Michal R Tomaszewski

Dr. Michal R Tomaszewski

Translational Imaging Department, Merck & Co, West Point, PA, USA
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2016 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
FBFrederic M. Brochu
Frederic M. Brochu
JBJoanna Brunker
Joanna Brunker
JJJames Joseph
James Joseph
MTMichal R Tomaszewski
Michal R Tomaszewski
SMStefan Morscher
Stefan Morscher
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Optoacoustic tomography is a fast developing imaging modality, combining the high contrast available from optical excitation of tissue with the high resolution and penetration depth of ultrasound detection. Light is subject to both absorption and scattering when traveling through tissue; adequate knowledge of tissue optical properties and hence the spatial fluence distribution is required to create an optoacoustic image that is directly proportional to chromophore concentrations at all depths. Using data from a commercial multispectral optoacoustic tomography (MSOT) system, we implemented an iterative optimization for fluence correction based on a finite-element implementation of the delta-Eddington approximation to the Radiative Transfer Equation (RTE). We demonstrate a linear relationship between the image intensity and absorption coefficients across multiple wavelengths and depths in phantoms. We also demonstrate improved feature visibility and spectral recovery at depth in phantoms and with in vivo measurements, suggesting our approach could in the future enable quantitative extraction of tissue absorption coefficients in biological tissue.

1 January 2017 in Theranostics
Verified
Journal Article
Open access
MTMichal R Tomaszewski
Michal R Tomaszewski
Isabel Quiros-GonzalezIsabel Quiros-Gonzalez
Isabel Quiros-Gonzalez
JOJames Pb O'Connor
James Pb O'Connor
OAOshaani Abeyakoon
Oshaani Abeyakoon
GPGeoff Parker
Geoff Parker
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Poor oxygenation of solid tumours has been linked with resistance to chemo- and radio-therapy and poor patient outcomes, hence non-invasive imaging of oxygen supply and demand in tumours could improve disease staging and therapeutic monitoring. Optoacoustic tomography (OT) is an emerging clinical imaging modality that provides static images of endogenous haemoglobin concentration and oxygenation. Here, we demonstrate oxygen enhanced (OE)-OT, exploiting an oxygen gas challenge to visualise the spatiotemporal heterogeneity of tumour vascular function. We show that tracking oxygenation dynamics using OE-OT reveals significant differences between two prostate cancer models in nude mice with markedly different vascular function (PC3 & LNCaP), which appear identical in static OT. LNCaP tumours showed a spatially heterogeneous response within and between tumours, with a substantial but slow response to the gas challenge, aligned with ex vivo analysis, which revealed a generally perfused and viable tumour with marked areas of haemorrhage. PC3 tumours had a lower fraction of responding pixels compared to LNCaP with a high disparity between rim and core response. While the PC3 core showed little or no dynamic response, the rim showed a rapid change, consistent with our ex vivo findings of hypoxic and necrotic core tissue surrounded by a rim of mature and perfused vasculature. OE-OT metrics are shown to be highly repeatable and correlate directly on a per-tumour basis to tumour vessel function assessed ex vivo. OE-OT provides a non-invasive approach to reveal the complex dynamics of tumour vessel perfusion, permeability and vasoactivity in real time. Our findings indicate that OE-OT holds potential for application in prostate cancer patients, to improve delineation of aggressive and indolent disease as well as in patient stratification for chemo- and radio-therapy.

26 January 2017 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
JJJames Joseph
James Joseph
MTMichal R Tomaszewski
Michal R Tomaszewski
Isabel Quiros-GonzalezIsabel Quiros-Gonzalez
Isabel Quiros-Gonzalez
JWJudith Weber
Judith Weber
JBJoanna Brunker
Joanna Brunker
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Optoacoustic tomography (OT) is now widely used in preclinical imaging; however, the precision (repeatability and reproducibility) of OT has yet to be determined. Methods: We used a commercial small-animal OT system. Measurements in stable phantoms were used to independently assess the impact of system variables on precision (using coefficient of variation, COV), including acquisition wavelength, rotational position, and frame averaging. Variables due to animal handling and physiology, such as anatomic placement and anesthesia conditions, were then assessed in healthy nude mice using the left kidney and spleen as reference organs. Temporal variation was assessed by repeated measurements over hours and days both in phantoms and in vivo. Sensitivity to small-molecule dyes was determined in phantoms and in vivo; precision was assessed in vivo using IRDye800CW. Results: OT COV in a stable phantom was less than 2.8% across all wavelengths over 30 d. The factors with the greatest impact on signal repeatability in phantoms were rotational position and user experience, both of which still resulted in a COV of less than 4% at 700 nm. Anatomic region-of-interest size showed the highest variation, at 12% and 18% COV in the kidney and spleen, respectively; however, functional SO2 measurements based on a standard operating procedure showed an exceptional reproducibility of less than 4% COV. COV for repeated injections of IRDye800CW was 6.6%. Sources of variability for in vivo data included respiration rate, degree of user experience, and animal placement. Conclusion: Data acquired with our small-animal OT system were highly repeatable and reproducible across subjects and over time. Therefore, longitudinal OT studies may be performed with high confidence when our standard operating procedure is followed.

