Osseointegrated prostheses are widely used following transfemoral amputation. However, this technique requires sufficient implant stability before and during the rehabilitation period to mitigate the risk of implant breakage and loosening. Hence, reliable assessment methods for the osseointegration process are essential to ensure initial and long–term implant stability. This paper researches the feasibility of a vibration analysis technique for the osseointegration (OI) process by investigating the change in the dynamic response of the residual femur with a novel implant design during a simulated OI process. The paper also proposes a concept of an energy index (the E–index), which is formulated based on the normalized magnitude. To illustrate the potential of the E–index, this paper reports on changes in the vibrational behaviors of a 133 mm long amputated artificial femur model and implant system, with epoxy adhesives applied at the interface to simulate the OI process. The results show a significant variation in the magnitude of the colormap against curing time. The study also shows that the E–index was sensitive to the interface stiffness change, especially during the early curing process. These findings highlight the feasibility of using the vibration analysis technique and the E–index to quantitatively monitor the osseointegration process for future improvement on the efficiency of human health monitoring and patient rehabilitation.
Non-woven, metal-coated, carbon veil has the potential to replace copper in radiofrequency transmission lines and micro-strip antenna elements. It is of importance to characterise the mechanical properties of these veils to implement them into antenna design. These veil materials are incorporated into a dielectric substrate made from glass-fibre reinforced plastic (GFRP). This antenna system can be integrated into a load bearing composite structure enhancing its multi-functionality and will therefore be exposed to the operational loads of the primary structure. An example of such primary structure is the wing of an unmanned aerial vehicle (UAV). This paper will report on a set of investigation detailing the effects of fatigue loading on the durability and the performance of this load bearing conformal antenna system. The fatigued antenna will be subjected to a series of cantilever loading to show the performance of the conformal antenna when the fatigue-exposed antenna is subjected to quasi-static loading that is expected during normal operation of the structure.
Glass fibre-reinforced polymer (GFRP) is a suitable substrate material for constructing a Conformal Load-Bearing Antenna Structure (CLAS). The relative permittivity of the CLAS substrate, which determines its resonant frequency, is affected by damage sustained by GFRP. This paper investigates the effects of damage (induced by mechanically loading the substrate) on the resonant response of the CLAS. Decoupling the antenna from the substrate was essential to evaluate the CLAS’s true response to the induced damage. This paper details a systematic investigation examining how the frequency response of a “pristine” antenna and a surface-mounted antenna respond to a substrate subjected to quasi-statically induced mechanical damage and cyclic fatigue loading. The results demonstrate that the resonant frequency of the CLAS varies as a function of the substrate’s mechanical damage. The prepared CLAS is tolerant to a certain degree of mechanical loading and related damage with its resonant frequency remaining within an acceptable bandwidth.
Investigation of vibrational assessment on osseointegration process with a novel implant design Shouxun Lu, Benjamin Steven Vien, Matthias Russ, Mark Fitzge
Osseointegration implant has attracted significant attention as an alternative treatment for transfemoral amputees. It has been shown to improve patients’ sitting and walking comfort and control of the artificial limb, compared to the conventional socket device. However, the patients treated with osseointegration implants require a long rehabilitation period to establish sufficient femur–implant connection, allowing the full body weight on the prosthesis stem. Hence, a robust assessment method on the osseointegration process is essential to shorten the rehabilitation period and identify the degree of osseointegration prior to the connection of an artificial limb. This paper investigates the capability of a vibration-related index (E-index) on detecting the degree of simulated osseointegration process with three lengths of the residual femur (152, 190 and 228 mm). The adhesive epoxy with a setting time of 5 min was applied at the femur–implant interface to represent the stiffness change during the osseointegration process. The cross-spectrum and colormap of the normalised magnitude demonstrated significant changes during the cure time, showing that application of these plots could improve the accuracy of the currently available diagnostic techniques. Furthermore, the E-index exhibited a clear trend with a noticeable average increase of 53% against the cure time for all three residual length conditions. These findings highlight that the E-index can be employed as a quantitative justification to assess the degree of osseointegration process without selecting and tracing the resonant frequency based on the geometry of the residual femur.