Wingkong Chiu

Prof. Wingkong Chiu

Department of Mechanical and Aerospace Engineering, Monash University, Room G27A, 17 College Walk (Building 31), Clayton Campus, Wellington Road, Clayton, Victoria 3800, Australia
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
LWLeslie Wong
Leslie Wong
RDRavin Deo
Ravin Deo
SRSuranji Rathnayaka
Suranji Rathnayaka
BSBenjamin Shannon
Benjamin Shannon
IZIvan Zhang
Ivan Zhang
HWHera Widyastuti
Hera Widyastuti
Leakage is undesirable in water distribution networks, as leaky pipes are financially costly both to water utilities and consumers. The ability to detect, locate, and quantify leaks can significantly improve the service delivered. Optical fibre sensors (OFS) have previously demonstrated their capabilities in performing real-time and continuous monitoring of pipe strength leak detection. However, the challenge remains due to the high labour cost and time-consuming process for the installation of optical fibre sensors to existing buried pipelines. The aim of this paper is to evaluate the feasibility of a submersible optical fibre-based pressure sensor that can be deployed without rigid bonding to the pipeline. This paper presents a set of experiments conducted using the proposed sensing strategy for leak detection. The calibrated optical fibre device was used to monitor the internal water pressure in a pipe with simultaneous verification from a pressure gauge. Two different pressure-based leak detection methods were explored. These leak detection methods were based on hydrostatic and pressure transient responses of the optical fibre pressure sensor. Experimental results aided in evaluating the functionality, reliability, and robustness of the submersible optical fibre pressure sensor.

14 May 2016 in Materials
Verified
Journal Article
Open access
PDF file
LWLeslie Wong
Leslie Wong
NCNabil Muntaser Chowdhury
Nabil Muntaser Chowdhury
JWJohn Wang
John Wang
Wingkong ChiuWingkong Chiu
Wingkong Chiu
JKJayantha Kodikara
Jayantha Kodikara
Over the past few decades, there has been a considerable interest in the use of distributed optical fibre sensors (DOFS) for structural health monitoring of composite structures. In aerospace-related work, health monitoring of the adhesive joints of composites has become more significant, as they can suffer from cracking and delamination, which can have a significant impact on the integrity of the joint. In this paper, a swept-wavelength interferometry (SWI) based DOFS technique is used to monitor the fatigue in a flush step lap joint composite structure. The presented results will show the potential application of distributed optical fibre sensor for damage detection, as well as monitoring the fatigue crack growth along the bondline of a step lap joint composite structure. The results confirmed that a distributed optical fibre sensor is able to enhance the detection of localised damage in a structure.

28 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
WOWern Hann Ong
Wern Hann Ong
Wingkong ChiuWingkong Chiu
Wingkong Chiu
TKThomas Kuen
Thomas Kuen
JKJayantha Kodikara
Jayantha Kodikara
Floating covers used in waste water treatment plants are one of the many structures formed with membrane materials. These structures are usually large and can spread over an area measuring 470 m × 170 m. The aim of this paper is to describe recent work to develop an innovative and effective approach for structural health monitoring (SHM) of such large membrane-like infrastructure. This paper will propose a potentially cost-effective non-contact approach for full-field strain and stress mapping using an unmanned aerial vehicle (UAV) mounted with a digital camera and a global positioning system (GPS) tracker. The aim is to use the images acquired by the UAV to define the geometry of the floating cover using photogrammetry. In this manner, any changes in the geometry of the floating cover due to forces acting beneath resulting from its deployment and usage can be determined. The time-scale for these changes is in terms of weeks and months. The change in the geometry can be implemented as input conditions to a finite element model (FEM) for stress prediction. This will facilitate the determination of the state of distress of the floating cover. This paper investigates the possibility of using data recorded from a UAV to predict the strain level and assess the health of such structures. An investigation was first conducted on a laboratory sized membrane structure instrumented with strain gauges for comparison against strains, which were computed from 3D scans of the membrane geometry. Upon validating the technique in the laboratory, it was applied to a more realistic scenario: an outdoor test membrane structure and capable UAV were constructed to see if the shape of the membrane could be computed. The membrane displacements were then used to calculate the membrane stress and strain, state demonstrating a new way to perform structural health monitoring on membrane structures.

