Eduardo Prieto-Araujo

Dr. Eduardo Prieto-Araujo

Centre d’Innovació Tecnològica en Convertidors Estàtics i Accionaments (CITCEA-UPC), Universitat Politècnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2, 08028 Barcelona, Spain
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2011 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Eduardo Prieto-AraujoEduardo Prieto-Araujo
Eduardo Prieto-Araujo
FBFernando D. Bianchi
Fernando D. Bianchi
AJAdrià Junyent-Ferre
Adrià Junyent-Ferre
Oriol Gomis-BellmuntOriol Gomis-Bellmunt
Oriol Gomis-Bellmunt
This paper addresses the control of multiterminal voltage-source converters at high-voltage direct current in the context of offshore wind farms. Droop control is commonly used to regulate the dc voltage in this kind of grid, and droop parameters are selected on the basis of steady-state analyses. Here, a control design methodology is proposed based on the frequency-response analysis. This methodology provides a criterion to select the droop gains, taking into account the performance specifications [i.e., the desired voltage errors and the maximum control inputs (currents)]. The application of the methodology is illustrated with a four-terminal grid.

5 September 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Oriol Gomis-BellmuntOriol Gomis-Bellmunt
Oriol Gomis-Bellmunt
JSJoan Sau-Bassols
Joan Sau-Bassols
Eduardo Prieto-AraujoEduardo Prieto-Araujo
Eduardo Prieto-Araujo
Marc Cheah MañéMarc Cheah Mañé
Marc Cheah Mañé
Flexible Alternating Current Transmission Systems (FACTS) have achieved to enhance the flexibility of modern AC power systems, by providing fast, reliable and controllable solutions to steer the power flows and voltages in the network. The proliferation of High Voltage Direct Current (HVDC) transmission systems is leading to the opportunity of interconnecting several HVDC systems forming HVDC Supergrids. Such grids can eventually evolve to meshed systems which interconnect a number of different AC power systems and large scale offshore wind (or other renewable sources) power plants and clusters. While such heavily meshed systems can be considered futuristic and will not certainly happen in the near future, the sector is witnessing initial steps in this direction. In order to ensure the flexibility and controllability of meshed DC grids, the shunt connected AC-DC converters can be combined with additional simple and flexible DC-DC converters which can directly control current and power through the lines. The proposed DC-DC converters can provide a range of services to the HVDC grid, including power flow control capability, ancillary services for the HVDC grid or adjacent grids, stability improvement, oscillation damping, pole balancing and voltage control. The present paper presents relevant developments from industry and academia in the direction of the development of these converters, considering technical concepts, converter functionalities and possible integration with other existing systems. The paper explores a possible vision on the development of future meshed HVDC grids and discusses the role of the proposed converters in such grids.

25 April 2024 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
HXHuanhai Xin
Huanhai Xin
CLChenxi Liu
Chenxi Liu
XCXia Chen
Xia Chen
YWYuxuan Wang
Yuxuan Wang
Eduardo Prieto-AraujoEduardo Prieto-Araujo
Eduardo Prieto-Araujo
LHLinbin Huang
Linbin Huang
Grid-forming (GFM) control has been considered a promising solution for accommodating large-scale power electronics converters into modern power grids thanks to its grid-friendly dynamics, in particular, voltage source behavior on the AC side. The voltage source behavior of GFM converters can provide voltage support for the power grid, and therefore enhance the power grid (voltage) strength. However, grid-following (GFL) converters can also perform constant AC voltage magnitude control by properly regulating their reactive current, which may also behave like a voltage source. Currently, it still remains unclear what are the essential differences between the voltage source behaviors of GFL and GFM converters, and which type of voltage source behavior can enhance the power grid strength. In this paper, we will demonstrate that only GFM converters can provide effective voltage source behavior and enhance the power grid strength in terms of small signal dynamics. Based on our analysis, we further study the problem of how to configure GFM converters in the grid and how many GFM converters we will need. We investigate how the capacity ratio between GFM and GFL converters affects the equivalent power grid strength and thus the small signal stability of the system. We give guidelines on how to choose this ratio to achieve a desired stability margin. We validate our analysis using high-fidelity simulations.

