We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 ppm is deduced.
In this Letter, we demonstrate a high-temperature stable polymer planar waveguide Bragg grating based on cyclo-olefin copolymers. The high glass transition temperature of the polymer material amounting to 178°C, in conjunction with a high-temperature stable UV-curable adhesive used to connect the polymer sensor to a standard single-mode fiber, enables temperature readings of up to 160°C while exhibiting a temperature sensitivity of . The reflected power of the Bragg wavelength remains constant up to a temperature of 130°C before declining at higher temperatures with an overall reduction of 2.5 dB at 160°C. However, decreasing temperature results in a complete recovery of the peak power, facilitating steam pressure sterilization (129°C, 0.17 MPa) of the polymer planar waveguide Bragg grating.
Embedded channel waveguide Bragg gratings are fabricated in the Ormocer® hybrid polymers OrmoComp®, OrmoCore, and OrmoClad by employing a single writing step technique based on phase mask technology and KrF excimer laser irradiation. All waveguide Bragg gratings exhibit well-defined reflection peaks within the telecom wavelengths range with peak heights of up to 35 dB and −3 dB-bandwidths of down to 95 pm. Furthermore, the dependency of the fabricated embedded channel waveguide Bragg gratings on changes of the temperature and relative humidity are investigated. Here, we found that the Bragg grating in OrmoComp® is significantly influenced by humidity variations, while the Bragg gratings in OrmoCore and OrmoClad exhibit linear and considerably high temperature sensitivities of up to −250 pm/ C and a linear dependency on the relative humidity in the range of −9 pm/%.
A newly developed concept for a miniaturized optical shape sensor is demonstrated. The sensor consists of a flexible polymer bending beam with two integrated optical waveguide Bragg gratings spatially staggered to each other. We report on the basic layout and the fabrication process and characterize the fundamental sensing response by an elaborate testing scheme. The polymer shape sensor reveals a pronounced spectral shift of the Bragg wavelength of several nanometers upon deformation with a distinct directionality. In conjunction with an undiscernible hysteresis, these results highlight the general applicability of the polymer Bragg grating-based bending beam as a shape sensor.