José Luis Marqués-Fernández

Mr. José Luis Marqués-Fernández

Research
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
María SalvadorMaría Salvador
María Salvador
JMJosé Luis Marqués-Fernández
José Luis Marqués-Fernández
ABAlexander Bunge
Alexander Bunge
JMJosé Carlos Martínez-García
José Carlos Martínez-García
Rodica TurcuRodica Turcu
Rodica Turcu
MRMontserrat Rivas
Montserrat Rivas
Lateral flow immunoassays for detecting biomarkers in body fluids are simple, quick, inexpensive point-of-care tests widely used in disease surveillance, such as during the coronavirus disease 2019 (COVID-19) pandemic. Improvements in sensitivity would increase their utility in healthcare, food safety, and environmental control. Recently, biofunctional magnetic nanoclusters have been used to selectively label target proteins, which allows their detection and quantification with a magneto-inductive sensor. This type of detector is easily integrated with the lateral flow immunoassay format. Pneumolysin is a cholesterol-dependent cytolysin and one of the most important protein virulence factors of pneumonia produced by Streptococcus pneumoniae. It is recognized as an important biomarker for diagnosis in urine samples. Pneumonia is the infectious disease that causes the most deaths globally, especially among children under five years and adults over 65 years, most of them in low- and middle-income countries. There especially, a rapid diagnostic urine test for pneumococcal pneumonia with high sensitivity and specificity would be helpful in primary care. In this work, a lateral flow immunoassay with magnetic nanoclusters conjugated to anti-pneumolysin antibodies was combined with two strategies to increase the technique’s performance. First, magnetic concentration of the protein before the immunoassay was followed by quantification by means of a mobile telephone camera, and the inductive sensor resulted in detection limits as low as 0.57 ng (telephone camera) and 0.24 ng (inductive sensor) of pneumolysin per milliliter. Second, magnetic relocation of the particles within the test strip after the immunoassay was completed increased the detected signal by 20%. Such results obtained with portable devices are promising when compared to non-portable conventional pneumolysin detection techniques such as enzyme-linked immunosorbent assays. The combination and optimization of these approaches would have excellent application in point-of-care biodetection to reduce antibiotic misuse, hospitalizations, and deaths from community-acquired pneumonia.

8 January 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
María SalvadorMaría Salvador
María Salvador
JMJosé Luis Marqués-Fernández
José Luis Marqués-Fernández
JMJosé Carlos Martínez-García
José Carlos Martínez-García
DFDino Fiorani
Dino Fiorani
PAPaolo Arosio
Paolo Arosio
MRMontserrat Rivas
Montserrat Rivas
Today, public health is one of the most important challenges in society. Cancer is the leading cause of death, so early diagnosis and localized treatments that minimize side effects are a priority. Magnetic nanoparticles have shown great potential as magnetic resonance imaging contrast agents, detection tags for in vitro biosensing, and mediators of heating in magnetic hyperthermia. One of the critical characteristics of nanoparticles to adjust to the biomedical needs of each application is their polymeric coating. Fatty acid coatings are known to contribute to colloidal stability and good surface crystalline quality. While monolayer coatings make the particles hydrophobic, a fatty acid double-layer renders them hydrophilic, and therefore suitable for use in body fluids. In addition, they provide the particles with functional chemical groups that allow their bioconjugation. This work analyzes three types of self-assembled bilayer fatty acid coatings of superparamagnetic iron oxide nanoparticles: oleic, lauric, and myristic acids. We characterize the particles magnetically and structurally and study their potential for resonance imaging, magnetic hyperthermia, and labeling for biosensing in lateral flow immunoassays. We found that the myristic acid sample reported a large r2 relaxivity, superior to existing iron-based commercial agents. For magnetic hyperthermia, a significant specific absorption rate value was obtained for the oleic sample. Finally, the lauric acid sample showed promising results for nanolabeling.

21 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JMJosé Luis Marqués-Fernández
José Luis Marqués-Fernández
María SalvadorMaría Salvador
María Salvador
JMJosé Carlos Martínez-García
José Carlos Martínez-García
Pablo Fernandez MiajaPablo Fernandez Miaja
Pablo Fernandez Miaja
AGAlfredo Garcia-Arribas
Alfredo Garcia-Arribas
MRMontserrat Rivas
Montserrat Rivas
We demonstrate how resonant planar coils may be used as sensors to detect and quantify magnetic nanoparticles reliably. A coil’s resonant frequency depends on the adjacent materials’ magnetic permeability and electric permittivity. A small number of nanoparticles dispersed on a supporting matrix on top of a planar coil circuit may thus be quantified. Such nanoparticle detection has application detection to create new devices to assess biomedicine, food quality assurance, and environmental control challenges. We developed a mathematical model for the inductive sensor response at radio frequencies to obtain the nanoparticles’ mass from the self-resonance frequency of the coil. In the model, the calibration parameters only depend on the refraction index of the material around the coil, not on the separate magnetic permeability and electric permittivity. The model compares favourably with three-dimensional electromagnetic simulations and independent experimental measurements. The sensor can be scaled and automated in portable devices to measure small quantities of nanoparticles at a low cost. The resonant sensor combined with the mathematical model is a significant improvement over simple inductive sensors, which operate at smaller frequencies and do not have the required sensitivity, and oscillator-based inductive sensors, which focus on just magnetic permeability.

9 September 2025 in IEEE Sensors Journal
Verified
Journal Article
Open access
JMJosé Luis Marqués-Fernández
José Luis Marqués-Fernández
MFMaría Salvador Fernández
María Salvador Fernández
JMJosé Carlos Martínez-García
José Carlos Martínez-García
MRMontserrat Rivas
Montserrat Rivas
This work uses a custom oscillator circuit to explore an inductive-capacitive approach to nanoparticle quantification. The development of quantitative lateral flow tests has prompted the design of devices that can assess the number of detection markers at the test line. These markers include latex, gold, silver, and magnetic nanoparticles. The aim is to provide quantification without compromising the typical advantages of lateral flow assays: ease of use, portability, and low cost. In previous work, we described a sensor based on a coil’s self-resonant frequency (SRF) for high-precision detection of both magnetic and nonmagnetic nanoparticles. The realization of such a device requires a reliable measurement of the SRF. Here, we face this challenge by introducing a new broadband L-C oscillator that transforms the sensing coil’s impedance curve into a frequency power spectrum. This allows for straightforward, fast, and robust SRF detection. The oscillator is based on an ad-hoc astable circuit supported by theoretical modeling, simulations, and experimental validation. We call this oscillator astable tuned oscillator (ATO). Coupled with a frequency counter, the system enables quantification of microgram levels of various nanoparticles. A detection limit of 650 ng was achieved for magnetite nanoparticles using a compact and cost-effective setup. Beyond biosensing, the oscillator can support inductive sensing applications where slight variations in coil response are used to detect changes in materials or environments, such as in structural monitoring, material inspection, or soft matter characterization.