VIVIANNE FREITAS

Prof. VIVIANNE FREITAS

University of Toronto, Toronto, Ontario, Canada
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in Radiology
Verified
Journal Article
Closed access
HHHeba Hussein
Heba Hussein
EAEngy Abbas
Engy Abbas
SKSareh Keshavarzi
Sareh Keshavarzi
RFRouhi Fazelzad
Rouhi Fazelzad
KBKarina Bukhanov
Karina Bukhanov
VFVIVIANNE FREITAS
VIVIANNE FREITAS
Background The best supplemental breast cancer screening modality in women at average risk or intermediate risk for breast cancer with dense breast and negative mammogram remains to be determined. Purpose To conduct systematic review and meta-analysis comparing clinical outcomes of the most common available supplemental screening modalities in women at average risk or intermediate risk for breast cancer in patients with dense breasts and mammography with negative findings. Materials and Methods A comprehensive search was conducted until March 12, 2020, in Medline, Epub Ahead of Print and In-Process and Other Non-Indexed Citations; Embase Classic and Embase; Cochrane Central Register of Controlled Trials; and Cochrane Database of Systematic Reviews, for Randomized Controlled Trials and Prospective Observational Studies. Incremental cancer detection rate (CDR); positive predictive value of recall (PPV1); positive predictive value of biopsies performed (PPV3); and interval CDRs of supplemental imaging modalities, digital breast tomosynthesis, handheld US, automated breast US, and MRI in non-high-risk patients with dense breasts and mammography negative for cancer were reviewed. Data metrics and risk of bias were assessed. Random-effects meta-analysis and two-sided metaregression analyses comparing each imaging modality metrics were performed (PROSPERO; CRD42018080402). Results Twenty-two studies reporting 261 233 screened patients were included. Of 132 166 screened patients with dense breast and mammography negative for cancer who met inclusion criteria, a total of 541 cancers missed at mammography were detected with these supplemental modalities. Metaregression models showed that MRI was superior to other supplemental modalities in CDR (incremental CDR, 1.52 per 1000 screenings; 95% CI: 0.74, 2.33; P < .001), including invasive CDR (invasive CDR, 1.31 per 1000 screenings; 95% CI: 0.57, 2.06; P < .001), and in situ disease (rate of ductal carcinoma in situ, 1.91 per 1000 screenings; 95% CI: 0.10, 3.72; P < .04). No differences in PPV1 and PPV3 were identified. The limited number of studies prevented assessment of interval cancer metrics. Excluding MRI, no statistically significant difference in any metrics were identified among the remaining imaging modalities. Conclusion The pooled data showed that MRI was the best supplemental imaging modality in women at average risk or intermediate risk for breast cancer with dense breasts and mammography negative for cancer. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Hooley and Butler in this issue.

30 January 2020 in European Radiology
Verified
Journal Article
Closed access
PDF file
YAYoav Amitai
Yoav Amitai
Anabel M ScaraneloAnabel M Scaranelo
Anabel M Scaranelo
TMTehillah S. Menes
Tehillah S. Menes
RFRachel Fleming
Rachel Fleming
SKSupriya Kulkarni
Supriya Kulkarni
VFVIVIANNE FREITAS
VIVIANNE FREITAS

1 August 2022 in Radiology
Verified
Journal Article
Closed access
VFVIVIANNE FREITAS
VIVIANNE FREITAS
XLXuan Li
Xuan Li
YAYoav Amitai
Yoav Amitai
FAFrederick Au
Frederick Au
SKSupriya Kulkarni
Supriya Kulkarni
TSTimo Siepmann
Timo Siepmann
In patients with newly diagnosed breast cancer, preoperative breast MRI depicted contralateral synchronous disease and was associated with improved overall survival. Background The diagnostic value of screening the contralateral breast with MRI in patients with newly diagnosed breast cancer is poorly understood. Purpose To assess the impact of MRI for screening...

6 July 2021 in Canadian Association of Radiologists Journal
Verified
Journal Article
Open access
PDF file
SKSupriya Kulkarni
Supriya Kulkarni
VFVIVIANNE FREITAS
VIVIANNE FREITAS
DMDerek Muradali
Derek Muradali
Digital breast tomosynthesis (DBT) is gradually being implemented in routine clinical breast imaging practice. The technique of image acquisition reduces the confounding effect of overlapping breast tissue, which substantially affects cancer detection, abnormal recall, and interval cancer rates in a screening/ surveillance setting. In a diagnostic setting, tomosynthesis also allows for improved lesion localization and characterization over conventional imaging, which potentially improves the accuracy and improved workflow efficiency. To optimize the utility of tomosynthesis, imagers should be aware of the pertinent aspects of image acquisition as it relates to interpretation, the appearance of benign and malignant pathologies, and sources of possible misinterpretation. This article aims to provide a practical knowledge base of DBT and demonstrate its potential benefits when incorporated into routine clinical practice.

