Ping Lai

Ping Lai


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2020 in Eksploatacja i Niezawodność – Maintenance and Reliability
Verified
Journal Article
Closed access
YCYuan Chen
Yuan Chen
WSWei Su
Wei Su
Hong-Zhong HuangHong-Zhong Huang
Hong-Zhong Huang
PLPing Lai
Ping Lai
XLXiao-Ling Lin
Xiao-Ling Lin
SCSi Chen
Si Chen
Through silicon via (TSV) has become one of the key emerging trends of three-dimensional (3D) packages, as it can realize vertically interconnect between stacked-dies. Due to large mismatch in thermal expansion coefficients (CTE) between the copper via and the silicon, significant mechanical stresses are induced at the interfaces when TSV structure is subjected to thermal stresses, which would greatly affect the reliability and electrical performance of TSV 3D device. In this paper, the relationship between the state of stresses and failure of TSV had been explored by combining finite element model simulation (FEM) and failure physical analysis. The position of the maximum stress of the TSV structure was obtained by FEM analysis. The relationship of stress and displacement change with temperature was also studied. And a thermal cycling experiment was conducted to validate the simulation results. Physical failure analysis after thermal cycling experiment was used to verify the degradation mechanism predicted by thermo-mechanical simulation.

30 December 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
XDXianshan Dong
Xianshan Dong
XHXinlong Huang
Xinlong Huang
GDG Z Du gz du
G Z Du gz du
QHQinwen Huang
Qinwen Huang
YHYixiong Huang
Yixiong Huang
PLPing Lai
Ping Lai
For linear accelerometers, calibration with a precision centrifuge is a key technology, and the input acceleration imposed on the accelerometer should be accurately obtained in the calibration. However, there are often errors in the installation of sample that make the calibration inaccurate. To solve installation errors and obtain the input acceleration in the calibration of the accelerometer, a calibration method based on the rotation principle using a double turntable centrifuge is proposed in this work. The key operation is that the sub-turntable is rotated to make the input axis of the accelerometer perpendicular to the direction of the centripetal acceleration vector. Models of installation errors of angle and radius were built. Based on these models, the static radius and input acceleration can be obtained accurately, and the calibration of the scale factor, nonlinearity and asymmetry can be implemented. Using this method, measurements of the MEMS accelerometer with a range of ±30 g were carried out. The results show that the discrepancy of performance obtained from different installation positions was smaller than 100 ppm after calibrating the input acceleration. Moreover, the results using this method were consistent with those using the back-calculation method. These results demonstrate that the effectiveness of our proposed method was confirmed. This method can measure the static radius directly eliminating the installation errors of angle and radius, and it simplifies the accelerometer calibration procedure.

22 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
XDXianshan Dong
Xianshan Dong
YHYun Huang
Yun Huang
PLPing Lai
Ping Lai
QHQinwen Huang
Qinwen Huang
WSWei Su
Wei Su
WXWEI XU
WEI XU
In a MEMS capacitive accelerometer, there is an offset due to mechanical and electrical factors, and the offset would deteriorate the performance of the accelerometer. Reducing the offset from mechanism would benefit the improvement in performance. Yet, the compositions of the offset are complex and mix together, so it is difficult to decompose the offset to provide guidance for the reduction. In this work, a decomposition method of offset in a MEMS capacitive accelerometer was proposed. The compositions of the offset were first analyzed quantitatively, and methods of measuring key parameters were developed. Based on our proposed decomposition method, the experiment of offset decomposition with a closed-loop MEMS capacitive accelerometer was carried out. The results showed that the offset successfully decomposed, and the major source was from the fabricated gap mismatch in the MEMS sensor. This work provides a new way for analyzing the offset in a MEMS capacitive accelerometer, and it is helpful for purposefully taking steps to reduce the offset and improve accelerometer performance.

2 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YCYuan Chen
Yuan Chen
PLPing Lai
Ping Lai
Hong-Zhong HuangHong-Zhong Huang
Hong-Zhong Huang
PZPeng Zhang
Peng Zhang
XLXiaoling Lin
Xiaoling Lin
With the development of 3D integrated packaging technology, failure analysis is facing more and more challenges. Defect localization in a 3D package is a key step of failure analysis. The complex structure and materials of 3D package devices demand non-destructive defect localization technology for full packages. Magnetic field imaging and three-dimensional X-ray technology are not affected by package material or form. They are effective methods to realize defect localization on 3D packages. In this paper, magnetic field imaging and high-resolution three-dimensional X-ray microscopy were used to localize the open defect in a 3D package with a TSV daisy chain. A two-probe RF method in magnetic field imaging was performed to resolve isolation of the defect difficulties resulting from many different branches of TSV daisy chains. Additionally, a linear decay method was used to target sub-micron resolution at a long working distance. Multiple partition scans from a high-resolution 3D X-ray microscopy with a two-stage magnification structure were used to achieve sub-micron resolution. The open location identified by magnetic field imaging was consistent with that identified by a three-dimensional X-ray microscope. The opening was located on the top metal in the proximity of the fifth via. Physical failure analysis revealed the presence of a crack in the top metal at the opening location.