chen zhengyu

Dr. chen zhengyu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2022 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
HBHe Bin
He Bin
YZYuxin Zhang
Yuxin Zhang
ZMZhe Meng
Zhe Meng
ZHZhijun He
Zhijun He
CZchen zhengyu
chen zhengyu
Ping XuePing Xue
Ping Xue
Optical coherence tomography angiography (OCTA) can provide depth resolved image of microvasculature but fail to acquire both high resolution and large field imaging of an irregular sample. The robotic arm can easily scan along the sample surface to ensure that the sample at the same depth is all in the same focal plane, so OCTA can be obtained without the effect of unevenly distributed resolution and fall off as occurred in conventional imaging with linear scanning of irregular sample. So, we integrated a 120 kHz OCT with a robotic arm and proposed a novel calibration method for robotic arm with a repeatability positioning accuracy of ∼60μm. A correlation mapping (CM) masked eigen decomposition OCTA was proposed with CM > 0.6 for binarization to improve the vascular visualization and CM > 0.99 for extraction of big vessels to enhance stitching efficacy. With the aid of robotic arm, micro-vascular OCTA of whole mouse brain was achieved for the first time, to our knowledge, over a volume size of 10 mm × 8.1 mm × 1 mm with a resolution of ∼4μm(axial) x ∼6μm(lateral). We believe robot assisted OCTA system will have great potential in biomedical application like intraoperative navigation and other fields.

17 January 2022 in Photonics
Verified
Journal Article
Open access
PDF file
WZWenxin Zhang
Wenxin Zhang
CZchen zhengyu
chen zhengyu
XZXiao Zhang
Xiao Zhang
CWChengming Wang
Chengming Wang
HBHe Bin
He Bin
Ping XuePing Xue
Ping Xue
We propose a novel technique to measure fiber dispersion without any derivative operation and index measurement. Based on the relationship between the dispersion and the signal in optical computing optical coherence tomography, dispersion can be deduced with high accuracy from optical computing OCT signal position and resolution. The group velocity dispersion and third order dispersion of single mode fiber and dispersion compensating fiber with lengths of 10 m–10 km are measured to be in good consistence with the nominal value.

7 February 2020 in IEEE Access
Verified
Journal Article
Open access
SAShengnan Ai
Shengnan Ai
CWChengming Wang
Chengming Wang
WZWenxin Zhang
Wenxin Zhang
JHJui-Cheng Hsieh
Jui-Cheng Hsieh
CZchen zhengyu
chen zhengyu
PXPing Xue
Ping Xue
In this paper, we report a fully automatic method for the prediction of the treatment efficacy of photodynamic therapy during the clinical treatment in port-wine stains. Histogram of oriented gradients (HOG) features were extracted from optical coherence tomography images. Isolation forest (iForest) was used to build classifier based on these features, achieving a sensitivity of 84% and specificity of 91%. Our dataset consists of 336 PWS lesions of 121 patients. We aim to build a comprehensive computational model for the patients who respond positively to the photodynamic therapy, which could be used to sort and identify patients who respond poorly to photodynamic therapy before treatment and prevent them from unnecessary treatment.