Hesam Rahbarimagham

Prof. Hesam Rahbarimagham


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YZYali Zeng
Yali Zeng
ZHZahraa Abed Hussein
Zahraa Abed Hussein
MCMustafa Habeeb Chyad
Mustafa Habeeb Chyad
AFAmirfarhad Farhadi
Amirfarhad Farhadi
JYJianyong Yu
Jianyong Yu
HRHesam Rahbarimagham
Hesam Rahbarimagham
The increasing complexity of hydropower systems necessitates advanced control strategies to optimize performance and enhance system reliability. This paper presents a novel approach that integrates Type-2 Fuzzy Logic Controllers (T2FLC), Digital Twin technology, and Neural Networks for comprehensive management of hydropower systems. The proposed hybrid system aims to improve load management, fault detection, and operational efficiency. Our method employs a Type-2 Fuzzy Logic Controller to handle uncertainty and imprecision in system control. The Digital Twin creates a dynamic simulation model of the hydropower system, allowing real-time monitoring and predictive analysis. Neural Networks further enhance this system by providing predictive insights based on historical and real-time data. Specifically, the hybrid system achieved a 10.96% increase in load management efficiency and a 12.64% reduction in fault detection time compared to traditional methods. The Digital Twin model contributed to a 18.21% improvement in predictive accuracy, while the Neural Networks enhanced control decisions, resulting in a 8.05% reduction in operational deviations. Furthermore, the proposed approach showed a 11.48% improvement in overall system reliability and a 13.04% reduction in maintenance costs, illustrating the practical benefits of integrating advanced control and predictive technologies. These results underscore the effectiveness of combining T2FLC, Digital Twin, and Neural Networks, offering a substantial advancement in hydropower system management. The proposed method not only enhances system performance but also provides a robust framework for future advancements in intelligent control strategies.

23 March 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HRHesam Rahbarimagham
Hesam Rahbarimagham
HKHossein Karami
Hossein Karami
MHMaryam Sadat Akhavan Hejazi
Maryam Sadat Akhavan Hejazi
MNMahdi S. Naderi
Mahdi S. Naderi
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
Online monitoring of the transformer winding using electromagnetic waves has recently been proposed for the detection of mechanical defects of transformer winding. In this paper, a new method, which uses the ultrawideband radar measurement results and is based on locus of objects in the space, is proposed for the 3-D positioning of transformer winding radial deformation location. The proposed experimental setup for this method named hyperboloid method is modeled using Computer Simulation Technology software. In this paper, Vivaldi antennas suitable for measurements in environments with multipath, are used and the analysis is performed in the time domain. The simulation results show that the exact 3-D location of the radial deformation can be detected with a good accuracy.

23 January 2025 in IEEE Access
Verified
Journal Article
Open access
ASAbbas Safari
Abbas Safari
HRHesam Rahbarimagham
Hesam Rahbarimagham
Nowadays, interface converters based hybrid AC/DC microgrids have gained great interests in smart grids. The interface converters can perform tasks such as accurate power sharing, power quality enhancement, bidirectional power transmission, and so on by using advanced and accurate control strategies. In this work, a dc voltage droop based hierarchical control is introduced for bidirectional power transfer by an interface converter in a hybrid AC/DC microgrid. This proposed approach can exchange active power between AC or DC subgrids according to the requirement of each subgrid with slight DC voltage deviation around its nominal value. Moreover, a reactive power control algorithm is presented which can compensate the reactive power of the AC subgrid based on the interface converter’s maximum rated capacity. Also, the impact of the participation of electric vehicles in the DC subgrid on the improvement of reactive power management and the capacity reduction of the interface converter is investigated. Another droop control is considered in the voltage control loop of the bidirectional boost converter in the electric vehicle to determine the participation rate of the electric vehicle in reactive power management through the charging and discharging of its battery storage system. The simulation results in Simulink MATLAB software illustrate that the compensation of reactive power by the interface converter improves significantly by employing the proposed control method and the maximum participation of electric vehicles, leading to a decrease in the rated capacity of the interface converter.

26 May 2025 in Energy Conversion and Management: X
Verified
Journal Article
Open access
MHMojtaba Hadi
Mojtaba Hadi
Elhoussin ElbouchikhiElhoussin Elbouchikhi
Elhoussin Elbouchikhi
Zhibin ZhouZhibin Zhou
Zhibin Zhou
ASAbdelhakim Saim
Abdelhakim Saim
MSMiadreza Shafie-Khah
Miadreza Shafie-Khah
PCPau Marti Colom
Pau Marti Colom

27 March 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HRHesam Rahbarimagham
Hesam Rahbarimagham
SESaeid Esmaeili
Saeid Esmaeili
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
In this paper, three monitoring stages of detection, localization, and extent determination of radial deformation in power transformer winding using stationary ultra-wideband (UWB) antennas, are investigated. For this purpose, two types of radial deformation are implemented on the actual transformer high-voltage (HV) winding. The first type is a modeled bulgy mechanical deformation, which its extent and reversibility may be changed and it can occur in different positions. The second type is an actual radial deformation applied to the winding. Hyperboloid method and two-dimensional (2-D) locus of the winding are adopted in the localization stage. To perform a precise analysis of the received signals, matched filter technique is employed. The extent of the deformation is also determined by magnitude euclidean distance (MED) index. The experimental results prove the effectiveness of the proposed method.

1 July 2018 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
HRHesam Rahbarimagham
Hesam Rahbarimagham
SESaeid Esmaeili
Saeid Esmaeili
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
In this study, a new method is proposed to monitor axial displacement (AD) of transformer high‐voltage (HV) winding using electromagnetic waves. The proposed method employed two receiving antennas and one transmitting antenna to exchange ultra‐wideband (UWB) signals with the winding. The magnitude Euclidean distance (MED) index is used to compare the received signals when winding is sound or defective. Two receiving antennas receive signals at two different positions upon ADs in winding which causes different values in the amplitude of the received signals as well as the MED index of two receiving antennas. Hence, taking advantage of this feature, the occurrence, direction, and extent of AD can be identified. The proposed method is assessed using a simulation model. Then, experiments are conducted on an actual transformer winding using an experimental setup.