This paper presents a methodology to perform small-signal analysis of an offshore ac network, which is formed by interconnecting several offshore wind power plants. The offshore ac network is connected with different onshore ac grids using point-to-point voltage-source-converter high-voltage direct current (VSC-HVDC) transmission links. In such a network, each offshore VSC-HVDC converter operates in grid-forming mode. In this paper, the offshore VSC grid-forming control is enhanced by using a frequency and voltage droop scheme in order to establish a coordinated grid control among the offshore converters. A small-signal model of the offshore ac network is developed that includes the high-voltage alternating current cables' model, the converters' current, and voltage-control model, the frequency droop scheme, and the voltage droop scheme. Based on this model, an eigenvalue analysis is performed in order to study the influence of the frequency and voltage droop gains on overall offshore ac network stability. Finally, theoretical analysis is validated by performing nonlinear dynamic simulation.
Many offshore wind power plants are being developed every year at North and Baltic Sea. From the prospective of environment and integrated European power, combined power transmission from several offshore wind power plants using VSC-HVDC transmission system to different onshore grids are suitable instead of connecting each wind power plants individually. Offshore AC hub is beneficial for the wind power plants that are far from shore but close to each other within the vicinity of 20 km. This paper presents a method of controlling reactive power flow in the offshore AC grid to minimize the power losses and voltage deviation. In the proposed scheme, offshore grid frequency and voltage are controlled through more than one converter. Using frequency and voltage droop schemes, the active and reactive power sharing is achieved among converters. Furthermore, the optimization algorithm is developed to acquire the set points for the wind power plants and VSC-HVDC droop gains for the optimum operation of the network.Postprint (author's final draft
Offshore wind power generation equipped with conventional grid following controls challenges the power system stability by reducing the inertia of the grid and weakening the AC offshore grid. To overcome this vulnerability a promising solution could be equipping the wind turbines with grid-forming (GFM) control schemes. Many methodologies have been presented in the literature for GFM inverters. In spite of this, their applications for WTGs have not been thoroughly explored. This paper presents the study of fault handling capability of wind turbines with several grid-forming control strategies. In this context, four different control schemes i.e. Visynch, P/f droop, Q/f droop and conventional grid following control are considered. The performance of these control strategies is assessed and compared during a three-phase symmetrical fault on the point of common coupling of an offshore wind farm. A case study which consists of two wind turbines connected to the main converter of an offshore substation equipped with grid-forming control is also considered. The results indicate that, during faults, each of the four control strategies (Visynch, P/f droop, Q/f droop, and Gfol) effectively limits the current and restores normal operation. A significant advantage of Q/F droop control is its reduced sensitivity to variations in system and fault parameters, adjustable frequency response, and independence from existing Phase-Locked Loops (PLLs). On the other hand, the P/f droop control provides greater voltage support during faults due to its voltage controllers. However, post-fault oscillations result from the stiff voltage controller. Visynch control, on the other hand, shows a lower margin of stability. The advantages and weaknesses of each control scheme is revealed using the simulation results.
This research envisages the droop control design of multi voltage source converter systems for offshore networks to integrate wind power plant with the grids. An offshore AC network is formulated by connecting several nearby wind power plants together with AC cables. The net energy in the network is transferred to onshore using voltage source high voltage direct current (VSC-HVDC) transmissionsystems. In the proposed configuration, an offshore network is energized by more than one VSC-HVDC system, hereby providing redundancy to continue operation in case of failure in one of the HVDC transmission lines. The power distribution between VSC-HVDC systems is done using a droop control scheme. Frequency droop is implemented to share active power, and voltage droop is implemented to share reactive power. Furthermore, a method of calculating droop gains according to the contribution factor of each converter is presented. The system has been analyzed to evaluate the voltage profile of the network affected by the droop control. Nonlinear dynamic simulation has been performed for the verification of the control principle.