Zhe Meng

Zhe Meng

Auto-generated profile, based on publicly available information

Zhe Meng

Department of Neurosurgery, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine and Institute for Precision Medicine, Tsinghua University, Beijing, PR China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
CMChao Ma
Chao Ma
Liyang WangLiyang Wang
Liyang Wang
CGChuntian Gao
Chuntian Gao
DLDongkang Liu
Dongkang Liu
KYKaiyuan Yang
Kaiyuan Yang
GWGuihuai Wang
Guihuai Wang
Patients with hypertensive intracerebral hemorrhage (ICH) have a high hematoma expansion (HE) incidence. Noninvasive prediction HE helps doctors take effective measures to prevent accidents. This study retrospectively analyzed 253 cases of hypertensive intraparenchymal hematoma. Baseline non-contrast-enhanced CT scans (NECTs) were collected at admission and compared with subsequent CTs to determine the presence of HE. An end-to-end deep learning method based on CT was proposed to automatically segment the hematoma region, region of interest (ROI) feature extraction, and HE prediction. A variety of algorithms were employed for comparison. U-Net with attention performs best in the task of segmenting hematomas, with the mean Intersection overUnion (mIoU) of 0.9025. ResNet-34 achieves the most robust generalization capability in HE prediction, with an area under the receiver operating characteristic curve (AUC) of 0.9267, an accuracy of 0.8827, and an F1 score of 0.8644. The proposed method is superior to other mainstream models, which will facilitate accurate, efficient, and automated HE prediction.

16 December 2022 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
HBHe Bin
He Bin
YZYuxin Zhang
Yuxin Zhang
ZMZhe Meng
Zhe Meng
ZHZhijun He
Zhijun He
CZchen zhengyu
chen zhengyu
Ping XuePing Xue
Ping Xue
Optical coherence tomography angiography (OCTA) can provide depth resolved image of microvasculature but fail to acquire both high resolution and large field imaging of an irregular sample. The robotic arm can easily scan along the sample surface to ensure that the sample at the same depth is all in the same focal plane, so OCTA can be obtained without the effect of unevenly distributed resolution and fall off as occurred in conventional imaging with linear scanning of irregular sample. So, we integrated a 120 kHz OCT with a robotic arm and proposed a novel calibration method for robotic arm with a repeatability positioning accuracy of ∼60μm. A correlation mapping (CM) masked eigen decomposition OCTA was proposed with CM > 0.6 for binarization to improve the vascular visualization and CM > 0.99 for extraction of big vessels to enhance stitching efficacy. With the aid of robotic arm, micro-vascular OCTA of whole mouse brain was achieved for the first time, to our knowledge, over a volume size of 10 mm × 8.1 mm × 1 mm with a resolution of ∼4μm(axial) x ∼6μm(lateral). We believe robot assisted OCTA system will have great potential in biomedical application like intraoperative navigation and other fields.