12 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NZNaizhong Zhang
Naizhong Zhang
CDClaire Davis
Claire Davis
Wingkong ChiuWingkong Chiu
Wingkong Chiu
TBTommy Boilard
Tommy Boilard
MBMartin Bernier
Martin Bernier
Although fibre Bragg gratings (FBGs) offer obvious potential for use in high-density, high-strain sensing applications, the adoption of this technology in the historically conservative aerospace industry has been slow. There are several contributing factors, one of which is variability in the reported performance of these sensors in harsh and fatigue prone environments. This paper reports on a comparative evaluation of the fatigue performance of FBG sensors written according to the same specifications using three different grating manufacturing processes: sensors written in stripped and re-coated fibres, sensors written during the fibre draw process and sensors written through fibre coating. Fatigue cycling of the fibres is provided by a customized electro-dynamically actuated loading assembly designed to provide high frequency and amplitude loading. Pre- and post-fatigue microscopic analysis and high-resolution transmission and reflection spectra scanning are conducted to investigate the fatigue performance of FBGs, the failure regions of fibres as well as any fatigue-related effects on the spectral profiles. It was found that because of the unique fabrication method, the sensors written through the fibre coating, also known as trans-jacket FBGs, show better fatigue performance than stripped and re-coated FBGs with greater control possible to tailor the optical reflection properties compared to gratings written in the draw tower. This emerging method for inscription of Type I gratings opens up the potential for mass production of higher reflectivity, apodised sensors with dense or complex array architectures which can be adopted as sensors for harsh environments such as in defence and aerospace industries.

22 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
BVBenjamin Vien
Benjamin Vien
Wingkong ChiuWingkong Chiu
Wingkong Chiu
MRMatthias Russ
Matthias Russ
MFMark Fitzgerald
Mark Fitzgerald
Quantitative and reliable monitoring of osseointegration will help further evaluate the integrity of the orthopaedic construct to promote novel prosthesis design and allow early mobilisation. Quantitative assessment of the degree or the lack of osseointegration is important for the clinical management with the introduction of prosthetic implants to amputees. Acousto-ultrasonic wave propagation has been used in structural health monitoring as well as human health monitoring but so far has not extended to osseointegrated implants or prostheses. This paper presents an ultrasonic guided wave approach to assess the osseointegration of a novel implant. This study explores the potential of integrating structural health monitoring concepts into a new osseointegrated implant. The aim is to demonstrate the extension of acousto-ultrasonic techniques, which have been widely reported for the structural health monitoring of engineering structures, to assess the state of osseointegration of a bone and implant. To illustrate this potential, this paper will report on the experimental findings which investigated the unification of an aluminium implant and bone-like geometry surrogate. The core of the test specimen is filled with silicone and wrapped with plasticine to simulate the highly damped cancellous bone and soft tissue, respectively. To simulate the osseointegration process, a 2-h adhesive epoxy is used to bond the surrogate implant and a bone-like structure. A series of piezoelectric elements are bonded onto the surrogate implant to serve as actuators and sensors. The actuating piezoelectric element on an extramedullary strut is excited with a 1 MHz pulse signal. The reception of the ultrasonic wave by the sensing elements located on the adjacent and furthest struts is used to assess the integration of this implant to the parent bone structure. The study shows an Osseointegration Index can be formulated by using engineering and acousto-ultrasonic methods to measure the unification of a bone and implant. This also highlights a potential quantitative evaluation technique regardless of bone-implant geometry and soft tissue damping.

19 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Wingkong ChiuWingkong Chiu
Wingkong Chiu
BVBenjamin Vien
Benjamin Vien
MRMatthias Russ
Matthias Russ
MFMark Fitzgerald
Mark Fitzgerald
The lack of a quantitative method to adequately assess fractured bone healing that has undergone fixation limits prognostic capabilities on patients’ optimal return to work. This paper addresses the use of vibrational analysis to monitor the state of healing of a plate-screw fixated femur and supplement the current clinical radiographic assessment. This experimental study involves an osteotomised composite femur specimen enclosed by modelling clay to simulate the damping effect of overlying soft tissues. Epoxy adhesives are applied to the fractured region and to simulate the healing process. With the instrumentation described, the cross-spectrum and coherence are obtained and analysed in the frequency domain over a period of time. The results suggest that it is crucial to analyse the cross-spectrum and proposed healing index to quantitatively assess the stages of healing. The results also show that the mass loading effect due to modelling clay did not influence the proposed healing assessment technique. The findings indicate a potential non-intrusive technique to evaluate the healing of fractured femur by utilising the vibrational responses.