Nowadays, finishing operation in hardened steel parts which have wide industrial applications is done by hard turning. Cubic boron nitride (CBN) inserts, which are expensive, are used for hard turning. The cheaper coated carbide tool is seen as a substitute for CBN inserts in the hardness range (45–55 HRC). However, tool wear in a coated carbide tool during hard turning is a significant factor that influences the tolerance of machined surface. An online tool wear estimation system is essential for maintaining the surface quality and minimizing the manufacturing cost. In this investigation, the cutting tool wear estimation using artificial neural network (ANN) is proposed. AISI4140 steel hardened to 47 HRC is used as a work piece and a coated carbide tool is the cutting tool. Experimentation is based on full factorial design (FFD) as per design of experiments. The variations in cutting forces and vibrations are measured during the experimentation. Based on the process parameters and measured parameters an ANN-based tool wear estimator is developed. The wear outputs from the ANN model are then tested. It was observed that as the model using ANN provided quite satisfactory results, and that it can be used for online tool wear estimation.
Biomedical implants are immensely manoeuvered devices that fix various deformities and injuries on medical grounds. With an emergent exploration in this field by researchers, countless combinations of materials have been discovered that perks global mankind. The ultimate goal of this experimentation is to appraise the characteristics of wear and corrosion resistance of Ti–Co–Cr-coated 316L grade austenitic stainless steel (SS) in contrast with TiN-coated and uncoated 316L SS. A micro-abrasion test was conducted on every single sample at 3N, 5N and 7N loads and were characterized in accordance with weight loss, coefficient of friction, surface roughness, Scanning Electron Microscope (SEM) analysis, X-ray Diffraction pattern (XRD), Energy Dispersive X-Ray Analysis (EDAX), Fourier-transform infrared spectroscopy (FTIR) and corrosion resistance. The findings showed that Ti–Co–Cr-coated substrate at 3N load have good mechanical tolerance and offers admirable performance. The corrosion resistance of the specimens divulges the biocompatibility of Ti–Co–Cr as being more distinct because of the existence of titanium metal.
In this paper, an investigation on the behaviour of RC beams with circular openings in the flexural zone and shear zone strengthened using steel plates is presented. Totally seven beams were cast: a control beam, one beam with a circular opening of size of one‐third the depth of the beam (100 mmϕ) in the flexural zone, one beam with opening strengthened using the steel plate, one beam with a circular opening of size of 100 mmϕ in the shear zone, one beam with an opening in the shear zone strengthened using the steel plate, one beam with two circular openings of size of 100 mmϕ in the shear zone, and another beam with two openings in the shear zone strengthened using the steel plate. The experiments were conducted in a loading frame of 400 kN capacity. The beams were subjected to two‐point loading. The ultimate load carrying capacity reduced marginally by 1.78% and 2.8% compared to that of the control beam when a circular opening of 100 mmϕ was provided in the flexural zone and shear zone, respectively, and when the opening was strengthened with steel plates, it reduced by 3.04% and 25%, respectively, but the ductility increased when steel plates were provided. Beams with an opening of size of one‐third the depth of the beam (100 mmϕ) in the flexural zone strengthened with the steel plate can be provided, as the load carrying capacity is only marginally reduced compared to the control beam, and the ductility is more when compared with beams with unstrengthened openings.