Kiyoung Shin

Dr. Kiyoung Shin


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KSKiyoung Shin
Kiyoung Shin
RMRyan McConville
Ryan McConville
OMOussama Metatla
Oussama Metatla
MCMinhye Chang
Minhye Chang
CHChiyoung Han
Chiyoung Han
Anne RoudautAnne Roudaut
Anne Roudaut
One of the major challenges for blind and visually impaired (BVI) people is traveling safely to cross intersections on foot. Many countries are now generating audible signals at crossings for visually impaired people to help with this problem. However, these accessible pedestrian signals can result in confusion for visually impaired people as they do not know which signal must be interpreted for traveling multiple crosses in complex road architecture. To solve this problem, we propose an assistive system called CAS (Crossing Assistance System) which extends the principle of the BLE (Bluetooth Low Energy) RSSI (Received Signal Strength Indicator) signal for outdoor and indoor location tracking and overcomes the intrinsic limitation of outdoor noise to enable us to locate the user effectively. We installed the system on a real-world intersection and collected a set of data for demonstrating the feasibility of outdoor RSSI tracking in a series of two studies. In the first study, our goal was to show the feasibility of using outdoor RSSI on the localization of four zones. We used a k-nearest neighbors (kNN) method and showed it led to 99.8% accuracy. In the second study, we extended our work to a more complex setup with nine zones, evaluated both the kNN and an additional method, a Support Vector Machine (SVM) with various RSSI features for classification. We found that the SVM performed best using the RSSI average, standard deviation, median, interquartile range (IQR) of the RSSI over a 5 s window. The best method can localize people with 97.7% accuracy. We conclude this paper by discussing how our system can impact navigation for BVI users in outdoor and indoor setups and what are the implications of these findings on the design of both wearable and traffic assistive technology for blind pedestrian navigation.

4 January 2013 in Sensors
Verified
Journal Article
Open access
PDF file
SYSeong Ki Yoo
Seong Ki Yoo
KSKiyoung Shin
Kiyoung Shin
TLTae-Bum Lee
Tae-Bum Lee
SJSeung-Oh Jin
Seung-Oh Jin
Jaeuk KimJaeuk Kim
Jaeuk Kim
Several RPT sensors have been developed to acquire objective and quantitative pulse waves. These sensors offer improved performance with respect to pressure calibration, size and sensor deployment, but not temperature. Since most pressure sensors are sensitive to temperature, various temperature compensation techniques have been developed, but these techniques are largely inapplicable to RPT sensors due to the size restrictions of the sensor, and incompatibility between the compensation techniques and the RPT sensor. Consequently, in this paper a new RPT sensor comprising six piezoresistive pressure sensors and one thermistor has been developed through finite element analysis and then a suitable temperature compensation technique has been proposed. This technique compensates for temperature variations by using the thermistor and simple compensation equations. As verification of the proposed compensation technique, pulse waves of all types were successfully compensated for temperature changes.

27 August 2013 in SpringerPlus
Verified
Journal Article
Open access
PDF file
SYSeong Ki Yoo
Seong Ki Yoo
KSKiyoung Shin
Kiyoung Shin
TLTae Bum Lee
Tae Bum Lee
SJSeung Oh Jin
Seung Oh Jin
In traditional Chinese and Korean medicine, doctors first observe a patient’s pulse by gently and strongly pressing their fingers onto the wrist, and then make a diagnosis based on the observed pulse waves. The most common method to implement this diagnostic technique is to mechanically extract the pulse waves by applying a fixed range of pressures for all patients. However, this method does not consider the patients individual characteristics such as age, sex, and skin thickness. In the present study, we propose a new method of pulse wave extraction that incorporates the personal characteristics of the patients. This method measures the pulse wave signal at varying hold-down pressures, rather than applying a fixed hold-down pressure for all patients. To compare this new technique with existing methods, we extracted pulse waves from 20 subjects, and then determined the actual applied pressure at each step, the coefficient of floating and sinking pulse (CFS), and the distinction of floating/sinking pulse for each group. Consequently, each subject had a different pressure range in our proposed method, whereas all subjects had a similar pressure range in the existing method. Four of 20 subjects exhibited different floating/sinking pulse patterns due to the value of the first pressure step and the range of hold-down pressures. These four subjects were categorized as overweight based on BMI. In addition, the moving distance of the proposed method was longer than the existing method (p = 0.003, paired t-test), and the correlation coefficient between CFS values of two different methods was 0.321, indicating that there was no correlation.


1 February 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SKSanghoon Kim
Sanghoon Kim
YLYong-Seok Lee
Yong-Seok Lee
GKGeun-Ju Kim
Geun-Ju Kim
JLJeong-Hun Lee
Jeong-Hun Lee
KIKim Insung
Kim Insung
JKJung-Il Kim
Jung-Il Kim
A compact X-band linear accelerator (LINAC) system equipped with a small and lightweight magnetron was constructed to develop a high-precision image-guided radiotherapy system. The developed LINAC system was installed in an O-ring gantry where cone-beam computed tomography (CBCT) was embedded. When the O-arm gantry is rotated, an x-ray beam is stably generated, which resulted from the stable transmission of radio frequency power into the X-band LINAC system. Quality assurance (QA) tests, including mechanical and dosimetry checks, were carried out to ensure safety and operation performance according to the American Association of Physicists in Medicine’s TG-51, 142, an international standard protocol established by accredited institutions. In addition, delivery QA of the radiotherapy planning system was conducted to verify intensity-modulated radiotherapy techniques. Therefore, it was demonstrated that the developed X-band LINAC system mounted on the O-arm gantry proved to be valid and reliable for potential use in CBCT image-guided radiation therapy.

1 August 2012
Verified
Conference Paper
Closed access
KSKiyoung Shin
Kiyoung Shin
TLT. B. Lee
T. B. Lee
SJS. O. Jin
S. O. Jin
SCS. H. Choi
S. H. Choi
SYSeong Ki Yoo
Seong Ki Yoo
JKJ. Y. Kim
J. Y. Kim
Chronic gastritis is a disease that occurs in one in every 10 persons in Korea. Endoscopic examination is needed to diagnose chronic gastritis in western medicine, but it causes patients pain, long period of examinations and financial burden. In KM (Korean Medicine), on the other hand, it can be known whether stomach is abnormal or not through a pulse diagnosis. The `Guan' position of the right wrist is related to a stomach in KM. Thus, the pulse wave of the right-hand “Guan” of patients with chronic gastritis and the healthy were measured. Then, the diagnostic parameter and features to distinguish between the patients with chronic gastritis and the healthy were discovered. Through P-H curve, consequently, it can be concluded that the pulse waves of patients with chronic gastritis appear as a floating pulse, whereas the pulse waves of the healthy appear as a normal pulse.