Neonatal heart failure (HF) is a progressive disease caused by cardiovascular and non-cardiovascular abnormalities. The most common cause of neonatal HF is structural congenital heart disease, while neonatal cardiomyopathy represents the most common cause of HF in infants with a structurally normal heart. Neonatal cardiomyopathy is a group of diseases manifesting with various morphological and functional phenotypes that affect the heart muscle and alter cardiac performance at, or soon after birth. The clinical presentation of neonates with cardiomyopathy is varied, as are the possible causes of the condition and the severity of disease presentation. Echocardiography is the selected method of choice for diagnostic evaluation, follow-up and analysis of treatment results for cardiomyopathies in neonates. Advances in neonatal echocardiography now permit a more comprehensive assessment of cardiac performance that could not be previously achieved with conventional imaging. In this review, we discuss the current and emerging echocardiographic techniques that aid in the correct diagnostic and pathophysiological assessment of some of the most common etiologies of HF that occur in neonates with a structurally normal heart and acquired cardiomyopathy and we provide recommendations for using these techniques to optimize the management of neonate with HF.
There is a growing interest worldwide in using echocardiography in the neonatal unit to act as a complement to the clinical assessment of the hemodynamic status of premature and term infants. However, there is a wide variation in how this tool is implemented across many jurisdictions, the level of expertise, including the oversight of this practice. Over the last 5 years, three major expert consensus statements have been published to provide guidance to neonatologists performing echocardiography, with all recommending a structured training program and clinical governance system for quality assurance. Neonatal practice in Europe is very heterogeneous and the proximity of neonatal units to pediatric cardiology centers varies significantly. Currently, there is no overarching governance structure for training and accreditation in Europe. In this paper, we provide a brief description of the current training recommendations across several jurisdictions including Europe, North America, and Australia and describe the steps required to achieve a sustainable governance structure with the responsibility to provide accreditation to neonatologist performed echocardiography in Europe.
Early identification of infants requiring surfactant therapy improves outcomes. We evaluated the accuracy of delivery room lung ultrasound (LUS) to predict surfactant therapy in very- and extremely preterm infants. Infants born at <320/7 weeks were prospectively enrolled at 2 centres. LUS videos of both sides of the chest were obtained 5-10 minutes, 11-20 minutes, and 1-3 hours after birth. Clinicians were masked to the results of the LUS assessment and surfactant therapy was provided according to local guidelines. LUS videos were graded blinded to clinical data. Presence of unilateral type 1 ('whiteout') LUS or worse was considered test positive. Receiver Operating Characteristic (ROC) analysis compared the accuracy of LUS and an FiO2 threshold of 0.3 to predict subsequent surfactant therapy. Fifty-two infants with a median age of 276/7 weeks (IQR 260/7 to 286/7) were studied. Thirty infants (58%) received surfactant. Area under the ROC curve (AUC) for LUS at 5-10 minutes, 11-20 minutes and 1-3 hours was 0.78 (95% CI, 0.66-0.90), 0.76 (95% CI, 0.65-0.88) and 0.86 (95% CI, 0.75-0.97) respectively, outperforming FiO2 at the 5-10 minute timepoint (AUC 0.45, 95% CI 0.29-0.62, p = 0.001). At 11-20 minutes, LUS had a specificity of 95% (95% CI 77-100%) and sensitivity of 59% (95% CI, 39-77%) to predict surfactant therapy. All infants born at 23-276/7 weeks with LUS test positive received surfactant. Twenty-six infants (50%) had worsening of LUS grades on serial assessment. LUS in the delivery room and accurately predicts surfactant therapy in infants <320/7 weeks.