1 March 2024 in Radiology: Imaging Cancer
Verified
Journal Article
Closed access
VFVIVIANNE FREITAS
VIVIANNE FREITAS
XLXuan Li
Xuan Li
Anabel M ScaraneloAnabel M Scaranelo
Anabel M Scaranelo
FAFrederick Au
Frederick Au
SKSupriya Kulkarni
Supriya Kulkarni
ARAlla Reznik
Alla Reznik
Purpose To investigate the feasibility of low-dose positron emission mammography (PEM) concurrently to MRI to identify breast cancer and determine its local extent. Materials and Methods In this research ethics board-approved prospective study, participants newly diagnosed with breast cancer with concurrent breast MRI acquisitions were assigned independently of breast density, tumor size, and histopathologic cancer subtype to undergo low-dose PEM with up to 185 MBq of fluorine 18-labeled fluorodeoxyglucose (18F-FDG). Two breast radiologists, unaware of the cancer location, reviewed PEM images taken 1 and 4 hours following 18F-FDG injection. Findings were correlated with histopathologic results. Detection accuracy and participant details were examined using logistic regression and summary statistics, and a comparative analysis assessed the efficacy of PEM and MRI additional lesions detection (ClinicalTrials.gov: NCT03520218). Results Twenty-five female participants (median age, 52 years; range, 32-85 years) comprised the cohort. Twenty-four of 25 (96%) cancers (19 invasive cancers and five in situ diseases) were identified with PEM from 100 sets of bilateral images, showcasing comparable performance even after 3 hours of radiotracer uptake. The median invasive cancer size was 31 mm (range, 10-120). Three additional in situ grade 2 lesions were missed at PEM. While not significant, PEM detected fewer false-positive additional lesions compared with MRI (one of six [16%] vs eight of 13 [62%]; P = .14). Conclusion This study suggests the feasibility of a low-dose PEM system in helping to detect invasive breast cancer. Though large-scale clinical trials are essential to confirm these preliminary results, this study underscores the potential of this low-dose PEM system as a promising imaging tool in breast cancer diagnosis. ClinicalTrials.gov registration no. NCT03520218 Keywords: Positron Emission Digital Mammography, Invasive Breast Cancer, Oncology, MRI Supplemental material is available for this article. © RSNA, 2024 See also commentary by Barreto and Rapelyea in this issue.

21 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JSJustin Stiles
Justin Stiles
BBBrandon Baldassi
Brandon Baldassi
OBOleksandr Bubon
Oleksandr Bubon
HPHarutyun Poladyan
Harutyun Poladyan
VFVIVIANNE FREITAS
VIVIANNE FREITAS
ARAlla Reznik
Alla Reznik
The aim of this study is to evaluate the performance of the Radialis organ-targeted positron emission tomography (PET) Camera with standardized tests and through assessment of clinical-imaging results. Sensitivity, count-rate performance, and spatial resolution were evaluated according to the National Electrical Manufacturers Association (NEMA) NU-4 standards, with necessary modifications to accommodate the planar detector design. The detectability of small objects was shown with micro hotspot phantom images. The clinical performance of the camera was also demonstrated through breast cancer images acquired with varying injected doses of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (18F-FDG) and qualitatively compared with sample digital full-field mammography, magnetic resonance imaging (MRI), and whole-body (WB) PET images. Micro hotspot phantom sources were visualized down to 1.35 mm-diameter rods. Spatial resolution was calculated to be 2.3 ± 0.1 mm for the in-plane resolution and 6.8 ± 0.1 mm for the cross-plane resolution using maximum likelihood expectation maximization (MLEM) reconstruction. The system peak noise equivalent count rate was 17.8 kcps at a 18F-FDG concentration of 10.5 kBq/mL. System scatter fraction was 24%. The overall efficiency at the peak noise equivalent count rate was 5400 cps/MBq. The maximum axial sensitivity achieved was 3.5%, with an average system sensitivity of 2.4%. Selected results from clinical trials demonstrate capability of imaging lesions at the chest wall and identifying false-negative X-ray findings and false-positive MRI findings, even at up to a 10-fold dose reduction in comparison with standard 18F-FDG doses (i.e., at 37 MBq or 1 mCi). The evaluation of the organ-targeted Radialis PET Camera indicates that it is a promising technology for high-image-quality, low-dose PET imaging. High-efficiency radiotracer detection also opens an opportunity to reduce administered doses of radiopharmaceuticals and, therefore, patient exposure to radiation.