Ghada Ahmed Khouqeer

Dr. Ghada Ahmed Khouqeer

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
FAFatma E. AlTahhan
Fatma E. AlTahhan
GKGhada Ahmed Khouqeer
Ghada Ahmed Khouqeer
SSSarmad Saadi
Sarmad Saadi
AEAhmed Elgarayhi
Ahmed Elgarayhi
Mohammed SallahMohammed Sallah
Mohammed Sallah
Refined hybrid convolutional neural networks are proposed in this work for classifying brain tumor classes based on MRI scans. A dataset of 2880 T1-weighted contrast-enhanced MRI brain scans are used. The dataset contains three main classes of brain tumors: gliomas, meningiomas, and pituitary tumors, as well as a class of no tumors. Firstly, two pre-trained, fine-tuned convolutional neural networks, GoogleNet and AlexNet, were used for classification process, with validation and classification accuracy being 91.5% and 90.21%, respectively. Then, to improving the performance of the fine-tuning AlexNet, two hybrid networks (AlexNet-SVM and AlexNet-KNN) were applied. These hybrid networks achieved 96.9% and 98.6% validation and accuracy, respectively. Thus, the hybrid network AlexNet-KNN was shown to be able to apply the classification process of the present data with high accuracy. After exporting these networks, a selected dataset was employed for testing process, yielding accuracies of 88%, 85%, 95%, and 97% for the fine-tuned GoogleNet, the fine-tuned AlexNet, AlexNet-SVM, and AlexNet-KNN, respectively. The proposed system would help for automatic detection and classification of the brain tumor from the MRI scans and safe the time for the clinical diagnosis.

9 November 2023 in Journal of Molecular Structure
Verified
Journal Article
Closed access
YDYahnis Dago-Serry
Yahnis Dago-Serry
KMKonstantinos Maroulas
Konstantinos Maroulas
Athanasia K. TolkouAthanasia K. Tolkou
Athanasia K. Tolkou
NANaglaa AbdelAll
Naglaa AbdelAll
AAAbdullah Alodhayb
Abdullah Alodhayb
George Z. KyzasGeorge Z. Kyzas
George Z. Kyzas

7 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
RPRajendran Prabakaran
Rajendran Prabakaran
PDP. Dhamodharan
P. Dhamodharan
ASA Sathishkumar
A Sathishkumar
Paride GulloParide Gullo
Paride Gullo
PMPonrajan Vikram M
Ponrajan Vikram M
SKSung Chul Kim
Sung Chul Kim
Building cooling and heating, solar-powered energy production, energy recovery, and other energy-consuming industries have all seen an increase in the use of cold/hot latent thermal energy storage (LH-TES). Through energy recovery, LH-TES that uses phase-change materials (PCMs) as a storage medium helps to close the energy supply and demand gap and raises the possibility of energy savings. However, the stability, thermal, physical, and chemical properties of the PCM play a major role in how effectively it can be used. In recent years, adding gelling and thickening agents (GTAs) has gained popularity apart from the nanoparticles (NPs) and nucleating triggers (NTs), particularly for the creation of stable PCMs. Therefore, the current work’s goal is to provide an overview of how GTAs are used in the process of developing reliable PCMs for TES applications. It has been found that using GTAs not only increased stability but also decreased sedimentation, leakage, and the supercooling degree (SCD). It was noted that the addition of a GTA with a weight percentage of 2–15% resulted in excellent stability with a negligible leakage rate and latent heat reduced by 3.6–35% after only 200 cycles. Furthermore, PCMs for solar-thermal and building heating systems in the medium-temperature range (21–61 °C) were mostly studied for their performance with GTAs, but no study for a cool TES application was reported. Most works have studied inorganic PCM components with GTAs, and a few reports are available for paraffin. However, the GTA blending resulted in reduced thermal performance due to a decrease in thermal conductivity, latent heat, and a rise in viscosity. Further, NTs and NPs with small amounts were seeded into the PCM-GTA for eradicating the SCD with enhanced TC and accelerated energy transfer.

