronary artery disease and diabetes as compared to patients with these conditions.

29 November 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
TBTomas Brozek
Tomas Brozek
JBJan Bruthans
Jan Bruthans
MPMichal Porizka
Michal Porizka
JBJan Blaha
Jan Blaha
JUJitka Ulrichova
Jitka Ulrichova
Pavel MichalekPavel Michalek
Pavel Michalek
Videolaryngoscopes may improve intubating conditions in obese patients. A total of 110 patients with a body mass index > 35 kg∙m−2 were prospectively randomized to tracheal intubation using non-channeled Glidescope Titanium or channeled King Vision videolaryngoscope. The primary outcome was the time to tracheal intubation. Secondary outcomes included: total success rate, number of attempts, the quality of visualization, peri-procedural and post-proceduralcomplications. Time to the first effective breath was shorter with the King Vision (median; 95% CI)—36; 34–39 s vs. 42; 40–50 in the Glidescope group (p = 0.007). The total success rate was higher in the Glidescope group—100% vs. 89.1% (p = 0.03). There was a higher incidence of moderate and difficult laryngoscopy in the King Vision group. No difference was recorded in first attempt success rates, total number of attempts, use of additional maneuvers, intraoperative trauma, or any significant decrease in SpO2 during intubation. No serious complications were noted and the incidence of postoperative complaints was without difference. Although tracheal intubation with King Vision showed shorter time to the first breath, total success was higher in the Glidescope group, and all but one patients where intubation failed with the KingVision were subsequently intubated with the Glidescope.