15 October 2018 in Cancer Research
Verified
Journal Article
Open access
PDF file
MTMichal R Tomaszewski
Michal R Tomaszewski
MGMarcel Gehrung
Marcel Gehrung
JJJames Joseph
James Joseph
Isabel Quiros-GonzalezIsabel Quiros-Gonzalez
Isabel Quiros-Gonzalez
JDJonathan A. Disselhorst
Jonathan A. Disselhorst
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Measuring the functional status of tumor vasculature, including blood flow fluctuations and changes in oxygenation, is important in cancer staging and therapy monitoring. Current clinically approved imaging modalities suffer long procedure times and limited spatiotemporal resolution. Optoacoustic tomography (OT) is an emerging clinical imaging modality that may overcome these challenges. By acquiring data at multiple wavelengths, OT can interrogate hemoglobin concentration and oxygenation directly and resolve contributions from injected contrast agents. In this study, we tested whether two dynamic OT techniques, oxygen-enhanced (OE) and dynamic contrast-enhanced (DCE)-OT, could provide surrogate biomarkers of tumor vascular function, hypoxia, and necrosis. We found that vascular maturity led to changes in vascular function that affected tumor perfusion, modulating the DCE-OT signal. Perfusion in turn regulated oxygen availability, driving the OE-OT signal. In particular, we demonstrate for the first time a strong per-tumor and spatial correlation between imaging biomarkers derived from these in vivo techniques and tumor hypoxia quantified ex vivo. Our findings indicate that OT may offer a significant advantage for localized imaging of tumor response to vascular-targeted therapies when compared with existing clinical DCE methods. Significance: Imaging biomarkers derived from optoacoustic tomography can be used as surrogate measures of tumor perfusion and hypoxia, potentially yielding rapid, multiparametric, and noninvasive cancer staging and therapeutic response monitoring in the clinic. Graphical http://cancerres.aacrjournals.org/content/canres/78/20/5980/F1.large.jpg. Cancer Res; 78(20); 5980–91. ©2018 AACR.

26 March 2018 in British Journal of Cancer
Verified
Journal Article
Open access
PDF file
Isabel Quiros-GonzalezIsabel Quiros-Gonzalez
Isabel Quiros-Gonzalez
MTMichal R Tomaszewski
Michal R Tomaszewski
SASarah J. Aitken
Sarah J. Aitken
LALaura Ansel-Bollepalli
Laura Ansel-Bollepalli
LMLeigh-Ann McDuffus
Leigh-Ann McDuffus
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Background Optoacoustic tomography (OT) of breast tumour oxygenation is a promising new technique, currently in clinical trials, which may help to determine disease stage and therapeutic response. However, the ability of OT to distinguish breast tumours displaying different vascular characteristics has yet to be established. The aim of the study is to prove OT as a sensitive technique for differentiating breast tumour models with manifestly different vasculatures. Methods Multispectral OT (MSOT) was performed in oestrogen-dependent (MCF-7) and oestrogen-independent (MDA-MB-231) orthotopic breast cancer xenografts. Total haemoglobin (THb) and oxygen saturation (SO2MSOT) were calculated. Pathological and biochemical evaluation of the tumour vascular phenotype was performed for validation. Results MCF-7 tumours show SO2MSOT similar to healthy tissue in both rim and core, despite significantly lower THb in the core. MDA-MB-231 tumours show markedly lower SO2MSOT with a significant rim–core disparity. Ex vivo analysis revealed that MCF-7 tumours contain fewer blood vessels (CD31+) that are more mature (CD31+/aSMA+) than MDA-MB-231. MCF-7 presented higher levels of stromal VEGF and iNOS, with increased NO serum levels. The vasculogenic process observed in MCF-7 was consistent with angiogenesis, while MDA-MB-231 appeared to rely more on vascular mimicry. Conclusions OT is sensitive to differences in the vascular phenotypes of our breast cancer models.

14 November 2017 in Clinical Cancer Research
Verified
Journal Article
Closed access
PDF file
BXBangwen Xie
Bangwen Xie
MTMichal R Tomaszewski
Michal R Tomaszewski
ANAndré A. Neves
André A. Neves
SRSusana Ros
Susana Ros
DHDe-En Hu
De-En Hu
KBKevin Brindle
Kevin Brindle
Purpose: The development of new treatments and their deployment in the clinic may be assisted by imaging methods that allow an early assessment of treatment response in individual patients. The C2A domain of Synaptotagmin-I (C2Am), which binds to the phosphatidylserine (PS) exposed by apoptotic and necrotic cells, has been developed as an imaging probe for detecting cell death. Multispectral optoacoustic tomography (MSOT) is a real-time and clinically applicable imaging modality that was used here with a near infrared (NIR) fluorophore-labeled C2Am to image tumor cell death in mice treated with a TNF-related apoptosis-inducing ligand receptor 2 (TRAILR2) agonist and with 5-fluorouracil (5-FU). Experimental Design: C2Am was labeled with a NIR fluorophore and injected intravenously into mice bearing human colorectal TRAIL-sensitive Colo205 and TRAIL-resistant HT-29 xenografts that had been treated with a potent agonist of TRAILR2 and in Colo205 tumors treated with 5-FU. Results: Three-dimensional (3D) MSOT images of probe distribution showed development of tumor contrast within 3 hours of probe administration and a signal-to-background ratio in regions containing dead cells of >10 after 24 hours. A site-directed mutant of C2Am that is inactive in PS binding showed negligible binding. Tumor retention of the active probe was strongly correlated (R2 = 0.97, P value < 0.01) with a marker of apoptotic cell death measured in histologic sections obtained post mortem. Conclusions: The rapid development of relatively high levels of contrast suggests that NIR fluorophore-labeled C2Am could be a useful optoacoustic imaging probe for detecting early therapy-induced tumor cell death in the clinic. Clin Cancer Res; 23(22); 6893–903. ©2017 AACR.