Xinlong Huang

Dr. Xinlong Huang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
XDXianshan Dong
Xianshan Dong
XHXinlong Huang
Xinlong Huang
GDG Z Du gz du
G Z Du gz du
QHQinwen Huang
Qinwen Huang
YHYixiong Huang
Yixiong Huang
PLPing Lai
Ping Lai
For linear accelerometers, calibration with a precision centrifuge is a key technology, and the input acceleration imposed on the accelerometer should be accurately obtained in the calibration. However, there are often errors in the installation of sample that make the calibration inaccurate. To solve installation errors and obtain the input acceleration in the calibration of the accelerometer, a calibration method based on the rotation principle using a double turntable centrifuge is proposed in this work. The key operation is that the sub-turntable is rotated to make the input axis of the accelerometer perpendicular to the direction of the centripetal acceleration vector. Models of installation errors of angle and radius were built. Based on these models, the static radius and input acceleration can be obtained accurately, and the calibration of the scale factor, nonlinearity and asymmetry can be implemented. Using this method, measurements of the MEMS accelerometer with a range of ±30 g were carried out. The results show that the discrepancy of performance obtained from different installation positions was smaller than 100 ppm after calibrating the input acceleration. Moreover, the results using this method were consistent with those using the back-calculation method. These results demonstrate that the effectiveness of our proposed method was confirmed. This method can measure the static radius directly eliminating the installation errors of angle and radius, and it simplifies the accelerometer calibration procedure.

11 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
GDG Z Du gz du
G Z Du gz du
XDXianshan Dong
Xianshan Dong
XHXinlong Huang
Xinlong Huang
WSWei Su
Wei Su
PZPeng Zhang
Peng Zhang
Vacuum packaging is used extensively in MEMS sensors for improving performance. However, the vacuum in the MEMS chamber gradually degenerates over time, which adversely affects the long-term performance of the MEMS sensor. A mathematical model for vacuum degradation is presented in this article for evaluating the degradation of vacuum packaged MEMS sensors, and a temperature-accelerated test of MEMS gyroscope with different vacuums is performed. A mathematical degradation model is developed to fit the parameters of the degradation of Q-factor over time at three different temperatures. The results indicate that the outgassing rate at 85 °C is the highest, which is 0.0531 cm2/s; the outgassing rate at 105 °C is the lowest, which is 0.0109 cm2/s; and the outgassing rate at 125 °C is in the middle, which is 0.0373 cm2/s. Due to the different mechanisms by which gas was released, the rate of degradation did not follow this rule. It will also be possible to predict the long-term reliability of vacuum packaged MEMS sensors at room temperature based on this model.

12 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
XHXinlong Huang
Xinlong Huang
XDXianshan Dong
Xianshan Dong
GDG Z Du gz du
G Z Du gz du
YHYouwang Hu
Youwang Hu
During long-term use, MEMS accelerometers will experience degradation, such as bias and scale factor changes. Bias of MEMS capacitive accelerometers usually comes from the mismatch of parasitic capacitance and sensitive capacitance. This paper focuses on the mismatch of sensitive capacitance and analyzes the mechanism of long-term degradation of MEMS accelerometers. Firstly, the effect of sensitive capacitance mismatch on the performance of a MEMS accelerometer was investigated. Secondly, a method of measuring the mismatch of sensitive capacitance was proposed, and the validation experiment shows that the accuracy of this measurement can be less than 1.10×10−5 of the sensitive capacitance. For the samples in this experiment, the measurement error of this method can be less than 0.36 fF. Finally, a high-temperature acceleration experiment was performed. The mismatch of the sensitive capacitance during the experiment was monitored based on the proposed method, and the experimental results are analyzed. The experimental result demonstrates that the mismatch of sensitive capacitance varies linearly with time. The change rates of sensitive capacitance mismatch for the two samples are 2.95×10−7 C0/h and 2.66×10−7 C0/h in the high-temperature acceleration experiment at 145 °C, respectively. The change in sensitive capacitance mismatch seems small, but it is not to be ignored during long-term use. The rate of change is similar for the same batch of samples. This could imply that the adverse effects due to the mismatch of sensitive capacitance changes can be reduced by compensating for this variation.