Chi Chiu Chan

Chi Chiu Chan


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2019 in Materials
Verified
Journal Article
Open access
PDF file
ZGZidan Gong
Zidan Gong
ZXZiyang Xiang
Ziyang Xiang
XOXia OUYANG
Xia OUYANG
JZJun Zhang
Jun Zhang
NLNewman Lau
Newman Lau
CCChi Chiu Chan
Chi Chiu Chan
Emerging smart textiles have enriched a variety of wearable technologies, including fiber optic technology. Optic fibers are widely applied in communication, sensing, and healthcare, and smart textiles enable fiber optic technology to be worn close to soft and curved human body parts for personalized functions. This review briefly introduces wearable fiber optic applications with various functions, including fashion and esthetics, vital signal monitoring, and disease treatment. The main working principles of side emission, wavelength modulation, and intensity modulation are summarized. In addition, textile fabrication techniques, including weaving and knitting, are discussed and illustrated as combination methods of embedding fiber optic technology into textile fabric. In conclusion, the combination of optical fibers and textiles has drawn considerable interest and developed rapidly. This work provides an overview of textile-based wearable fiber optic technology and discusses potential textile fabrication techniques for further improvement of wearable fiber optic applications.

28 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZSZhao Shumi
Zhao Shumi
JLJianxun Liu
Jianxun Liu
ZGZidan Gong
Zidan Gong
YLYisong Lei
Yisong Lei
XOXia OUYANG
Xia OUYANG
SRShuangchen Ruan
Shuangchen Ruan
Secondary injuries are common during upper limb rehabilitation training because of uncontrollable physical force and overexciting activities, and long-time training may cause fatigue and reduce the training effect. This study proposes a wearable monitoring device for upper limb rehabilitation by integrating electrocardiogram and electromyogram (ECG/EMG) sensors and using data acquisition boards to obtain accurate signals during robotic glove assisting training. The collected ECG/EMG signals were filtered, amplified, digitized, and then transmitted to a remote receiver (smart phone or laptop) via a low-energy Bluetooth module. A software platform was developed for data analysis to visualize ECG/EMG information, and integrated into the robotic glove control module. In the training progress, various hand activities (i.e., hand closing, forearm pronation, finger flexion, and wrist extension) were monitored by the EMG sensor, and the changes in the physiological status of people (from excited to fatigue) were monitored by the ECG sensor. The functionality and feasibility of the developed physiological monitoring system was demonstrated by the assisting robotic glove with an adaptive strategy for upper limb rehabilitation training improvement. The feasible results provided a novel technique to monitor individual ECG and EMG information holistically and practically, and a technical reference to improve upper limb rehabilitation according to specific treatment conditions and the users’ demands. On the basis of this wearable monitoring system prototype for upper limb rehabilitation, many ECG-/EMG-based mobile healthcare applications could be built avoiding some complicated implementation issues such as sensors management and feature extraction.

1 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ZGZidan Gong
Zidan Gong
YLYisong Lei
Yisong Lei
ZWZiwen Wang
Ziwen Wang
JZJie Zhang
Jie Zhang
ZSZeji Sun
Zeji Sun
XOXia OUYANG
Xia OUYANG
Copper ion is closely associated with the ecosystem and human health, and even a little excessive dose in drinking water may result in a range of health problems. However, it remains challenging to produce a highly sensitive, reliable, cost-effective and electromagnetic-interference interference-immune device to detect Cu2+ ion in drinking water. In this paper, a taper-in-taper fiber sensor was fabricated with high sensitivity by mode-mode interference and deposited polyelectrolyte layers for Cu2+ detection. We propose a new structure which forms a secondary taper in the middle of the single-mode fiber through two-arc discharge. Experimental results show that the newly developed fiber sensor possesses a sensitivity of 2741 nm/RIU in refractive index (RI), exhibits 3.7 times sensitivity enhancement when compared with traditional tapered fiber sensors. To apply this sensor in copper ions detection, the results present that when the concentration of Cu2+ is 0–0.1 mM, the sensitivity could reach 78.03 nm/mM. The taper-in-taper fiber sensor exhibits high sensitivity with good stability and mechanical strength which has great potential to be applied in the detection of low Cu2+ ions in some specific environments such as drinking water.

10 December 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
ZXZiyang Xiang
Ziyang Xiang
LWLiuwei Wan
Liuwei Wan
ZGZidan Gong
Zidan Gong
ZZZhuxin Zhou
Zhuxin Zhou
ZMZhengyi Ma
Zhengyi Ma
CCChi Chiu Chan
Chi Chiu Chan
Wearable sensing technologies have been developed rapidly in the last decades for physiological and biomechanical signal monitoring. Much attention has been paid to functions of wearable applications, but comfort parameters have been overlooked. This research presents a developed fabric temperature sensor by adopting fiber Bragg grating (FBG) sensors and processing via a textile platform. This FBG-based quasi-distributed sensing system demonstrated a sensitivity of 10.61 ± 0.08 pm/°C with high stability in various temperature environments. No obvious wavelength shift occurred under the curvatures varying from 0 to 50.48 m−1 and in different integration methods with textiles. The temperature distribution monitored by the developed textile sensor in a complex environment with multiple heat sources was deduced using MATLAB to present a real-time dynamic temperature distribution in the wearing environment. This novel fabric temperature sensor shows high sensitivity, stability, and usability with comfort textile properties that are of great potential in wearable applications.

30 January 2021 in Photonics
Verified
Journal Article
Open access
PDF file
HTHe tiefeng
He tiefeng
GPGuobing Pan
Guobing Pan
LZLibin Zhang
Libin Zhang
FXFang XU
Fang XU
CYCan Yang
Can Yang
GZGuoliang Zheng
Guoliang Zheng
The powersphere is a device used for maximizing the conversion of light in wireless energy transmission via laser. It is a spherical structure made up of thousands of photovoltaic cells. Due to the large dimensions and existence of many holes in the spherical surface, there are some drawbacks in machining, such as limited movement space of the machines, long cycle, low precision, and high cost. In this context, with a powersphere irradiated by the laser as the model, the principle of powersphere is deduced theoretically. It is proven that the illuminance value at any position on the inner wall of the powersphere is equal, and the calculation formula of this value is derived. Based on this theory and the comparative analysis of processing methods and the results of processing experiments, the structure of the powersphere is designed. The experimental processing of the powersphere is carried out by selecting the welding method. Finally, two hemispherical powersphere frames are processed, which are connected by screws to form a ball frame for the installation of photovoltaic cells. The results show that the improved design and fabricating method can process the powersphere quickly, accurately, and economically. A comparative experiment of powersphere and photovoltaic panel was carried out. The experimental results show that the powersphere has the function of light uniformity and repeated use of laser. So, the designed and processed powersphere is consistent with the theoretical analysis.