BACKGROUND AND PURPOSE: Brain growth in the early postnatal period following preterm birth has not been well described. This study of infants born at <30 weeks9 gestational age and without major brain injury aimed to accomplish the following: 1) assess the reproducibility of linear measures made from cranial ultrasonography, 2) evaluate brain growth using sequential cranial ultrasonography linear measures from birth to term-equivalent age, and 3) explore perinatal predictors of postnatal brain growth. MATERIALS AND METHODS: Participants comprised 144 infants born at <30 weeks9 gestational age at a single center between January 2011 and December 2013. Infants with major brain injury seen on cranial ultrasonography or congenital or chromosomal abnormalities were excluded. Brain tissue and fluid spaces were measured from cranial ultrasonography performed as part of routine clinical care. Brain growth was assessed in 3 time intervals: 27 days9 postnatal age. Data were analyzed using intraclass correlation coefficients and mixed-effects regression. RESULTS: A total of 429 scans were assessed for 144 infants. Several linear measures showed excellent reproducibility. All measures of brain tissue increased with postnatal age, except for the biparietal diameter, which decreased within the first postnatal week and increased thereafter. Gestational age of ≥28 weeks at birth was associated with slower growth of the biparietal diameter and ventricular width compared with gestational age of <28 weeks. Postnatal corticosteroid administration was associated with slower growth of the corpus callosum length, transcerebellar diameter, and vermis height. Sepsis and necrotizing enterocolitis were associated with slower growth of the transcerebellar diameter. CONCLUSIONS: Postnatal brain growth in infants born at <30 weeks9 gestational age can be evaluated using sequential linear measures made from routine cranial ultrasonography and is associated with perinatal predictors of long-term development.
19 August 2024 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Objective To determine the accuracy of pre-extubation lung ultrasound (LUS) to predict reintubation in preterm infants born <32 weeks’ gestation. Design Prospective diagnostic accuracy study. Setting Two neonatal intensive care units. Methods Anterior and lateral LUS was performed pre-extubation. The primary outcome was the accuracy of LUS scores (range 0–24) to predict reintubation within 72 hours. Secondary outcomes were accuracy in predicting (1) reintubation within 7 days, (2) reintubation stratified by postnatal age and (3) accuracy of lateral imaging only (range 0–12). Pre-specified subgroup analyses were performed in extremely preterm infants born <28 weeks’ gestation. Cut-off scores, sensitivities and specificities were calculated using receiver operating characteristic analysis and reported as area under the curves (AUCs). Results One hundred preterm infants with a mean (SD) gestational age of 27.4 (2.2) weeks and birth weight of 1059 (354) g were studied. Thirteen were subsequently reintubated. The AUC (95% CI) of the pre-extubation LUS score for predicting reintubation was 0.63 (0.45–0.80). Accuracy was greater in extremely preterm infants: AUC 0.70 (0.52–0.87) and excellent in infants who were 7 days of age. Lateral imaging alone demonstrated similar accuracy to scanning anterior and lateral regions. Conclusions In contrast to previous studies, LUS was not a strong predictor of reintubation in preterm infants. Accuracy is increased in extremely preterm infants. Future research should focus on infants at highest risk of extubation failure and consider simpler imaging protocols. Trial registration number Australian New Zealand Clinical Trials Registry: ACTRN12621001356853.
24 June 2022 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Background Effective lung protective ventilation requires reliable, real-time estimation of lung volume at the bedside. Neonatal clinicians lack a readily available imaging tool for this purpose. Objective To determine the ability of lung ultrasound (LUS) of the dependent region to detect real-time changes in lung volume, identify opening and closing pressures of the lung, and detect pulmonary hysteresis. Methods LUS was performed on preterm lambs (n=20) during in vivo mapping of the pressure-volume relationship of the respiratory system using the super-syringe method. Electrical impedance tomography was used to derive regional lung volumes. Images were blindly graded using an expanded scoring system. The scores were compared with total and regional lung volumes, and differences in LUS scores between pressure increments were calculated. Results Changes in LUS scores correlated moderately with changes in total lung volume (r=0.56, 95% CI 0.47-0.64, p<0.0001) and fairly with right whole (r=0.41, CI 0.30-0.51, p<0.0001), ventral (r=0.39, CI 0.28-0.49, p<0.0001), central (r=0.41, CI 0.31-0.52, p<0.0001) and dorsal (r=0.38, CI 0.27-0.49, p<0.0001) regional lung volumes. The pressure-volume relationship of the lung exhibited hysteresis in all lambs. LUS was able to detect hysteresis in 17 (85%) lambs. The greatest changes in LUS scores occurred at the opening and closing pressures. Conclusion LUS was able to detect large changes in total and regional lung volume in real time and correctly identified opening and closing pressures but lacked the precision to detect small changes in lung volume. Further work is needed to improve precision prior to translation to clinical practice.