22 March 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
MCMeng Chen
Meng Chen
Dao ZhouDao Zhou
Dao Zhou
ATAli Tayyebi
Ali Tayyebi
Eduardo Prieto-AraujoEduardo Prieto-Araujo
Eduardo Prieto-Araujo
FDFlorian Dorfler
Florian Dorfler
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
The grid-forming converter is an important unit in the future power system with more inverter-interfaced generators. However, improving its performance is still a key challenge. This paper proposes a generalized architecture of the grid-forming converter from the view of multivariable feedback control. As a result, many of the existing popular control strategies, i.e., droop control, power synchronization control, virtual synchronous generator control, matching control, dispatchable virtual oscillator control, and their improved forms are unified into a multivariable feedback control transfer matrix working on several linear and nonlinear error signals. Meanwhile, unlike the traditional assumptions of decoupling between AC and DC control, active power and reactive power control, the proposed configuration simultaneously takes all of them into consideration, which therefore can provide better performance. As an example, a new multi-input-multi-output-based grid-forming (MIMO-GFM) control is proposed based on the generalized configuration. To cope with the multivariable feedback, an optimal and structured $\mathcal {H}_{\infty }$ synthesis is used to design the control parameters. At last, simulation and experimental results show superior performance and robustness of the proposed configuration and control.

25 April 2023 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
STSaman Dadjo Tavakoli
Saman Dadjo Tavakoli
MDMehdi Ghazavi Dozein
Mehdi Ghazavi Dozein
VLVinícius Albernaz Lacerda
Vinícius Albernaz Lacerda
Marc Cheah MañéMarc Cheah Mañé
Marc Cheah Mañé
Eduardo Prieto-AraujoEduardo Prieto-Araujo
Eduardo Prieto-Araujo
Oriol Gomis-BellmuntOriol Gomis-Bellmunt
Oriol Gomis-Bellmunt
Hydrogen electrloyzers are power-to-gas storage devices that can facilitate large-scale integration of intermittent renewable sources into the future power systems. Due to their fast response and capability to operate in different loading conditions, they can be used as responsive loads providing support to AC grid during transients. This paper suggests taking one step further and using hydrogen electrolyzers to provide grid-forming services to the grid. As a result, the electrolyzer's role is elevated from supporting the grid (responsive load) to actively participating in forming voltage and frequency of the grid. The grid-forming capability of electrolyzer is linked to its hydrogen production constraints, which can potentially pose limitations on the grid-forming services. Besides the grid-forming mode, two additional operating modes, i.e., DC voltage mode and constant power mode, are proposed to ensure a safe operation of the electrolyzer in case of adversary interaction between grid-forming operation and hydrogen production constraints. This paper also studies the impacts of grid-forming services on the electrolyzer's physical features such as hydrogen stack temperature and efficiency. Comprehensive simulations are conducted on a low-inertia test network whose topology is inspired by a portion of the transmission grid in South Australia to confirm the effectiveness of the proposed concept under various operational conditions of the electrolyzer and upstream AC grid. Moreover, the practical feasibility of the proposed control system is experimentally validated by conducting hardware-in-the-loop tests.

30 June 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Eduardo Prieto-AraujoEduardo Prieto-Araujo
Eduardo Prieto-Araujo
Agusti Egea AlvarezAgusti Egea Alvarez
Agusti Egea Alvarez
SFSajjad Fekriasl
Sajjad Fekriasl
Oriol Gomis-BellmuntOriol Gomis-Bellmunt
Oriol Gomis-Bellmunt
This paper focuses on the droop-based dc voltage control design for multiterminal VSC-HVDC grid systems, considering the ac and the dc system dynamics. The droop control design relies on detailed linearized models of the complete multiterminal grid, including the different system dynamics, such as the dc grid, the ac grid, the ac connection filters, and the converter inner controllers. Based on the derived linear models, classical and modern control techniques are applied to design the different controllers, including a multivariable frequency analysis to design the grid voltage droop control. In combination with the droop control, a dc oscillation damping scheme is proposed in order to improve system performance. The control design is validated through simulations of a three-terminal system.