12 April 2023 in Life
Verified
Journal Article
Open access
PDF file
ISIbrahim Idris Suliman
Ibrahim Idris Suliman
GKGhada Ahmed Khouqeer
Ghada Ahmed Khouqeer
NANada A. Ahmed
Nada A. Ahmed
MAMohamed M. Abuzaid
Mohamed M. Abuzaid
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
Chest computed tomography (CT) plays a vital role in the early diagnosis, treatment, and follow-up of COVID-19 pneumonia during the pandemic. However, this raises concerns about excessive exposure to ionizing radiation. This study aimed to survey radiation doses in low-dose chest CT (LDCT) and ultra-low-dose chest CT (ULD) protocols used for imaging COVID-19 pneumonia relative to standard CT (STD) protocols so that the best possible practice and dose reduction techniques could be recommended. A total of 564 articles were identified by searching major scientific databases, including ISI Web of Science, Scopus, and PubMed. After evaluating the content and applying the inclusion criteria to technical factors and radiation dose metrics relevant to the LDCT protocols used for imaging COVID-19 patients, data from ten articles were extracted and analyzed. Technique factors that affect the application of LDCT and ULD are discussed, including tube current (mA), peak tube voltage (kVp), pitch factor, and iterative reconstruction (IR) algorithms. The CTDIvol values for the STD, LDCT, and ULD chest CT protocols ranged from 2.79–13.2 mGy, 0.90–4.40 mGy, and 0.20–0.28 mGy, respectively. The effective dose (ED) values for STD, LDCT, and ULD chest CT protocols ranged from 1.66–6.60 mSv, 0.50–0.80 mGy, and 0.39–0.64 mSv, respectively. Compared with the standard (STD), LDCT reduced the dose reduction by a factor of 2–4, whereas ULD reduced the dose reduction by a factor of 8–13. These dose reductions were achieved by applying scan parameters and techniques such as iterative reconstructions, ultra-long pitches, and fast spectral shaping with a tin filter. Using LDCT, the cumulative radiation dose of serial CT examinations during the acute period of COVID-19 may have been inferior or equivalent to that of conventional CT.

1 May 2025 in Journal of Molecular Structure
Verified
Journal Article
Closed access
KMKeerthi S. Mathad
Keerthi S. Mathad
GKGhada Ahmed Khouqeer
Ghada Ahmed Khouqeer
MSMadasu Sreenivasulu
Madasu Sreenivasulu
NANaglaa AbdelAll
Naglaa AbdelAll
AAAbdullah Alodhayb
Abdullah Alodhayb
NSNagaraj P. Shetti
Nagaraj P. Shetti

14 January 2023 in Toxics
Verified
Journal Article
Open access
PDF file
ISIbrahim Idris Suliman
Ibrahim Idris Suliman
GKGhada Ahmed Khouqeer
Ghada Ahmed Khouqeer
FMFareed H. Mayhoub
Fareed H. Mayhoub
Herein, we evaluated the neutron and gamma capture dose equivalent rates at the maze entrance of Varian TrueBeam and Elekta Versa HD™ medical linear accelerators (linacs) using experimental measurements as well as empirical calculations. Dose rates were measured using calibrated neutron and gamma area survey meters placed side-by-side at the measurement point of interest. Measurements were performed at a source-to-detector distance of 100 cm, with a 10 × 10 cm2 field size therapeutic X-ray beam, and a 30 × 30 × 15 cm3 solid water patient equivalent phantom, with a linac operating at 15, 10 MV, and 10 MV flattened filter-free (FFF). Dose rates were also measured at different points at the centerline along the maze towards the maze entrance. The measured dose equivalent rates at the maze entrance were comparable to those reported in the literature. The dose rates along the maze decreased exponentially towards the maze entrance and were significant for short maze lengths. The evaluated empirical methods for estimating neutron dose rates at the maze entrance of a linac proposed by Kersey, the modified Kersey method and Falcão method, agree by a factor of two from the experimental measurements. The results revealed vital radiation protection considerations owing to neutron contamination in external beam therapy.