Poi Ngian Shek

Prof. Dr. Poi Ngian Shek

Associate Professor(Universiti Teknologi Malaysia)
+1

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMahdi Shariati
Mahdi Shariati
MMMohammad Saeed Mafipour
Mohammad Saeed Mafipour
PMPeyman Mehrabi
Peyman Mehrabi
ABAlireza Bahadori
Alireza Bahadori
YZYousef Zandi
Yousef Zandi
Poi Ngian ShekPoi Ngian Shek
Poi Ngian Shek
Channel shear connectors are known as an appropriate alternative for common shear connectors due to having a lower manufacturing cost and an easier installation process. The behavior of channel connectors is generally determined through conducting experiments. However, these experiments are not only costly but also time-consuming. Moreover, the impact of other parameters cannot be easily seen in the behavior of the connectors. This paper aims to investigate the application of a hybrid artificial neural network–particle swarm optimization (ANN-PSO) model in the behavior prediction of channel connectors embedded in normal and high-strength concrete (HSC). To generate the required data, an experimental project was conducted. Dimensions of the channel connectors and the compressive strength of concrete were adopted as the inputs of the model, and load and slip were predicted as the outputs. To evaluate the ANN-PSO model, an ANN model was also developed and tuned by a backpropagation (BP) learning algorithm. The results of the paper revealed that an ANN model could properly predict the behavior of channel connectors and eliminate the need for conducting costly experiments to some extent. In addition, in this case, the ANN-PSO model showed better performance than the ANN-BP model by resulting in superior performance indices.

17 October 2020 in Crystals
Verified
Journal Article
Open access
PDF file
mugahed amranmugahed amran
mugahed amran
YLYeong Huei Lee
Yeong Huei Lee
Nikolai Ivanovich VatinNikolai Ivanovich Vatin
Nikolai Ivanovich Vatin
Roman FediukRoman Fediuk
Roman Fediuk
Poi Ngian ShekPoi Ngian Shek
Poi Ngian Shek
Murali GunasekaranMurali Gunasekaran
Murali Gunasekaran
Foam concrete (FC) serves as an efficient construction material that combines well thermal insulation and structural properties. The studies of material characteristics, including the mechanical, physical, rheological, and functional properties of lightweight concrete, have been conducted rigorously. However, a lack of knowledge on the design efficiency of reinforced FC (RFC) was found in current research trends, compared to reinforced lightweight aggregate concrete. Therefore, this paper presents a review of the performance and adaption in structures for RFC. According to the code specifications, the feasibility investigation was preliminarily determined in structural use through the summary for the mechanical properties of FC of FC’s mechanical properties. For reinforced concrete design, a direct method of reduction factors is introduced to design lightweight aggregate concrete, which is also suggested to be adapted into a lightweight FC design. It was found that flexural shear behavior is a more complex theoretical analysis than flexure. However, a reduction factor of 0.75 was recommended for shear, torsion, and compression; meanwhile, 0.6 for flexural members. Serviceability limit states design should be applied, as the crack was found predominant in RFC design. The deflection controls were recommended as 0.7 by previous research. Research on RFC’s compression members, such as a column or load load-bearing wall, were rarely found. Thus, further study for validating a safe design of RFC applications in construction industries today is highly imperative.

1 January 2014 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
YLYeong Huei Lee
Yeong Huei Lee
CTCher Siang Tan
Cher Siang Tan
SMShahrin Mohammad
Shahrin Mohammad
MTMahmood Md Tahir
Mahmood Md Tahir
Poi Ngian ShekPoi Ngian Shek
Poi Ngian Shek
The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections. The performance of these connections in the design of cold-formed steel structures is discussed.

12 January 2022 in Gels
Verified
Journal Article
Open access
PDF file
RARayed Alyousef
Rayed Alyousef
Ahmed M. EbidAhmed M. Ebid
Ahmed M. Ebid
Ghasan HuseienGhasan Huseien
Ghasan Huseien
HMHossein Mohammadhosseini
Hossein Mohammadhosseini
HAHisham Alabduljabbar
Hisham Alabduljabbar
AMAbdeliazim Mustafa Mohamed
Abdeliazim Mustafa Mohamed
Various geopolymer mortars (GPMs) as concrete repairing materials have become effective owing to their eco-friendly properties. Geopolymer binders designed from agricultural and industrial wastes display interesting and useful mechanical performance. Based on this fact, this research (experimental) focuses on the feasibility of achieving a new GPM with improved mechanical properties and enhanced durability performance against the aggressive sulfuric acid and sulfate attacks. This new ternary blend of GPMs can be achieved by combining waste ceramic tiles (WCT), fly ash (FA) and ground blast furnace slag (GBFS) with appropriate proportions. These GPMs were designed from a high volume of WCT, FA, and GBFS to repair the damaged concretes existing in the construction sectors. Flexural strength, slant shear bond strength, and compatibility of the obtained GPMs were compared with the base or normal concrete (NC) before and after exposure to the aggressive environments. Tests including flexural four-point loading and thermal expansion coefficient were performed. These GPMs were prepared using a low concentration of alkaline activator solution with increasing levels of GBFS and FA replaced by WCT. The results showed that substitution of GBFS and FA by WCT in the GPMs could enhance their bond strength, mechanical characteristics, and durability performance when exposed to aggressive environments. In addition, with the increase in WCT contents from 50 to 70%, the bond strength performance of the GPMs was considerably enhanced under sulfuric acid and sulfate attack. The achieved GPMs were shown to be highly compatible with the concrete substrate and excellent binders for various civil engineering construction applications. It is affirmed that the proposed GPMs can efficiently be used as high-performance materials to repair damaged concrete surfaces.

1 March 2009 in Construction and Building Materials
Verified
Journal Article
Closed access
MTMahmood Md Tahir
Mahmood Md Tahir
Poi Ngian ShekPoi Ngian Shek
Poi Ngian Shek
ASArizu Sulaiman
Arizu Sulaiman
CTCher Siang Tan
Cher Siang Tan

1 January 2019 in Latin American Journal of Solids and Structures
Verified
Journal Article
Open access
PDF file
SBS. O. Bamaga
S. O. Bamaga
MTM. M. Tahir
M. M. Tahir
Poi Ngian ShekPoi Ngian Shek
Poi Ngian Shek
SMS. Mohamad
S. Mohamad
ASA. Sulaiman
A. Sulaiman
RAR. Aghlara
R. Aghlara
Cold-formed steel (CFS) construction is widely recognised as an important contributor to sustainability and green construction. Thus, the use of CFS construction is encouraged and had been advanced by innovations in its structural applications. One such innovation that has recently gained popularity is the use of CFS sections in composite construction. The researchers assembled two CFS C-lipped channels back to back to construct I-beam sections for testing. Innovative bracket shear connectors were also developed and inserted between concrete slabs and steel beams in order to provide composite action. The composite beams were drastically stronger and stiffer than non-composite beams. The experimental results were validated theoretically with a high level of correspondence. The proposed composite beams with CFS sections were found to be strong and stiff enough to be used in the construction industry.